Author: Natarajan Manivasakam
Publisher:
ISBN: 9780820601717
Category : Boilers
Languages : en
Pages : 0
Book Description
PARTIAL CONTENTS - PART - I. BOILER BASICS - Chapter 1. Boiler - An Introduction - Chapter 2. Classification of Boilers - Chapter 3. Common Terms and Explanation - PART - II. BOILER WATER TROUBLES - Chapter 4. Impurities in Water and Their Effects - Chapter 5. Boiler Water Troubles - A Prelude - Chapter 6. Scale Formation - Chapter 7. Silica Carryover - Chapter 8. Scale Formation in Economizers - Chapter 9. Super Heater and Turbine Deposits - Chapter 10. Corrosion - Basic Information - Chapter 11. General Corrosion (Overall Corrosion / Acidic Corrosion) - Chapter 12. Dissolved Oxygen Corrosion (Pitting Corrosion) - Chapter 13. Carbondioxide Corrosion - Chapter 14. Corrosion caused by Unstable Salts - Chapter 15. Corrosion caused by Other Substances - Chapter 16. Corrosion caused by Chelants (Chelant Corrosion) - Chapter 17. Caustic Embrittlement and Caustic Gouging - Chapter 18. Hydrogen Embrittlement - Chapter 19. Condensate Corrosion - Chapter 20. Preboiler Corrosion - Chapter 21. Economizer Corrosion - Chapter 22. Super Heater and Turbine Corrosion - Chapter 23. Foaming, Priming & Carryover - PART - III. WATER QUALITY REQUIREMENTS AND TREATMENT PROGRAMS - Chapter 24. Quality Requirements for Feed Water and Boiler Water - Chapter 25. Objectives of Boiler Water Treatment - Chapter 26. External Treatment and Internal Treatment - Chapter 27. Water Treatment programs - Guidelines - PART - IV. EXTERNAL TREATMENT - Chapter 28. External Treatment - A Prelude - Chapter 29. Coagulation (Removal of Color, Turbidity and Suspended Matter) - Chapter 30. Filtration - Chapter 31. Softening by Chemical Method (Lime - Soda Softening) - Chapter 32. Ion Exchange Resins and Treatment Methods - Chapter 33. Softening by Ion-Exchange Method - Chapter 34. Dealkalization - Chapter 35. Demineralization (Deionization) - Chapter 36. Mixed Bed Deionization - Chapter 37. Reverse Osmosis - Chapter 38. Evaporation - Chapter 39. Silica Removal - Chapter 40. Oil Removal - Chapter 41. Condensate Treatment (Condensate Polishing) - Chapter 42. Deaeration (Mechanical Removal of Oxygen) - PART - V. INTERNAL TREATMENT - Chapter 43. Internal Boiler Water Treatment - A Prelude - Chapter 44. Organic Polymers and Their Role as Scale Inhibitors, Dispersants and Sludge Conditioners in Boiler Water Treatment - Chapter 45. Internal Treatment - Chemical Feeding - Chapter 46. Prevention of Scale Formation - Chapter 47. Sludge Conditioning - Chapter 48. Prevention of Corrosion - An Introduction - Chapter 49. Prevention of Corrosion Due to Low pH - Chapter 50. Prevention of Pitting Corrosion Using Oxygen Scavengers (Chemical Removal of Oxygen) - Chapter 51. Prevention of Caustic Embrittlement and Caustic Gouging - Chapter 52. Prevention of Chelant Corrosion - Chapter 53. Prevention of Condensate Corrosion - Chapter 54. Prevention of Pre-Boiler Corrosion - Chapter 55. Prevention of Economizer Corrosion - Chapter 56. Prevention of Foaming, Priming & Carryover - Chapter 57. Prevention of Silica Carryover - Chapter 58. Boiler Blow Down - PART - VI. BOILER WATER TREATMENT - IMPORTANT CALCULATIONS - Chapter 59. Basic Conversion Factors - Chapter 60. Water Softening - Calculations - Chapter 61. Cycles of Concentration, Blowdown, Feed Water and Makeup Water - Calculations - Chapter 62. Determination of Dosage of Chemicals - PART - VII. BOILER START UP, CLEANING, LAY UP AND MAINTENANCE - Chapter 63. Boiler Startup (Pre-operational Cleaning) - Chapter 64. Descaling and Boiler Cleaning - Chapter 65. Boiler LayUp - Chapter 66. Boiler Maintenance - PART - VIII. CHEMICALS HANDLING, SOLUTION PREPARATION AND FEEDERS - Chapter 67. Chemicals Handling and Storage - Chapter 68. Preparation of Solutions and Suspensions - Chapter 69. Chemical Feeders - PART - IX. ANALYSIS OF WATER AND STEAM - See Website for full TOC
Practical Boiler Water Treatment Handbook
Author: Natarajan Manivasakam
Publisher:
ISBN: 9780820601717
Category : Boilers
Languages : en
Pages : 0
Book Description
PARTIAL CONTENTS - PART - I. BOILER BASICS - Chapter 1. Boiler - An Introduction - Chapter 2. Classification of Boilers - Chapter 3. Common Terms and Explanation - PART - II. BOILER WATER TROUBLES - Chapter 4. Impurities in Water and Their Effects - Chapter 5. Boiler Water Troubles - A Prelude - Chapter 6. Scale Formation - Chapter 7. Silica Carryover - Chapter 8. Scale Formation in Economizers - Chapter 9. Super Heater and Turbine Deposits - Chapter 10. Corrosion - Basic Information - Chapter 11. General Corrosion (Overall Corrosion / Acidic Corrosion) - Chapter 12. Dissolved Oxygen Corrosion (Pitting Corrosion) - Chapter 13. Carbondioxide Corrosion - Chapter 14. Corrosion caused by Unstable Salts - Chapter 15. Corrosion caused by Other Substances - Chapter 16. Corrosion caused by Chelants (Chelant Corrosion) - Chapter 17. Caustic Embrittlement and Caustic Gouging - Chapter 18. Hydrogen Embrittlement - Chapter 19. Condensate Corrosion - Chapter 20. Preboiler Corrosion - Chapter 21. Economizer Corrosion - Chapter 22. Super Heater and Turbine Corrosion - Chapter 23. Foaming, Priming & Carryover - PART - III. WATER QUALITY REQUIREMENTS AND TREATMENT PROGRAMS - Chapter 24. Quality Requirements for Feed Water and Boiler Water - Chapter 25. Objectives of Boiler Water Treatment - Chapter 26. External Treatment and Internal Treatment - Chapter 27. Water Treatment programs - Guidelines - PART - IV. EXTERNAL TREATMENT - Chapter 28. External Treatment - A Prelude - Chapter 29. Coagulation (Removal of Color, Turbidity and Suspended Matter) - Chapter 30. Filtration - Chapter 31. Softening by Chemical Method (Lime - Soda Softening) - Chapter 32. Ion Exchange Resins and Treatment Methods - Chapter 33. Softening by Ion-Exchange Method - Chapter 34. Dealkalization - Chapter 35. Demineralization (Deionization) - Chapter 36. Mixed Bed Deionization - Chapter 37. Reverse Osmosis - Chapter 38. Evaporation - Chapter 39. Silica Removal - Chapter 40. Oil Removal - Chapter 41. Condensate Treatment (Condensate Polishing) - Chapter 42. Deaeration (Mechanical Removal of Oxygen) - PART - V. INTERNAL TREATMENT - Chapter 43. Internal Boiler Water Treatment - A Prelude - Chapter 44. Organic Polymers and Their Role as Scale Inhibitors, Dispersants and Sludge Conditioners in Boiler Water Treatment - Chapter 45. Internal Treatment - Chemical Feeding - Chapter 46. Prevention of Scale Formation - Chapter 47. Sludge Conditioning - Chapter 48. Prevention of Corrosion - An Introduction - Chapter 49. Prevention of Corrosion Due to Low pH - Chapter 50. Prevention of Pitting Corrosion Using Oxygen Scavengers (Chemical Removal of Oxygen) - Chapter 51. Prevention of Caustic Embrittlement and Caustic Gouging - Chapter 52. Prevention of Chelant Corrosion - Chapter 53. Prevention of Condensate Corrosion - Chapter 54. Prevention of Pre-Boiler Corrosion - Chapter 55. Prevention of Economizer Corrosion - Chapter 56. Prevention of Foaming, Priming & Carryover - Chapter 57. Prevention of Silica Carryover - Chapter 58. Boiler Blow Down - PART - VI. BOILER WATER TREATMENT - IMPORTANT CALCULATIONS - Chapter 59. Basic Conversion Factors - Chapter 60. Water Softening - Calculations - Chapter 61. Cycles of Concentration, Blowdown, Feed Water and Makeup Water - Calculations - Chapter 62. Determination of Dosage of Chemicals - PART - VII. BOILER START UP, CLEANING, LAY UP AND MAINTENANCE - Chapter 63. Boiler Startup (Pre-operational Cleaning) - Chapter 64. Descaling and Boiler Cleaning - Chapter 65. Boiler LayUp - Chapter 66. Boiler Maintenance - PART - VIII. CHEMICALS HANDLING, SOLUTION PREPARATION AND FEEDERS - Chapter 67. Chemicals Handling and Storage - Chapter 68. Preparation of Solutions and Suspensions - Chapter 69. Chemical Feeders - PART - IX. ANALYSIS OF WATER AND STEAM - See Website for full TOC
Publisher:
ISBN: 9780820601717
Category : Boilers
Languages : en
Pages : 0
Book Description
PARTIAL CONTENTS - PART - I. BOILER BASICS - Chapter 1. Boiler - An Introduction - Chapter 2. Classification of Boilers - Chapter 3. Common Terms and Explanation - PART - II. BOILER WATER TROUBLES - Chapter 4. Impurities in Water and Their Effects - Chapter 5. Boiler Water Troubles - A Prelude - Chapter 6. Scale Formation - Chapter 7. Silica Carryover - Chapter 8. Scale Formation in Economizers - Chapter 9. Super Heater and Turbine Deposits - Chapter 10. Corrosion - Basic Information - Chapter 11. General Corrosion (Overall Corrosion / Acidic Corrosion) - Chapter 12. Dissolved Oxygen Corrosion (Pitting Corrosion) - Chapter 13. Carbondioxide Corrosion - Chapter 14. Corrosion caused by Unstable Salts - Chapter 15. Corrosion caused by Other Substances - Chapter 16. Corrosion caused by Chelants (Chelant Corrosion) - Chapter 17. Caustic Embrittlement and Caustic Gouging - Chapter 18. Hydrogen Embrittlement - Chapter 19. Condensate Corrosion - Chapter 20. Preboiler Corrosion - Chapter 21. Economizer Corrosion - Chapter 22. Super Heater and Turbine Corrosion - Chapter 23. Foaming, Priming & Carryover - PART - III. WATER QUALITY REQUIREMENTS AND TREATMENT PROGRAMS - Chapter 24. Quality Requirements for Feed Water and Boiler Water - Chapter 25. Objectives of Boiler Water Treatment - Chapter 26. External Treatment and Internal Treatment - Chapter 27. Water Treatment programs - Guidelines - PART - IV. EXTERNAL TREATMENT - Chapter 28. External Treatment - A Prelude - Chapter 29. Coagulation (Removal of Color, Turbidity and Suspended Matter) - Chapter 30. Filtration - Chapter 31. Softening by Chemical Method (Lime - Soda Softening) - Chapter 32. Ion Exchange Resins and Treatment Methods - Chapter 33. Softening by Ion-Exchange Method - Chapter 34. Dealkalization - Chapter 35. Demineralization (Deionization) - Chapter 36. Mixed Bed Deionization - Chapter 37. Reverse Osmosis - Chapter 38. Evaporation - Chapter 39. Silica Removal - Chapter 40. Oil Removal - Chapter 41. Condensate Treatment (Condensate Polishing) - Chapter 42. Deaeration (Mechanical Removal of Oxygen) - PART - V. INTERNAL TREATMENT - Chapter 43. Internal Boiler Water Treatment - A Prelude - Chapter 44. Organic Polymers and Their Role as Scale Inhibitors, Dispersants and Sludge Conditioners in Boiler Water Treatment - Chapter 45. Internal Treatment - Chemical Feeding - Chapter 46. Prevention of Scale Formation - Chapter 47. Sludge Conditioning - Chapter 48. Prevention of Corrosion - An Introduction - Chapter 49. Prevention of Corrosion Due to Low pH - Chapter 50. Prevention of Pitting Corrosion Using Oxygen Scavengers (Chemical Removal of Oxygen) - Chapter 51. Prevention of Caustic Embrittlement and Caustic Gouging - Chapter 52. Prevention of Chelant Corrosion - Chapter 53. Prevention of Condensate Corrosion - Chapter 54. Prevention of Pre-Boiler Corrosion - Chapter 55. Prevention of Economizer Corrosion - Chapter 56. Prevention of Foaming, Priming & Carryover - Chapter 57. Prevention of Silica Carryover - Chapter 58. Boiler Blow Down - PART - VI. BOILER WATER TREATMENT - IMPORTANT CALCULATIONS - Chapter 59. Basic Conversion Factors - Chapter 60. Water Softening - Calculations - Chapter 61. Cycles of Concentration, Blowdown, Feed Water and Makeup Water - Calculations - Chapter 62. Determination of Dosage of Chemicals - PART - VII. BOILER START UP, CLEANING, LAY UP AND MAINTENANCE - Chapter 63. Boiler Startup (Pre-operational Cleaning) - Chapter 64. Descaling and Boiler Cleaning - Chapter 65. Boiler LayUp - Chapter 66. Boiler Maintenance - PART - VIII. CHEMICALS HANDLING, SOLUTION PREPARATION AND FEEDERS - Chapter 67. Chemicals Handling and Storage - Chapter 68. Preparation of Solutions and Suspensions - Chapter 69. Chemical Feeders - PART - IX. ANALYSIS OF WATER AND STEAM - See Website for full TOC
Boiler Feed Water Purification
Author: Sheppard T. Powell
Publisher:
ISBN:
Category : Feed-water purification
Languages : en
Pages : 384
Book Description
Publisher:
ISBN:
Category : Feed-water purification
Languages : en
Pages : 384
Book Description
The Chemical Treatment of Boiler Water
Author: James W. McCoy
Publisher: Chemical Publishing Company
ISBN: 9780820603773
Category : Science
Languages : en
Pages : 0
Book Description
Those involved in the design, operation, or maintenance of industrial boilers will find this book an invaluable source of information. First the author discusses the relationship between boilers and the generated steam. The prevention of scaling, corrosion, stress corrosion cracking, and steam contamination are fully explored followed by an in-depth examination of the chemical treatments necessary to implement preventative measures. Specific types of boilers are discussed, water treatment programs and operating guidelines are outlined. Finally, step-by-step procedures are given for testing boiler water for the various contaminants. The clarity and accuracy of presentation allows this book to function as a manual as well as a text. CONTENTS: Principles of Steam Generation; Objectives in Treating Water for Boilers; Physical methods for Improving Water Quality; External Chemical Treatments; Internal Chemical Treatments; Operating Procedures; Complications in the Operation of Boilers: Analytical Methods;
Publisher: Chemical Publishing Company
ISBN: 9780820603773
Category : Science
Languages : en
Pages : 0
Book Description
Those involved in the design, operation, or maintenance of industrial boilers will find this book an invaluable source of information. First the author discusses the relationship between boilers and the generated steam. The prevention of scaling, corrosion, stress corrosion cracking, and steam contamination are fully explored followed by an in-depth examination of the chemical treatments necessary to implement preventative measures. Specific types of boilers are discussed, water treatment programs and operating guidelines are outlined. Finally, step-by-step procedures are given for testing boiler water for the various contaminants. The clarity and accuracy of presentation allows this book to function as a manual as well as a text. CONTENTS: Principles of Steam Generation; Objectives in Treating Water for Boilers; Physical methods for Improving Water Quality; External Chemical Treatments; Internal Chemical Treatments; Operating Procedures; Complications in the Operation of Boilers: Analytical Methods;
Reverse Osmosis and Nanofiltration, (M46)
Author: AWWA Staff
Publisher: American Water Works Association
ISBN: 1613000332
Category : Drinking water
Languages : en
Pages : 240
Book Description
Publisher: American Water Works Association
ISBN: 1613000332
Category : Drinking water
Languages : en
Pages : 240
Book Description
Calcium Phosphates in Biological and Industrial Systems
Author: Zahid Amjad
Publisher: Springer Science & Business Media
ISBN: 1461555175
Category : Technology & Engineering
Languages : en
Pages : 509
Book Description
Calcium Phosphates in Biological and Industrial Systems provides a comprehensive discussion on calcium phosphates in the diverse areas of their applications. The authors are all respected specialists in their particular fields, possessing wide knowledge and experience and able to analyze recent results and relate them to their respective areas of expertise. New information, as well as a review of current concepts, highlights the individual contributions. Due to the broad scope of the subject covered and the large number of contributions, this book is divided into three parts. Whilst each section contains a basic theme, there is a considerable overlapping of ideas and approaches. This reflects the excitement and interdisciplinary nature of investigations by researchers interested in dissimilar aspects of calcium phosphates. Considering the general interest in calcium phosphates, Calcium Phosphates in Biological and Industrial Systems is directed at an audience of researchers in the fields of biology, chemistry, dentistry, geology, chemical engineering, environmental engineering, and medicine. It will also be useful to technology-focused researchers in industry whose investigations might be related directly or indirectly to calcium phosphates.
Publisher: Springer Science & Business Media
ISBN: 1461555175
Category : Technology & Engineering
Languages : en
Pages : 509
Book Description
Calcium Phosphates in Biological and Industrial Systems provides a comprehensive discussion on calcium phosphates in the diverse areas of their applications. The authors are all respected specialists in their particular fields, possessing wide knowledge and experience and able to analyze recent results and relate them to their respective areas of expertise. New information, as well as a review of current concepts, highlights the individual contributions. Due to the broad scope of the subject covered and the large number of contributions, this book is divided into three parts. Whilst each section contains a basic theme, there is a considerable overlapping of ideas and approaches. This reflects the excitement and interdisciplinary nature of investigations by researchers interested in dissimilar aspects of calcium phosphates. Considering the general interest in calcium phosphates, Calcium Phosphates in Biological and Industrial Systems is directed at an audience of researchers in the fields of biology, chemistry, dentistry, geology, chemical engineering, environmental engineering, and medicine. It will also be useful to technology-focused researchers in industry whose investigations might be related directly or indirectly to calcium phosphates.
Boiler Feed Water Treatment
Author: F. J. Matthews
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 246
Book Description
Contents - PART 1. NATURAL WATER SUPPLIES - Rain water - Surface water - River water - Spring water - Well water - Canal water - Pit water - Effects of drought - Condensate as feed water - Water blending - PART 2. SCALE FORMATION - Effect of scale - Lime-soda process - Hot lime-soda softening - General notes on plant - Nuclear precipitation - Caustic soda softening - Sodium aluminate with lime-soda treatment - Zeolite or base-exchange softeners - Partial Zeolite softening - Hydrogen and demineralizing zeolites - Lime-base exchange treatment - The B.B.A. dejector - Lime-Barium softeners - Necessity for conditioning boiler feed - Colloidal conditioning- Mechanism of scale formation - Carbonate and phosphate conditioning - Use of metaphosphate and pyrophosphate - Budenheim phosphate treatment - Silica scales and deposits - Turbine blade deposits - Potassium treatment - Chlorination of condenser cooling water - Scale formation in cooling water systems - Scale formation in economizers - Electrical scale prevention - Removal of scales and deposits - PART 3. CORROSION - Early theories of corrosion- Corrosion by differential aeration - Dissolved oxygen Deaeration by chemical methods - Deaeration by physical methods - Corrosion due to unstable salts - Danger of soft water Corrosion by carbon dioxide - Superheater and turbine corrosion - Economizer corrosion- The treatment of alkaline waters - Caustic embrittlement - Hydrogen ion concentration - Determination of pH values - Hydrogen ions and corrosion - Coagulation control - Softening plant control - Boiler water recirculation - Electrical methods of preventing corrosion - PART 4. FOAMING AND PRIMING - Causes of priming - Balanced layer film formation - Foam stabilization - Prevention of priming - Blow-down control - Intermittent blow-down - Continuous blow-down systems - Use of condensate and blending of waters - Removal of oil from water - Methods of de-oiling water - PART 5. ANALYSIS AND ROUTINE TESTING - Sampling- Standard solutions - Frequency of analyses - Units - Control tests for softening - Raw water - Chemicals required for treatment - Control tests for softening - Treated water - Tests for carbonate and phosphate conditioning - Dissolved oxygen - Blow-down testing - Embrittlement ratios - General water analysis - Analysis of scales- Residual chlorine - Tannins - Appendix - Index - Standard solutions - Reagents-Clark's table of hardnesses - Chemical factors - Conversion tables - Summary of recommended practice -
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 246
Book Description
Contents - PART 1. NATURAL WATER SUPPLIES - Rain water - Surface water - River water - Spring water - Well water - Canal water - Pit water - Effects of drought - Condensate as feed water - Water blending - PART 2. SCALE FORMATION - Effect of scale - Lime-soda process - Hot lime-soda softening - General notes on plant - Nuclear precipitation - Caustic soda softening - Sodium aluminate with lime-soda treatment - Zeolite or base-exchange softeners - Partial Zeolite softening - Hydrogen and demineralizing zeolites - Lime-base exchange treatment - The B.B.A. dejector - Lime-Barium softeners - Necessity for conditioning boiler feed - Colloidal conditioning- Mechanism of scale formation - Carbonate and phosphate conditioning - Use of metaphosphate and pyrophosphate - Budenheim phosphate treatment - Silica scales and deposits - Turbine blade deposits - Potassium treatment - Chlorination of condenser cooling water - Scale formation in cooling water systems - Scale formation in economizers - Electrical scale prevention - Removal of scales and deposits - PART 3. CORROSION - Early theories of corrosion- Corrosion by differential aeration - Dissolved oxygen Deaeration by chemical methods - Deaeration by physical methods - Corrosion due to unstable salts - Danger of soft water Corrosion by carbon dioxide - Superheater and turbine corrosion - Economizer corrosion- The treatment of alkaline waters - Caustic embrittlement - Hydrogen ion concentration - Determination of pH values - Hydrogen ions and corrosion - Coagulation control - Softening plant control - Boiler water recirculation - Electrical methods of preventing corrosion - PART 4. FOAMING AND PRIMING - Causes of priming - Balanced layer film formation - Foam stabilization - Prevention of priming - Blow-down control - Intermittent blow-down - Continuous blow-down systems - Use of condensate and blending of waters - Removal of oil from water - Methods of de-oiling water - PART 5. ANALYSIS AND ROUTINE TESTING - Sampling- Standard solutions - Frequency of analyses - Units - Control tests for softening - Raw water - Chemicals required for treatment - Control tests for softening - Treated water - Tests for carbonate and phosphate conditioning - Dissolved oxygen - Blow-down testing - Embrittlement ratios - General water analysis - Analysis of scales- Residual chlorine - Tannins - Appendix - Index - Standard solutions - Reagents-Clark's table of hardnesses - Chemical factors - Conversion tables - Summary of recommended practice -
Boiler Water Treatment: Principles and Practice
Author: Colin Frayne
Publisher:
ISBN: 9780820603711
Category : Technology & Engineering
Languages : en
Pages : 0
Book Description
BOILER WATER TREATMENT, PRINCIPLES AND PRACTICE VOLUME 1 of Two Volumes by COLIN FRAYNE. Vol. I: Boiler Basics and Steam Water Chemistry, ISBN: 0-8206-0371-6 This comprehensive reference is the most practical field guide ever written on steam and boiler water treatment. In this two-volume handbook, Colin Frayne (Cooling Water Treatment, Principles and Practice, also by Chemical Publishing) analyzes the whole spectrum of boiler systems, including those used in residential complexes, commercial and institutional buildings, and industrial facilities. The breadth of the book covers: All types of boilers plants, from small cast iron units to large utility and nuclear power plants. Boiler subsystems, appurtenances, and auxiliaries Boiler maintenance and troubleshooting, fuel treatments, combustion gas analysis, pre-treatment processes, chemicals, and operational management Historical and modern program design and control in accordance with international standards Introduction; The Function of Boiler Water; Treatment and Its Marketing Steam Generation; Boiler Types and Applications; Boiler Plant Subsystems, Appurtenances, and Auxiliaries; Waterside and Steamside Problems: The Basics; Waterside and Steamside Problems: Hot Water Heating and Low-Pressure Steam Boiler; Waterside and Steamside Problems: Pre-Boiler Section Specifics; Waterside and Steamside Problems: Boiler Section Specifics; Waterside and Steamside Problems: Post-Boiler Section Specifics; Pre-Boiler and Post-Boiler Treatment Processes; Internal Treatment Programs; Adjuncts and Conjuctional Treatments; Control of Boiler Water Chemistry; Operational Control of Waterside Surfaces; Control of Fireside Conditions and Surfaces. Appendix I Useful Data; Appendix II Glossary; Bibliography. Index. This book is Volume 1 of a 2 Volume set. Other titles by author Colin Frayne: Cooling Water Treatment: Principles and Practice ISBN 978-0-8206-0370-4; Cooling Water Treatment Principles and Practices: Charts and Notes For Field Use ISBN 978-0-8206-0003-1
Publisher:
ISBN: 9780820603711
Category : Technology & Engineering
Languages : en
Pages : 0
Book Description
BOILER WATER TREATMENT, PRINCIPLES AND PRACTICE VOLUME 1 of Two Volumes by COLIN FRAYNE. Vol. I: Boiler Basics and Steam Water Chemistry, ISBN: 0-8206-0371-6 This comprehensive reference is the most practical field guide ever written on steam and boiler water treatment. In this two-volume handbook, Colin Frayne (Cooling Water Treatment, Principles and Practice, also by Chemical Publishing) analyzes the whole spectrum of boiler systems, including those used in residential complexes, commercial and institutional buildings, and industrial facilities. The breadth of the book covers: All types of boilers plants, from small cast iron units to large utility and nuclear power plants. Boiler subsystems, appurtenances, and auxiliaries Boiler maintenance and troubleshooting, fuel treatments, combustion gas analysis, pre-treatment processes, chemicals, and operational management Historical and modern program design and control in accordance with international standards Introduction; The Function of Boiler Water; Treatment and Its Marketing Steam Generation; Boiler Types and Applications; Boiler Plant Subsystems, Appurtenances, and Auxiliaries; Waterside and Steamside Problems: The Basics; Waterside and Steamside Problems: Hot Water Heating and Low-Pressure Steam Boiler; Waterside and Steamside Problems: Pre-Boiler Section Specifics; Waterside and Steamside Problems: Boiler Section Specifics; Waterside and Steamside Problems: Post-Boiler Section Specifics; Pre-Boiler and Post-Boiler Treatment Processes; Internal Treatment Programs; Adjuncts and Conjuctional Treatments; Control of Boiler Water Chemistry; Operational Control of Waterside Surfaces; Control of Fireside Conditions and Surfaces. Appendix I Useful Data; Appendix II Glossary; Bibliography. Index. This book is Volume 1 of a 2 Volume set. Other titles by author Colin Frayne: Cooling Water Treatment: Principles and Practice ISBN 978-0-8206-0370-4; Cooling Water Treatment Principles and Practices: Charts and Notes For Field Use ISBN 978-0-8206-0003-1
Boiler Water Treatment Principles and Practice
Author: Colin Frayne
Publisher: Chemical Publishing Company
ISBN: 9780820601731
Category : Technology & Engineering
Languages : en
Pages : 66
Book Description
Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - [ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - [ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - [ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - [ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - [ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - [ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes
Publisher: Chemical Publishing Company
ISBN: 9780820601731
Category : Technology & Engineering
Languages : en
Pages : 66
Book Description
Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - [ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - [ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - [ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - [ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - [ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - [ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes
Boiler Feed Water Treatment
Author: F. J. Matthews
Publisher:
ISBN:
Category : Feed-water purification
Languages : en
Pages : 236
Book Description
Publisher:
ISBN:
Category : Feed-water purification
Languages : en
Pages : 236
Book Description
Betz Handbook of Industrial Water Conditioning
Author: Betz Laboratories
Publisher:
ISBN: 9781258800574
Category :
Languages : en
Pages : 424
Book Description
Publisher:
ISBN: 9781258800574
Category :
Languages : en
Pages : 424
Book Description