DIFFUSION ET ELECTROMIGRATION DANS DES OXYDES CUBIQUES A HAUTE TEMPERATURE. APPLICATION AUX OXYDES DE COBALT CO#1##O ET DE MANGANESE MN#1##O

DIFFUSION ET ELECTROMIGRATION DANS DES OXYDES CUBIQUES A HAUTE TEMPERATURE. APPLICATION AUX OXYDES DE COBALT CO#1##O ET DE MANGANESE MN#1##O PDF Author: THANH.. TADUY
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
CETTE THESE CONCERNE LA MESURE DU COEFFICIENT DE DIFFUSION CHIMIQUE DE COO ET MNO A 1108C POUR DIFFERENTES PRESSIONS PARTIELLES D'OXYGENE D'EQUILIBRE. LES METHODES EXPERIMENTALES MISES EN UVRE UTILISENT DE L'ELECTROCHIMIE DU SOLIDE ET CECI AFIN DE PERMETTRE DES MESURES DE RELAXATION D'UN GRADIENT DE CONCENTRATION DANS LE MATERIAU SANS QUE SOIT MIS EN JEU, AU COURS DE CE PROCESSUS, UN QUELCONQUE TRANSFERT DE MATIERE AUX INTERFACES DU MATERIAU. CE TYPE DE MESURE PERMET D'ELIMINER A PRIORI DES SOURCES D'ERREUR DANS LA MESURE DE D RELIEES A LA RESISTANCE DE TRANSFERT DE MATIERE AUX INTERFACES. LES RESULTATS OBTENUS INDIQUENT QUE D NE DEPEND QUE PEU OU PAS DE LA PRESSION PARTIELLE D'OXYGENE A 1108C, (D#C#O#O=1,610##6 CM#2S# D#M#N#O=610##7 CM#2S##1) DANS LE CAS DE L'OXYDE COBALT, CES MESURES ONT PERMIS DE DEDUIRE UNE VALEUR DU RAPPORT DE HAVEN COMPATIBLE AVEC UN MECANISME DE DIFFUSION PAR LACUNES DE COBALT

DIFFUSION ET ELECTROMIGRATION DANS DES OXYDES CUBIQUES A HAUTE TEMPERATURE. APPLICATION AUX OXYDES DE COBALT CO#1##O ET DE MANGANESE MN#1##O

DIFFUSION ET ELECTROMIGRATION DANS DES OXYDES CUBIQUES A HAUTE TEMPERATURE. APPLICATION AUX OXYDES DE COBALT CO#1##O ET DE MANGANESE MN#1##O PDF Author: THANH.. TADUY
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
CETTE THESE CONCERNE LA MESURE DU COEFFICIENT DE DIFFUSION CHIMIQUE DE COO ET MNO A 1108C POUR DIFFERENTES PRESSIONS PARTIELLES D'OXYGENE D'EQUILIBRE. LES METHODES EXPERIMENTALES MISES EN UVRE UTILISENT DE L'ELECTROCHIMIE DU SOLIDE ET CECI AFIN DE PERMETTRE DES MESURES DE RELAXATION D'UN GRADIENT DE CONCENTRATION DANS LE MATERIAU SANS QUE SOIT MIS EN JEU, AU COURS DE CE PROCESSUS, UN QUELCONQUE TRANSFERT DE MATIERE AUX INTERFACES DU MATERIAU. CE TYPE DE MESURE PERMET D'ELIMINER A PRIORI DES SOURCES D'ERREUR DANS LA MESURE DE D RELIEES A LA RESISTANCE DE TRANSFERT DE MATIERE AUX INTERFACES. LES RESULTATS OBTENUS INDIQUENT QUE D NE DEPEND QUE PEU OU PAS DE LA PRESSION PARTIELLE D'OXYGENE A 1108C, (D#C#O#O=1,610##6 CM#2S# D#M#N#O=610##7 CM#2S##1) DANS LE CAS DE L'OXYDE COBALT, CES MESURES ONT PERMIS DE DEDUIRE UNE VALEUR DU RAPPORT DE HAVEN COMPATIBLE AVEC UN MECANISME DE DIFFUSION PAR LACUNES DE COBALT