This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained from piping, equipment, or facilities connected to tank 241-ER-311. The purpose of this sampling event is to obtain information about the effects of the argon purge gas added to tank 241-ER-311. Vapor samples will be taken in the encasement of transfer lines, at the ER-151 diversion box, and, as necessary, any other locations connected to tank 241-ER-311. Combustible gas, ammonia, and organic vapor levels will be field-measured using hand-held instruments. Vapor samples will be taken and shipped to the Pacific Northwest National Laboratory (PNNL) for analysis. This test plan identifies the sample collection, laboratory analysis, quality assurance, and reporting objectives for this data collection effort. The plan also provides the requirements for vapor measurements performed in the field.

Tank 241ER311 Interconnected Piping and Equipment Vapor Sampling and Analysis Plan

Tank 241ER311 Interconnected Piping and Equipment Vapor Sampling and Analysis Plan PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Get Book Here

Book Description
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained from piping, equipment, or facilities connected to tank 241-ER-311. The purpose of this sampling event is to obtain information about the effects of the argon purge gas added to tank 241-ER-311. Vapor samples will be taken in the encasement of transfer lines, at the ER-151 diversion box, and, as necessary, any other locations connected to tank 241-ER-311. Combustible gas, ammonia, and organic vapor levels will be field-measured using hand-held instruments. Vapor samples will be taken and shipped to the Pacific Northwest National Laboratory (PNNL) for analysis. This test plan identifies the sample collection, laboratory analysis, quality assurance, and reporting objectives for this data collection effort. The plan also provides the requirements for vapor measurements performed in the field.

Sampling and Analysis Plan for Catch Tank 241ER311 Vapor

Sampling and Analysis Plan for Catch Tank 241ER311 Vapor PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 15

Get Book Here

Book Description
This tank sampling and analysis plan (TSAF') identifies the sample collection, laboratory analysis, quality assurance/quality control (QA/QC) objectives for the characterization of catch tank 241-ER-311 vapor space. Data to be collected under this revision (Revision 2) of the TSAP will be used to evaluate the effectiveness of the portable exhauster recently installed for the tank. Vapor samples taken previous to the issuance of this revision shall be analyzed in accordance with Revision 1.

Tank 241-AP-102 Vapor Sampling and Analysis Plan

Tank 241-AP-102 Vapor Sampling and Analysis Plan PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 61

Get Book Here

Book Description
This tank sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples from the head space of tank 241-AP-102. Sampling will be performed in accordance with ''Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis'' (Air DQO) (Mulkey 1999). The sample results will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications. Samples taken in support of the DQO will consist of SUMMA{trademark} canisters, triple sorbent traps (TSTs), sorbent tube trains (STTs), polyurethane foam (PUF) samples, and particulate filters. Particulate filter samples and tritium traps will be taken for radiation screening to allow the release of the samples for analysis and for analysis of specific radionuclides. The following sections provide the general methodology and procedures to be used in the preparation, retrieval, transport, analysis, and reporting of results from the vapor samples.

Vapor Sampling and Analysis Plan. Revision 1

Vapor Sampling and Analysis Plan. Revision 1 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 28

Get Book Here

Book Description
This document is a plan which serves as the contractual agreement between the Characterization Program, Sampling Operations, Oak Ridge National Laboratory, and PNL tank vapor program. The scope of this plan is to provide guidance for the sampling and analysis of vapor samples from both SST and DST tanks.

Tank 241-Z-361 Vapor Sampling and Analysis Plan

Tank 241-Z-361 Vapor Sampling and Analysis Plan PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 178

Get Book Here

Book Description
Tank 241-Z-361 is identified in the Hanford Federal Facility Agreement and Consent Order (commonly referred to as the Tri-Party Agreement), Appendix C, (Ecology et al. 1994) as a unit to be remediated under the authority of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). As such, the U.S. Environmental Protection Agency will serve as the lead regulatory agency for remediation of this tank under the CERCLA process. At the time this unit was identified as a CERCLA site under the Tri-Party Agreement, it was placed within the 200-ZP-2 Operable Unit. In 1997, The Tri-parties redefined 200 Area Operable Units into waste groupings (Waste Site Grouping for 200 Areas Soils Investigations [DOE-RL 1992 and 1997]). A waste group contains waste sites that share similarities in geological conditions, function, and types of waste received. Tank 241-Z-361 is identified within the CERCLA Plutonium/Organic-rich Process Condensate/Process Waste Group (DOE-RL 1992). The Plutonium/Organic-rich Process Condensate/Process Waste Group has been prioritized for remediation beginning in the year 2004. Results of Tank 216-Z-361 sampling and analysis described in this Sampling and Analysis Plan (SAP) and in the SAP for sludge sampling (to be developed) will determine whether expedited response actions are required before 2004 because of the hazards associated with tank contents. Should data conclude that remediation of this tank should occur earlier than is planned for the other sites in the waste group, it is likely that removal alternatives will be analyzed in a separate Engineering Evaluation/Cost Analysis (EE/CA). Removal actions would proceed after the U.S. Environmental Protection Agency (EPA) signs an Action Memorandum describing the selected removal alternative for Tank 216-Z-361. If the data conclude that there is no immediate threat to human health and the environment from this tank, remedial actions for the tank will be defined in a feasibility study for the entire waste group.

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 36

Get Book Here

Book Description
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.

Tank 241-BY-112 Vapor Sampling and Analysis Tank Characterization Report

Tank 241-BY-112 Vapor Sampling and Analysis Tank Characterization Report PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 20

Get Book Here

Book Description
Tank 241-BY-112 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. The drivers and objectives of waste tank headspace sampling and analysis are discussed in {open_quotes}Program Plan for the Resolution of Tank Vapor Issues.{close_quotes} Tank 241-BY-112 was vapor sampled in accordance with {open_quotes}Data Quality Objectives for Generic In-Tank Health and Safety Issue Resolution.{close_quotes}