Author: Cold Regions Research and Engineering Laboratory (U.S.)
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 28
Book Description
Evaluation of SW846 Method 8330 for Characterization of Sites Contaminated with Residues of High Explosives
Author: Cold Regions Research and Engineering Laboratory (U.S.)
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 28
Book Description
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 28
Book Description
Evaluation of SW846 Method 8330 for Characterization of Sites Contaminated with Residues of High Explosives
Author:
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 28
Book Description
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 28
Book Description
Site Characterization for Explosives Contamination at a Military Firing Range Impact Area
Author: Thomas F. Jenkins
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 52
Book Description
A study was conducted at the inland firing ranges at Fort Ord to determine the current levels of explosives residues and to recommend appropriate future site characterization techniques. A set of 280 soil samples was collected from depths ranging from 0-15 cm to 105-120 cm from anti-tank ranges 44 and 48. Sampling locations were selected on the basis of the locations of current and former targets, and included an area away from specific targets and a background area, not affected by local detonations. HMX was the explosives residue present at the highest concentration. Much lower concentrations of RDX, TNT, and two isomers of aminodinitrotoluene were also detected. Explosives residues were largely confined to surface soils near tank targets. A major problem for site characterization was found to be the large spatial heterogeneity present. Composite samples very effectively provided representative samples for 5- x 5-m size grids. A colorimetric on-site method gave reliable results for HMX, relative to SW846 Method 8330. No currently available on-site method for RDX was found to be adequate in the presence of much higher concentrations of HMX.
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 52
Book Description
A study was conducted at the inland firing ranges at Fort Ord to determine the current levels of explosives residues and to recommend appropriate future site characterization techniques. A set of 280 soil samples was collected from depths ranging from 0-15 cm to 105-120 cm from anti-tank ranges 44 and 48. Sampling locations were selected on the basis of the locations of current and former targets, and included an area away from specific targets and a background area, not affected by local detonations. HMX was the explosives residue present at the highest concentration. Much lower concentrations of RDX, TNT, and two isomers of aminodinitrotoluene were also detected. Explosives residues were largely confined to surface soils near tank targets. A major problem for site characterization was found to be the large spatial heterogeneity present. Composite samples very effectively provided representative samples for 5- x 5-m size grids. A colorimetric on-site method gave reliable results for HMX, relative to SW846 Method 8330. No currently available on-site method for RDX was found to be adequate in the presence of much higher concentrations of HMX.
CRREL Report
Author:
Publisher:
ISBN:
Category : Cold regions
Languages : en
Pages : 486
Book Description
Publisher:
ISBN:
Category : Cold regions
Languages : en
Pages : 486
Book Description
Coulometric Electrode Array Detectors for HPLC
Author: I.H. Acworth
Publisher: CRC Press
ISBN: 1466563710
Category : Science
Languages : en
Pages : 393
Book Description
This sixth volume in the book series Progress in HPLC-HPCE examines the enhancement of high- performance liquid chromatography through the development of an advanced mode of electrochemical detection (ECD) --- the coulometric array detection --- from its initial, yet problematic, amperometric (thin-layer) design to the highly sensitive, selective and stable coulometric (flow-through) design. Unlike amperometric electrodes, the coulometric electrode is 100% efficient and measures signals from all of the analyte passing through it, which leads to improved sensitivity as well as unique selectivity. The coulometric electrode array offers the resolution of the photodiode array with the extreme sensitivity of an electrochemical detector.
Publisher: CRC Press
ISBN: 1466563710
Category : Science
Languages : en
Pages : 393
Book Description
This sixth volume in the book series Progress in HPLC-HPCE examines the enhancement of high- performance liquid chromatography through the development of an advanced mode of electrochemical detection (ECD) --- the coulometric array detection --- from its initial, yet problematic, amperometric (thin-layer) design to the highly sensitive, selective and stable coulometric (flow-through) design. Unlike amperometric electrodes, the coulometric electrode is 100% efficient and measures signals from all of the analyte passing through it, which leads to improved sensitivity as well as unique selectivity. The coulometric electrode array offers the resolution of the photodiode array with the extreme sensitivity of an electrochemical detector.
Monthly Catalog of United States Government Publications
Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1168
Book Description
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1168
Book Description
Monthly Catalogue, United States Public Documents
Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1208
Book Description
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1208
Book Description
Special Report
Author:
Publisher:
ISBN:
Category : Arctic regions
Languages : en
Pages : 28
Book Description
Publisher:
ISBN:
Category : Arctic regions
Languages : en
Pages : 28
Book Description
Evaluation of Clean Solid Phases for Extraction of Nitroaromatics and Nitramines from Water
Author:
Publisher:
ISBN:
Category : Groundwater
Languages : en
Pages : 28
Book Description
Publisher:
ISBN:
Category : Groundwater
Languages : en
Pages : 28
Book Description
Biological Remediation of Explosive Residues
Author: Shree Nath Singh
Publisher: Springer Science & Business Media
ISBN: 3319010832
Category : Science
Languages : en
Pages : 406
Book Description
Microbial degradation, Phytoremediation, Remediation, Explosive residues, Biotransformation, Mineralization, Degradative Enzymes, Degradation Pathways, Energetics, Soil contamination, Water contamination.
Publisher: Springer Science & Business Media
ISBN: 3319010832
Category : Science
Languages : en
Pages : 406
Book Description
Microbial degradation, Phytoremediation, Remediation, Explosive residues, Biotransformation, Mineralization, Degradative Enzymes, Degradation Pathways, Energetics, Soil contamination, Water contamination.