Development of a Database for Prompt Gamma-ray Neutron Activation Analysis

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis PDF Author: Richard M. Lindstrom
Publisher:
ISBN:
Category : Gamma ray spectrometry
Languages : en
Pages : 91

Get Book Here

Book Description

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis PDF Author: Richard M. Lindstrom
Publisher:
ISBN:
Category : Gamma ray spectrometry
Languages : en
Pages : 91

Get Book Here

Book Description


Development of a database for prompt gamma-ray neutron activation analysis

Development of a database for prompt gamma-ray neutron activation analysis PDF Author: Richard B. Firestone
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The main discussions and conclusions from the Third Co-ordination Meeting on the Development of a Database for Prompt Gamma-ray Neutron Activation Analysis are summarized in this report. All results were reviewed in detail, and the final version of the TECDOC and the corresponding software were agreed upon and approved for preparation. Actions were formulated with the aim of completing the final version of the TECDOC and associated software by May 2003.

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The main discussions and conclusions from the Third Co-ordination Meeting on the Development of a Database for Prompt Gamma-ray Neutron Activation Analysis are summarized in this report. All results were reviewed in detail, and the final version of the TECDOC and the corresponding software were agreed upon and approved for preparation. Actions were formulated with the aim of completing the final version of the TECDOC and associated software by May 2003.

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis

Development of a Database for Prompt Gamma-ray Neutron Activation Analysis PDF Author: R. Paviotti-Corcuera
Publisher:
ISBN:
Category : Gamma ray spectrometry
Languages : en
Pages : 76

Get Book Here

Book Description


Database of Prompt Gamma Rays from Slow Neutron Capture Forelemental Analysis

Database of Prompt Gamma Rays from Slow Neutron Capture Forelemental Analysis PDF Author: H. D. Choi
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The increasing importance of Prompt Gamma-ray ActivationAnalysis (PGAA) in a broad range of applications is evident, and has beenemphasized at many meetings related to this topic (e.g., TechnicalConsultants' Meeting, Use of neutron beams for low- andmedium-fluxresearch reactors: radiography and materialscharacterizations, IAEA Vienna, 4-7 May 1993, IAEA-TECDOC-837, 1993). Furthermore, an Advisory Group Meeting (AGM) for the Coordination of theNuclear Structure and Decay Data Evaluators Network has stated that thereis a need for a complete and consistent library of cold- and thermalneutron capture gammaray and cross-section data (AGM held at Budapest,14-18 October 1996, INDC(NDS)-363); this AGM also recommended theorganization of an IAEA CRP on the subject. The International NuclearData Committee (INDC) is the primary advisory body to the IAEA NuclearData Section on their nuclear data programmes. At a biennial meeting in1997, the INDC strongly recommended that the Nuclear Data Section supportnew measurements andupdate the database on Neutron-induced PromptGamma-ray Activation Analysis (21st INDC meeting, INDC/P(97)-20). As aconsequence of the various recommendations, a CRP on "Development of aDatabase for Prompt Gamma-ray Neutron Activation Analysis (PGAA)" wasinitiated in 1999. Prior to this project, several consultants had definedthe scope, objectives and tasks, as approved subsequently by the IAEA. Each CRP participant assumed responsibility for the execution of specifictasks. The results of their and other research work were discussed andapproved by the participants in research co-ordination meetings (seeSummary reports: INDC(NDS)-411, 2000; INDC(NDS)-424, 2001; andINDC(NDS)-443, 200). PGAA is a non-destructive radioanalytical method, capable of rapid or simultaneous "in-situ" multi-element analyses acrossthe entire Periodic Table, from hydrogen to uranium. However, inaccurateand incomplete data were a significant hindrance in the qualitative andquantitative analysis of complicated capture-gamma spectra by means ofPGAA. Therefore, the main goal of the CRP was to improve the quality andquantity of the required data in order to make possible the reliableapplication of PGAA in fields such as materials science, chemistry, geology, mining, archaeology, environment, food analysis and medicine. This aim wasachieved thanks to the dedicated work and effort of theparticipants. The CD-ROM included with this publication contains thedatabase, the retrieval system, the three CRM reports, and otherimportant electronic documents related to the CRP. The IAEA wishes tothanks all CRP participants who contributed to the success of the CRP and the formulation of this publication. Special thanks are due to R.B. Firestone for his leading roll in the development of this CRP and hiscomprehensive compilation, analysis and provision of the adopteddatabase, and to V. Zerkin for the software developments associatedwiththe retrieval system. An essential component of this data compilation isthe extensive sets of new measurements of capture gamma-ray energies andintensities undertaken at Budapest by Zs. Revay under the direction ofG. L. Molnar. The extensive participation and assistance of H.D. Choi isalso greatly appreciated. Other participants inthis CRP were: R.M. Lindstrom, S.M. Mughabghab, A.V.R. Reddy, V.H. Tan and C.M. Zhou. Thanksare also due to S.C. Frankle and M.A. Lone for their active participationas consultants at some of the meetings. Finally, the participants wish tothank R. Paviotti-Corcuera (Nuclear Data Section, Division of Physicaland Chemical Sciences), who was the IAEA responsible officer for the CRP, this publication and the resulting database. The participants aregrateful to D.L. Muir and A.L. Nichols, successive Heads of the NuclearData Section, for their active and enthusiastic encouragement infurthering the work of the CRP.

Database of Prompt Gamma Rays from Slow Neutron Capture for Elemental Analysis

Database of Prompt Gamma Rays from Slow Neutron Capture for Elemental Analysis PDF Author: International Atomic Energy Agency
Publisher: IAEA
ISBN:
Category : Science
Languages : en
Pages : 282

Get Book Here

Book Description
Neutron-capture prompt-gamma activation analysis (PGAA) is particularly valuable as a non-destructive nuclear method in the measurement of elements that do not form neutron capture products with delayed gamma ray emissions. Inaccurate and incomplete data have been a significant hindrance in the qualitative and quantitative analysis of complicated capture gamma spectra by means of PGAA. This database was produced to improve the quality and quantity of required data in order to make possible the reliable application of PGAA in fields such as materials science, geology, mining, archaeology, environment, food analysis and medicine. The database provides a variety of tables for all natural elements (from H to U) including the following data: isotopic composition, thermal radiative cross-section (total and partial), Westcott g-factors, energy of the gamma rays (prompt and delayed), decay mode, half-life and branching ratios. The CD-ROM included in this publication contains the database, the retrieval system and important electronic documents related to the project.--Publisher's description.

Handbook of Prompt Gamma Activation Analysis

Handbook of Prompt Gamma Activation Analysis PDF Author: G. Molnar
Publisher: Springer Science & Business Media
ISBN: 0387233598
Category : Science
Languages : en
Pages : 448

Get Book Here

Book Description
Prompt gamma activation analysis (PGAA) is a unique, non-destructive nuclear analytical method with multi-element capabilities. It is most effective if intense neutron beams (especially cold beams) of nuclear reactors are used to induce the prompt gamma radiation. Based largely on the authors' pioneering research in cold neutron PGAA, the handbook describes the methodology in self-contained manner and reviews recent applications. The library of prompt gamma ray data and spectra for all natural elements is a unique aid to the practitioner. The level is understandable by a broad audience, which facilitates teaching and training. The Handbook of Prompt Gamma Activation Analysis is a comprehensive handbook written for those practising the method, wanting to implement it at a reactor facility, or just looking for a powerful non-destructive method of element analysis. The book is also useful for nuclear physics, chemistry and engineering scientists, scholars and graduate students interested in neutron-induced gamma ray spectroscopy and nuclear analytical methods.

Development of a Prompt-gamma, Neutron-activation Analysis Facility at the Texas A & M University Nuclear Science Center

Development of a Prompt-gamma, Neutron-activation Analysis Facility at the Texas A & M University Nuclear Science Center PDF Author: Otu Effiong Inyang
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
A prompt-gamma, neutron-activation analysis facility earlier developed at the Nuclear Science Center of Texas A & M University could not be used successfully to analyze geologic samples due to high detection background, low neutron fluence rate and poor detection equipment . A systematic investigation into the performance capability of a prompt-gamma, neutron activation analysis facility was undertaken in this research project. The facility was reconstructed and used to obtain prompt-gamma spectra of chlorine and cadmium and from the spectra, the net peak area counts for the most intense prompt-gamma-ray energies were obtained. A theoretical model was developed which can predict the net peak area counts expected on these prompt-gamma-ray energies using the thermal neutron fluence rate at the sample position, the absolute efficiency of the detector, and the mass and partial gamma-ray production cross section data for the samples. The experimental and predicted results were compared to establish the performance capability of the reconstructed facility. Good agreements between experimental and predicted results were obtained for chlorine, but results from cadmium showed larger discrepancies due to self-shielding effects. Corrections for self-shielding effects were applied to results from cadmium and the experimental and predicted results were also in good agreement. The satisfactory results indicate that it is possible to implement the prompt-gamma, neutron-activation analysis technique at Beam Port #1 of the Nuclear Science Center Reactor. To be able to obtain excellent results from other samples, improvements in shielding materials to attain a lower detection background and a highly efficient detection system should be incorporated.

Development of a Prompt Gamma Neutron Activation Analysis Facility at the University of Missouri Research Reactor and Obsidian Identification

Development of a Prompt Gamma Neutron Activation Analysis Facility at the University of Missouri Research Reactor and Obsidian Identification PDF Author: Abdul-Salam Gubreal Hanna
Publisher:
ISBN:
Category :
Languages : en
Pages : 342

Get Book Here

Book Description


Development of Monte Carlo Code for Coincidence Prompt Gamma-ray Neutron Activation Analysis

Development of Monte Carlo Code for Coincidence Prompt Gamma-ray Neutron Activation Analysis PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Prompt Gamma-Ray Neutron Activation Analysis (PGNAA) offers a non-destructive, relatively rapid on-line method for determination of elemental composition of bulk and other samples. However, PGNAA has an inherently large background. These backgrounds are primarily due to the presence of the neutron excitation source. It also includes neutron activation of the detector and the prompt gamma rays from the structure materials of PGNAA devices. These large backgrounds limit the sensitivity and accuracy of PGNAA. Since Most of the prompt gamma rays from the same element are emitted in coincidence, a possible approach for further improvement is to change the traditional PGNAA detection technique and introduce the gamma-gamma coincidence technique. It is well known that the coincidence technique can eliminate most of the interference backgrounds and improve the signal-to-noise ratio. A new Monte Carlo code CEARCPG is being developed at CEAR to predict coincidence counting in coincidence PGNAA. Compared to the other existing Monte Carlo code, a new algorithm of sampling the prompt gamma rays, which are produced from neutron capture reaction and neutron inelastic scattering reaction, is developed in this work. All the prompt gamma rays are taken into account by using this new algorithm. Before this work, the commonly used method is to interpolate the prompt gamma rays from the pre-calculated gamma-ray table. It works fine for the single spectrum. However it limits the capability to simulate the coincidence spectrum. This new algorithm is to sample the prompt gamma rays from the nucleus scheme. It makes possible to simulate the coincidence spectrum by using Monte Carlo method. The primary nuclear data library used to sample the prompt gamma rays comes from ENSDF library. Three cases are simulated and the simulated results are checked with the experiments. The first case is the prototype for ETI PGNAA application. This case is designed to check the capability of CEARCPG for sing.