Author: Thomas D. Ballard
Publisher:
ISBN:
Category :
Languages : en
Pages : 152
Book Description
Hydrostatic Weighing at Total Lung Capacity Versus Residual Volume
Author: Thomas D. Ballard
Publisher:
ISBN:
Category :
Languages : en
Pages : 152
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages : 152
Book Description
Hydrostatic Weighing Using Total Lung Capacity and Residual Volume
Author: Kenny Owens
Publisher:
ISBN:
Category : Body weight
Languages : en
Pages : 132
Book Description
Publisher:
ISBN:
Category : Body weight
Languages : en
Pages : 132
Book Description
Comparison of Hydrostatic Weighing at Residual Volume and Total Lung Capacity in Boys
Author: Mary J. DeLisio
Publisher:
ISBN:
Category : Adipose tissues
Languages : en
Pages : 110
Book Description
This study was designed to determine if hydrostatic weighing (HW) at total lung capacity (TLC) yield the same results as HW at residual volume (RV). Forty-two boys (i = 10.4 y r) from the La Crosse, WI, area were given a spirometry test to determine their vital capacity (VC). Three trials were performed and the highest reading was used as the measure of VC. The RV was determined on land utilizing the closed circuit oxygen dilution technique. This value was added t o the VC measurement and represented the SS' TLC. SS were instructed to perform HW at RV and TLC. The RV method consisted of a full expiration prior to submersion, and was performed until 3 identical readings were attained. The TLC consisted of a full inspiration prior to submersion, and was performed until 3 identical readings were reached. A dependent t-test was performed on these data at the,05 level. Small but statistical diff (p
Publisher:
ISBN:
Category : Adipose tissues
Languages : en
Pages : 110
Book Description
This study was designed to determine if hydrostatic weighing (HW) at total lung capacity (TLC) yield the same results as HW at residual volume (RV). Forty-two boys (i = 10.4 y r) from the La Crosse, WI, area were given a spirometry test to determine their vital capacity (VC). Three trials were performed and the highest reading was used as the measure of VC. The RV was determined on land utilizing the closed circuit oxygen dilution technique. This value was added t o the VC measurement and represented the SS' TLC. SS were instructed to perform HW at RV and TLC. The RV method consisted of a full expiration prior to submersion, and was performed until 3 identical readings were attained. The TLC consisted of a full inspiration prior to submersion, and was performed until 3 identical readings were reached. A dependent t-test was performed on these data at the,05 level. Small but statistical diff (p
Analysis of Hydrostatic Weighing at Residual Volume and Two Determinations of Total Lung Capacity
Author: Glenn Sheffield
Publisher:
ISBN:
Category : Body composition
Languages : en
Pages : 124
Book Description
Publisher:
ISBN:
Category : Body composition
Languages : en
Pages : 124
Book Description
A Comparison of Hydrostatic Weighing at Total Lung Capacity and Residual Volume
Author: Robert George Morgan
Publisher:
ISBN:
Category : Body weight
Languages : en
Pages : 108
Book Description
Publisher:
ISBN:
Category : Body weight
Languages : en
Pages : 108
Book Description
Measurement of Body Density by Hydrostatic Weighing at Residual Volume and Total Lung Capacity
Author: Jerry L. Coffman
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
A Comparison of Body Density and Percent Body Fat as Computed Using Four Different Lung Volumes in the Hydrostatic Weighing Technique
Author: Dean Witherspoon
Publisher:
ISBN:
Category : Human body
Languages : en
Pages : 132
Book Description
This study compared body density (BD) and percent body fat (%BF) arrived at by using four different lung volumes in the hydrostatic weighing (HW) procedure. The four lung volumes were residual volume as measured in air (RV-dry), residual volume as measured immersed in water (RV-wet), functional residual capacity, as measured immersed (FRC), and total lung capacity as measured immersed (TLC). The closed circuit oxygen dilution technique was used to measure all lung volumes.
Publisher:
ISBN:
Category : Human body
Languages : en
Pages : 132
Book Description
This study compared body density (BD) and percent body fat (%BF) arrived at by using four different lung volumes in the hydrostatic weighing (HW) procedure. The four lung volumes were residual volume as measured in air (RV-dry), residual volume as measured immersed in water (RV-wet), functional residual capacity, as measured immersed (FRC), and total lung capacity as measured immersed (TLC). The closed circuit oxygen dilution technique was used to measure all lung volumes.
A Comparison of Three Hydrostatic Weighing Techniques: Without Head Submersion, Total Lung Capacity, and Residual Volume
Author: Kwai Ming Wa
Publisher:
ISBN:
Category : Adipose tissues
Languages : en
Pages : 278
Book Description
Abstract: The purpose of this study was to compare the without head submersion (HWNHS) and total lung capacity (HWTLC) hydrostatic weighing techniques to the criterion measure of hydrostatic weighing at residual volume (HWRV). Subjects were 54 healthy males. In an attempt to improve the accuracy of HWNHS, regression analysis was used to predict actual head volume from spherical head volume (R2 = .27, standard error of estimate (SEE) = 42 6 mL). Predicted head volume was then added to total body volume (TBV) determined by HWNHS. TBV for all three techniques was corrected by subtracting the appropriate lung and gastro-intestinal volumes. Mean body density (Db) was 1.065 g/mL, 1.072 g/mL, and 1.072 g/mL for HWRV, HWTLC, and HWNHS, respectively. Mean percent body fat (% fat) was 15.10%, 11.85%, and 11.89% for HWRV, HWTLC, and HWNHS, respectively. Significant differences in mean Db and % fat were observed, with HWTLC and HWNHS overestimating Db and underestimating % fat from HWRV. Although correlations between the three hydrostatic weighing techniques were greater than .85, the SEEs for predicting % fat measured by HWRV were 3.49% and 3.25% for HWTLC and HWNHS, respectively.
Publisher:
ISBN:
Category : Adipose tissues
Languages : en
Pages : 278
Book Description
Abstract: The purpose of this study was to compare the without head submersion (HWNHS) and total lung capacity (HWTLC) hydrostatic weighing techniques to the criterion measure of hydrostatic weighing at residual volume (HWRV). Subjects were 54 healthy males. In an attempt to improve the accuracy of HWNHS, regression analysis was used to predict actual head volume from spherical head volume (R2 = .27, standard error of estimate (SEE) = 42 6 mL). Predicted head volume was then added to total body volume (TBV) determined by HWNHS. TBV for all three techniques was corrected by subtracting the appropriate lung and gastro-intestinal volumes. Mean body density (Db) was 1.065 g/mL, 1.072 g/mL, and 1.072 g/mL for HWRV, HWTLC, and HWNHS, respectively. Mean percent body fat (% fat) was 15.10%, 11.85%, and 11.89% for HWRV, HWTLC, and HWNHS, respectively. Significant differences in mean Db and % fat were observed, with HWTLC and HWNHS overestimating Db and underestimating % fat from HWRV. Although correlations between the three hydrostatic weighing techniques were greater than .85, the SEEs for predicting % fat measured by HWRV were 3.49% and 3.25% for HWTLC and HWNHS, respectively.
Comparison of Hydrostatic Weights Using Residual Volume and Total Lung Capacity
Author: Pat Lundvall
Publisher:
ISBN:
Category :
Languages : en
Pages : 176
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages : 176
Book Description
A Comparison of Body Density Determinations Using Residual Volume and Total Lung Capacity in Underwater Weighing Technique
Author: Chi Shing Lee
Publisher:
ISBN:
Category : Body composition
Languages : en
Pages : 114
Book Description
Publisher:
ISBN:
Category : Body composition
Languages : en
Pages : 114
Book Description