Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation PDF Author: E. B. McFadden
Publisher:
ISBN:
Category : Aerospace medicine
Languages : en
Pages : 24

Get Book Here

Book Description
The report describes evaluation of two prototype phase dilution rebreathing masks as compared to an open port rebreathing mask design. Human subjects wearing the prototype masks and engaged in three minute periods of rest and exercise were exposed to altitudes of 14,000, 18,000, 25,000, 30,000 and 34,000 feet in an altitude chamber. Each subject was instrumented to obtain a variety of physiological parameters including end expiratory gas composition, blood oxygen saturation (ear oximetry), ECG, and respiratory rate (impedance pneumograph). Oxygen flow and system pressure as provided by an automatic constant-flow regulator were also determined. The automatic constant-flow regulator when used in conjunction with either of the prototype phase dilution rebreather test masks and proper orifices maintained the subjects' indicated blood oxygen saturations equal to or in excess of their ground level (1,273 feet) baselines. With the same oxygen flow rates the prototype porous and dilution valve masks provided higher tracheal oxygen partial pressures than the open port masks at all altitudes tested during rest and exercise. The prototype phase dilution rebreather masks appear to be more efficient since at the same flow rates a greater amount of oxygen was derived from the supply and less oxygen lost to the ambient environment as compared to the open port type mask. (Author).

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation PDF Author: E. B. McFadden
Publisher:
ISBN:
Category : Aerospace medicine
Languages : en
Pages : 24

Get Book Here

Book Description
The report describes evaluation of two prototype phase dilution rebreathing masks as compared to an open port rebreathing mask design. Human subjects wearing the prototype masks and engaged in three minute periods of rest and exercise were exposed to altitudes of 14,000, 18,000, 25,000, 30,000 and 34,000 feet in an altitude chamber. Each subject was instrumented to obtain a variety of physiological parameters including end expiratory gas composition, blood oxygen saturation (ear oximetry), ECG, and respiratory rate (impedance pneumograph). Oxygen flow and system pressure as provided by an automatic constant-flow regulator were also determined. The automatic constant-flow regulator when used in conjunction with either of the prototype phase dilution rebreather test masks and proper orifices maintained the subjects' indicated blood oxygen saturations equal to or in excess of their ground level (1,273 feet) baselines. With the same oxygen flow rates the prototype porous and dilution valve masks provided higher tracheal oxygen partial pressures than the open port masks at all altitudes tested during rest and exercise. The prototype phase dilution rebreather masks appear to be more efficient since at the same flow rates a greater amount of oxygen was derived from the supply and less oxygen lost to the ambient environment as compared to the open port type mask. (Author).

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation [with List of References

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation [with List of References PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 12

Get Book Here

Book Description


Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation

Performance Characteristics of Constant-flow Phase Dilution Oxygen Mask Designs for General Aviation PDF Author: Earnest B. McFadden
Publisher:
ISBN:
Category :
Languages : en
Pages : 18

Get Book Here

Book Description
The report describes evaluation of two prototype phase dilution rebreathing masks as compared to an open port rebreathing mask design. Human subjects wearing the prototype masks and engaged in three minute periods of rest and exercise were exposed to altitudes of 14,000, 18,000, 25,000, 30,000 and 34,000 feet in an altitude chamber. Each subject was instrumented to obtain a variety of physiological parameters including end expiratory gas composition, blood oxygen saturation (ear oximetry), ECG, and respiratory rate (impedance pneumograph). Oxygen flow and system pressure as provided by an automatic constant-flow regulator were also determined. The automatic constant-flow regulator when used in conjunction with either of the prototype phase dilution rebreather test masks and proper orifices maintained the subjects' indicated blood oxygen saturations equal to or in excess of their ground level (1,273 feet) baselines. With the same oxygen flow rates the prototype porous and dilution valve masks provided higher tracheal oxygen partial pressures than the open port masks at all altitudes tested during rest and exercise. The prototype phase dilution rebreather masks appear to be more efficient since at the same flow rates a greater amount of oxygen was derived from the supply and less oxygen lost to the ambient environment as compared to the open port type mask. (Author).

Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 1460

Get Book Here

Book Description
Lists citations with abstracts for aerospace related reports obtained from world wide sources and announces documents that have recently been entered into the NASA Scientific and Technical Information Database.

Government-wide Index to Federal Research & Development Reports

Government-wide Index to Federal Research & Development Reports PDF Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1020

Get Book Here

Book Description


Technical Abstract Bulletin

Technical Abstract Bulletin PDF Author: Defense Documentation Center (U.S.)
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 784

Get Book Here

Book Description


Aviation Medical Reports

Aviation Medical Reports PDF Author: United States. Office of Aviation Medicine
Publisher:
ISBN:
Category : Aviation medicine
Languages : en
Pages : 506

Get Book Here

Book Description


Soaring

Soaring PDF Author:
Publisher:
ISBN:
Category : Gliders
Languages : en
Pages : 652

Get Book Here

Book Description


Index to FAA Office of Aviation Medicine Reports

Index to FAA Office of Aviation Medicine Reports PDF Author: United States. Office of Aviation Medicine
Publisher:
ISBN:
Category : Aviation medicine
Languages : en
Pages : 32

Get Book Here

Book Description


Index to FAA Office of Aviation Medicine Reports: 1961 Through 1971

Index to FAA Office of Aviation Medicine Reports: 1961 Through 1971 PDF Author: United States. Office of Aviation Medicine
Publisher:
ISBN:
Category : Aviation medicine
Languages : en
Pages : 38

Get Book Here

Book Description
An index to Office of Aviation Medicine Reports (1964 - 1971) and Civil Aeromedical Research Institute Reports (1961 - 1963) is presented as a quick reference for those engaged in aviation medicine and related activities. It provides a listing of all FAA aviation medicine reports published from 1961 through 1971 by year, number, author, subject and title. (Author).