Comparison Between Conventional and Injection Moulded Techniques of Processing Acrylic Resin Dentures in Respect to Dimensional Changes

Comparison Between Conventional and Injection Moulded Techniques of Processing Acrylic Resin Dentures in Respect to Dimensional Changes PDF Author: Ayoub Zabida
Publisher:
ISBN:
Category :
Languages : en
Pages : 103

Get Book Here

Book Description


A Comparison of Dimensional Changes of Injection and Conventional Processing of Two Rubber-reinforced Denture Base Acrylic Resins

A Comparison of Dimensional Changes of Injection and Conventional Processing of Two Rubber-reinforced Denture Base Acrylic Resins PDF Author: Daniel Leagh Cruz
Publisher:
ISBN:
Category :
Languages : en
Pages : 108

Get Book Here

Book Description


Comparative Study of Dimensional Accuracy of Three Denture Base Resin

Comparative Study of Dimensional Accuracy of Three Denture Base Resin PDF Author: Naveen Yadav
Publisher: LAP Lambert Academic Publishing
ISBN: 9783659160004
Category :
Languages : en
Pages : 92

Get Book Here

Book Description
Poor adaptations of acrylic resin denture bases to the supporting tissues markedly decrease denture retention. Several denture base resin and processing techniques have been introduced to the profession, each claiming to produce a more accurate base. Microwave processing techniques has been introduced claims to minimize the dimensional changes.This purpose of this study was to compare the dimensional accuracy of three denture base resins when processed both by conventional water bath method and by use of microwave energy. Three Poly (MethylMethacrylate) heat cure resins selected for this study. These resins were processed by conventional water bath technique for 1 1/2 hours at 75 degree & half hour at 100 degree and by microwave energy for 3 mins at 500W. The measurements of acrylic resin denture base specimens were compared with the measurements of master metal die dimension keeping it as a standard measurement. The mean values of the difference in the points compared were calculated, & compared to each other to determine if there was a statistically significant difference between them at the 0.05 probability level using the students' independent test for pooled variances

The Effect of Processing Techniques on the Dimensional Accuracy of Acrylic Resin Dentures

The Effect of Processing Techniques on the Dimensional Accuracy of Acrylic Resin Dentures PDF Author: Mark Francis LoSchiavo
Publisher:
ISBN:
Category : Dental resins
Languages : en
Pages : 230

Get Book Here

Book Description


Journal of Prosthodontics on Complete and Removable Dentures

Journal of Prosthodontics on Complete and Removable Dentures PDF Author: Jonathan P. Wiens
Publisher: John Wiley & Sons
ISBN: 1119442621
Category : Medical
Languages : en
Pages : 290

Get Book Here

Book Description
This book is a compilation of articles on complete dentures selected from the Journal of Prosthodontics with the intention of providing the reader with contemporary and relevant information on how the edentulous patient can be better served when fabricating complete dentures. Presents a curated list of the best peer-reviewed articles on complete and removable dentures from the pages of Journal of Prosthodontics Covers a wide range of treatment scenarios involving fixed and partial dentures Offers a mix of clinical reports, research articles, and reviews

Effect of Cooling Procedures Over Linear Dimensional Changes in PMMA

Effect of Cooling Procedures Over Linear Dimensional Changes in PMMA PDF Author: Aqeel Ibrahim
Publisher: LAP Lambert Academic Publishing
ISBN: 9783659436154
Category :
Languages : en
Pages : 72

Get Book Here

Book Description
Denture bases are commonly made from acrylic resins, which were introduced by Dr. Walter Wright back in 1937. Among these, polymethyl methacrylate (PMMA) is the most commonly used. PMMA material is mostly processed by wet heat and compression molding techniques, which deliver dentures with acceptable mechanical properties. However, certain dimensional changes are known to occur in acrylic resin during or after its processing. These changes hold clinical significance because for better adaptation to oral tissues, denture base material must have dimensional accuracy during and after its processing. However, inaccuracies tend to occur due to unavoidable changes during fabrication such as thermal expansion on heating, contraction on cooling and polymerization shrinkage. The purported significance of this study is to find out the most suitable cooling procedure for achieving maximum dimensional accuracy following a standard heating cycle. This will lead to the fabrication of a denture which will have better retention, support, stability.

Comparison of the Dimensional Accuracy of Injection Molded Denture Base Materials to that of Conventional Pressure-pack Acrylic Resin

Comparison of the Dimensional Accuracy of Injection Molded Denture Base Materials to that of Conventional Pressure-pack Acrylic Resin PDF Author: Ali Parvizi
Publisher:
ISBN:
Category :
Languages : en
Pages : 256

Get Book Here

Book Description


Dental Laboratory Procedures

Dental Laboratory Procedures PDF Author: Sanjna Nayar
Publisher: Elsevier Health Sciences
ISBN: 8131256103
Category :
Languages : en
Pages : 1337

Get Book Here

Book Description
-Detailed dental implant laboratory procedures for multiple clinical conditions with recent advances -Extensive chapter on virtual laboratory -Laboratory disinfection protocol for COVID-19 -Detailed discussion of metal ceramics and all ceramics -More than 3400 coloured photos and illustrations -More than 100 flowcharts and diagrams for easy understanding -Mouthguards and TMJ appliances -Digital version and videos for enhanced learning -Comprehensive laboratory reference for prosthodontists and clinicians

Implant Laboratory Procedures

Implant Laboratory Procedures PDF Author: Carl Drago
Publisher: John Wiley & Sons
ISBN: 0813821029
Category : Medical
Languages : en
Pages : 347

Get Book Here

Book Description
Implant Laboratory Procedures: A Step-By-Step Guide provides its readers with a systematic and practical approach to the common dental laboratory procedures associated with implant restorative dentistry. Written with laboratory technicians and restorative dentists in mind, the book is organized by case type, taking common case scenarios and devoting a separate chapter to each one in turn, demonstrating each step of the laboratory procedure required for the implant restoration. Complications associated with the various prosthetic procedures are also included in each chapter and work orders are shown for each and every step. Cases are illustrated with products from various implant companies, but predominantly feature products from Biomet 3i.

A Comparison of Palatal Adaptation in Acrylic Resin Denture Bases Using Conventional and Anchored Processing Techniques

A Comparison of Palatal Adaptation in Acrylic Resin Denture Bases Using Conventional and Anchored Processing Techniques PDF Author: Gayle A. Laughlin
Publisher:
ISBN:
Category :
Languages : en
Pages : 152

Get Book Here

Book Description
The accuracy of a complete denture base to its supporting tissues is of paramount importance to the fit, function, and health of the oral tissues. Polymerization shrinkage is an inherent characteristic of acrylic resin which can introduce discrepancies in the adaptation of the denture base, especially in the posterior palatal area. The purpose of this investigation was to determine if there was a statistically significant difference in the palatal adaptation of denture bases to their casts as a consequence of palatal shape, presence of mechanical anchoring, or the interaction of these two variables as measured at the vestibule, ridge, lateral palate and mid palate. Forty-eight denture bases were processed using the compression molding technique with Lucitone 199. The master casts vaied by steep or shallow palatal form and the presence or absence of mechanical anchoring holes placed in the land area adjacent to the posterior border of the base. The bases on their casts were sectioned at the posterior border area after processing and evaluated for exactness of adaptation. The gap at the interface of the base and the cast was measured at specific mediolateral locations. Analysis of the interface gap data was done by a three-way ANOVA. A statistically significant decrease of gap distance and improvement of adaptation for both shallow and steep denture bases were observed with the anchoring technique. There was ano statistically significant difference in the magnitude of the interface gap between the steep and shallow palate forms. However, the shallow forms had a wider gap area reaching from ridge to ridge, whereas the steep forms had a gap area confined mainly to the midline. The clinical success and retention of a maxiliary denture is directly related to the intimate fit of the base in the posterior palatal region. The simple procedure of placing anchorage in the master cast before processing has been shown to improve the adaptation and fit of the base in the critical posterior palatal area.