Addendum to the ATC-20 Postearthquake Building Safety Evaluation Procedures

Addendum to the ATC-20 Postearthquake Building Safety Evaluation Procedures PDF Author:
Publisher:
ISBN:
Category : Building inspection
Languages : en
Pages : 110

Get Book Here

Book Description

Addendum to the ATC-20 Postearthquake Building Safety Evaluation Procedures

Addendum to the ATC-20 Postearthquake Building Safety Evaluation Procedures PDF Author:
Publisher:
ISBN:
Category : Building inspection
Languages : en
Pages : 110

Get Book Here

Book Description


Recommended Postearthquake Evaluation and Repair Criteria for Welded Steel Moment-frame Buildings

Recommended Postearthquake Evaluation and Repair Criteria for Welded Steel Moment-frame Buildings PDF Author: SAC Joint Venture. Guidelines Development Committee
Publisher: FEMA
ISBN:
Category : Building, Iron and steel
Languages : en
Pages : 200

Get Book Here

Book Description


Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings

Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings PDF Author:
Publisher:
ISBN:
Category : Buildings
Languages : en
Pages : 270

Get Book Here

Book Description


Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings

Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings PDF Author: Federal Emergency Agency
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 274

Get Book Here

Book Description
Following the two damaging California earthquakes in 1989 (Loma Prieta) and 1994 (Northridge), many concrete wall and masonry wall buildings were repaired using federal disaster assistance funding. The repairs were based on inconsistent criteria, giving rise to controversy regarding criteria for the repair of cracked concrete and masonry wall buildings. To help resolve this controversy, the Federal Emergency Management Agency (FEMA) initiated a project on evaluation and repair of earthquake damaged concrete and masonry wall buildings in 1996. The ATC-43 project addresses the investigation and evaluation of earthquake damage and discusses policy issues related to the repair and upgrade of earthquake damaged buildings. The project deals with buildings whose primary lateral-force-resisting systems consist of concrete or masonry bearing walls with flexible or rigid diaphragms, or whose vertical-load-bearing systems consist of concrete or steel frames with concrete or masonry infill panels. The intended audience is design engineers, building owners, building regulatory officials, and government agencies. The project results are reported in three documents. The FEMA 306 report, Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, Basic Procedures Manual, provides guidance on evaluating damage and analyzing future performance. Included in the document are component damage classification guides, and test and inspection guides. FEMA 307, Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, Technical Resources, contains supplemental information including results from a theoretical analysis of the effects of prior damage on single-degree-of-freedom mathematical models, additional background information on the component guides, and an example of the application of the basic procedures. FEMA 308, The Repair of Earthquake Damaged Concrete and Masonry Wall Buildings, discusses the policy issues pertaining to the repair of earthquake damaged buildings and illustrates how the procedures developed for the project can be used to provide a technically sound basis for policy decisions. It also provides guidance for the repair of damaged components.

Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings (FEMA 351)

Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings (FEMA 351) PDF Author: Federal Emergency Agency
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 256

Get Book Here

Book Description
This report, FEMA-351 - Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings has been developed by the SAC Joint Venture under contract to the Federal Emergency Management Agency (FEMA) to provide structural engineers with recommended criteria for evaluation of the probable performance of existing steel moment-frame buildings in future earthquakes and to provide a basis for updating and revision of evaluation and rehabilitation guidelines and standards. It is one of a series of companion publications addressing the issue of the seismic performance of steel moment-frame buildings. The set of companion publications includes: FEMA-350 - Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings. This publication provides recommended criteria, supplemental to FEMA-302 - 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, for the design and construction of steel moment-frame buildings and provides alternative performance-based design criteria. FEMA-351 - Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings. This publication provides recommended methods to evaluate the probable performance of existing steel moment-frame buildings in future earthquakes and to retrofit these buildings for improved performance. FEMA-352 - Recommended Postearthquake Evaluation and Repair Criteria for Welded Steel Moment-Frame Buildings. This publication provides recommendations for performing postearthquake inspections to detect damage in steel moment-frame buildings following an earthquake, evaluating the damaged buildings to determine their safety in the postearthquake environment, and repairing damaged buildings. FEMA-353 - Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications. This publication provides recommended specifications for the fabrication and erection of steel moment frames for seismic applications. The recommended design criteria contained in the other companion documents are based on the material and workmanship standards contained in this document, which also includes discussion of the basis for the quality control and quality assurance criteria contained in the recommended specifications. The information contained in these recommended evaluation and upgrade criteria, hereinafter referred to as Recommended Criteria, is presented in the form of specific recommendations for design and performance evaluation procedures together with supporting commentary explaining part of the basis for these recommendations.

Repair of Earthquake Damaged Concrete and Masonry Wall Buildings

Repair of Earthquake Damaged Concrete and Masonry Wall Buildings PDF Author: Federal Emergency Agency
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 72

Get Book Here

Book Description
Following the two damaging California earthquakes in1989 (Loma Prieta) and 1994 (Northridge), many concrete wall and masonry wall buildings were repaired using federal disaster assistance funding. The repairs were based on inconsistent criteria, giving rise to controversy regarding criteria for the repair of cracked concrete and masonry wall buildings. To help resolve this controversy, the Federal Emergency Management Agency (FEMA) initiated a project on evaluation and repair of earthquake-damaged concrete and masonry wall buildings in 1996. The ATC-43 project addresses the investigation and evaluation of earthquake damage and discusses policy issues related to the repair and upgrade of earthquake-damaged buildings. The project deals with buildings whose primary lateral-force-resisting systems consist of concrete or masonry bearing walls with flexible or rigid diaphragms, or whose vertical-load-bearing systems consist of concrete or steel frames with concrete or masonry infill panels. The intended audience is design engineers, building owners, building regulatory officials, and government agencies. The project results are reported in three documents. TheFEMA306report, Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, Basic Procedures Manual, provides guidance on evaluating damage and analyzing future performance. Included in the document are component damage classification guides, and test and inspection guides. FEMA 307, Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, Technical Resources, contains supplemental information including results from a theoretical analysis of the effects of prior damage on single-degree-of-freedom mathematical models, additional background information on the component guides, and an example of the application of the basic procedures. FEMA 308, The Repair of Earthquake Damaged Concrete and Masonry Wall Buildings ,discusses the policy issues pertaining to the repair of earthquake-damaged buildings and illustrates how the procedures developed for the project can be used to provide a technically sound basis for policy decisions. It also provides guidance for the repair of damaged components.

Comprehensive Earthquake Preparedness Planning Guidelines

Comprehensive Earthquake Preparedness Planning Guidelines PDF Author: Southern California Earthquake Preparedness Project
Publisher:
ISBN:
Category : Business insurance
Languages : en
Pages : 276

Get Book Here

Book Description


Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-frame Buildings

Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-frame Buildings PDF Author: SAC Joint Venture. Guidelines Development Committee
Publisher:
ISBN:
Category : Building, Iron and steel
Languages : en
Pages : 260

Get Book Here

Book Description


Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications (FEMA 353)

Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications (FEMA 353) PDF Author: Federal Emergency Agency
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 201

Get Book Here

Book Description
This report, FEMA-353 - Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications has been prepared by the SAC Joint Venture, under contract to the Federal Emergency Management Agency, to indicate those standards of workmanship for structural steel fabrication and erection deemed necessary to achieve reliably the design performance objectives contained in the set of companion publications prepared under this same contract: FEMA-350 - Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, which provides recommended criteria, supplemental to FEMA-302, 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, for the design and construction of steel moment-frame buildings and provides alternative performance-based design criteria; FEMA-351 - Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings, which provides recommended methods to evaluate the probable performance of existing steel moment-frame buildings in future earthquakes and to retrofit these buildings for improved performance; and FEMA-352 - Recommended Postearthquake Evaluation and Repair Criteria for Welded, Steel Moment-Frame Buildings, which provides recommendations for performing postearthquake inspections to detect damage in steel moment-frame buildings following an earthquake, evaluating the damaged buildings to determine their safety in the postearthquake environment, and repairing damaged buildings. The recommended design criteria contained in these three companion reports are based on the material and workmanship standards contained in this document, which also includes discussion of the basis for the quality control and quality assurance criteria contained in the recommended specifications.

Primer for design professionals

Primer for design professionals PDF Author:
Publisher:
ISBN:
Category : Commercial buildings
Languages : en
Pages : 198

Get Book Here

Book Description