Work Plan for an Engineering Evaluation/Cost Analysis for Hill Air Force Base, Ogden, Utah

Work Plan for an Engineering Evaluation/Cost Analysis for Hill Air Force Base, Ogden, Utah PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 95

Get Book Here

Book Description
This work plan was prepared by Engineering-Science, Inc. (ES) and presents the scope of work required for the collection of data necessary to conduct an engineering evaluation/cost analysis (EB/CA) for remediation of fuel hydrocarbon-contaminated ground water at underground storage tank (UST) Site 870, Hill Air Force Base (AFB), Utah. Several remedial options will be evaluated during the EE/CA, including free product removal; ground water extraction, treatment, and reinjection (i.e., pump and treat); air sparging; and natural contaminant attenuation with long-term monitoring. All hydrogeologic and ground water chemical data necessary to evaluate the various remedial options will be collected under this program; however, this work plan is oriented toward the collection of hydrogeologic data to be used as input into the Bioplume II ground water model in support of the natural attenuation (intrinsic remediation) with long-term monitoring remedial option for restoration of fuel hydrocarbon-contaminated ground water.

Work Plan for an Engineering Evaluation/Cost Analysis for Hill Air Force Base, Ogden, Utah

Work Plan for an Engineering Evaluation/Cost Analysis for Hill Air Force Base, Ogden, Utah PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 95

Get Book Here

Book Description
This work plan was prepared by Engineering-Science, Inc. (ES) and presents the scope of work required for the collection of data necessary to conduct an engineering evaluation/cost analysis (EB/CA) for remediation of fuel hydrocarbon-contaminated ground water at underground storage tank (UST) Site 870, Hill Air Force Base (AFB), Utah. Several remedial options will be evaluated during the EE/CA, including free product removal; ground water extraction, treatment, and reinjection (i.e., pump and treat); air sparging; and natural contaminant attenuation with long-term monitoring. All hydrogeologic and ground water chemical data necessary to evaluate the various remedial options will be collected under this program; however, this work plan is oriented toward the collection of hydrogeologic data to be used as input into the Bioplume II ground water model in support of the natural attenuation (intrinsic remediation) with long-term monitoring remedial option for restoration of fuel hydrocarbon-contaminated ground water.

Final Engineering Evaluation/cost Analysis Operable Unit 6 Hill Air Force Base, Utah

Final Engineering Evaluation/cost Analysis Operable Unit 6 Hill Air Force Base, Utah PDF Author: Steve Hicken
Publisher:
ISBN:
Category : Hazardous waste sites
Languages : en
Pages :

Get Book Here

Book Description


Engineering Evaluation/cost Analysis Operable Unit 5 Hill Air Force Base, Utah

Engineering Evaluation/cost Analysis Operable Unit 5 Hill Air Force Base, Utah PDF Author: Hill Air Force Base (Utah). Environmental Management Directorate
Publisher:
ISBN:
Category : Hazardous waste sites
Languages : en
Pages :

Get Book Here

Book Description


Proposed Final

Proposed Final PDF Author:
Publisher:
ISBN:
Category : Hazardous waste sites
Languages : en
Pages :

Get Book Here

Book Description


Final Engineering Evaluation/cost Analysis for Operable Unit 2, Sites WP07, SS21 Non-source Area Seeps and Springs for Hill Air Force Base, Utah

Final Engineering Evaluation/cost Analysis for Operable Unit 2, Sites WP07, SS21 Non-source Area Seeps and Springs for Hill Air Force Base, Utah PDF Author: Radian Corporation
Publisher:
ISBN:
Category : Hazardous waste sites
Languages : en
Pages :

Get Book Here

Book Description


Final Draft Work Plan for an Engineering Evaluation/Cost Analysis to Support the Risk-Based Approach to Remediation at Site ST-27, Charleston Air Force Base, Charleston, South Carolina

Final Draft Work Plan for an Engineering Evaluation/Cost Analysis to Support the Risk-Based Approach to Remediation at Site ST-27, Charleston Air Force Base, Charleston, South Carolina PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 157

Get Book Here

Book Description
This work plan prepared by Parsons Engineering Science, Inc. (Parsons ES) describes the scope of work required for the collection and analysis of data to complete an engineering evaluation/cost analysis (BE/CA) to support a risk-based remediation decision for soil and groundwater contaminated with fuel hydrocarbons at Installation Restoration Program (lRP) Site ST-27 located at Charleston Air Force Base (AFB), Charleston, South Carolina. Soil and groundwater at Site ST-27 were impacted by petroleum hydrocarbons as a result of a leaking JP-4 jet fuel underground storage tank (UST). The site is located adjacent to aircraft maintenance hangar Building 575. This work plan is equivalent to a treatability study test design (TSTD) for field testing to support the risk-based approach for remediation of Site ST-27. This innovative technology is sponsored by the Air Force Center for Environmental Excellence (AFCEE) at Brooks AFB, Texas under contract F41624-93-C-8044, "Risk- Based Approach to Fuel Spill Remediation." The Site ST-27 risk-based field test and evaluation is a component of a multi site initiative being sponsored by AFCEE to demonstrate how quantitative fate and transport calculations and risk evaluation based on site-specific data can be integrated to quickly determine the type and magnitude of remedial action required at a site to minimize contaminant migration and receptor risks.

Work Plan for Engineering Evaluations/Cost Analyses at Hangar 10 and Site ST41, Elmendorf Air Force Base, Anchorage, Alaska

Work Plan for Engineering Evaluations/Cost Analyses at Hangar 10 and Site ST41, Elmendorf Air Force Base, Anchorage, Alaska PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 121

Get Book Here

Book Description
This work plan was prepared by Engineering-Science, Inc. (ES) and presents the scope of work required for the collection of data necessary to conduct an engineering evaluation/cost analysis (EE/CA) for remediation of fuel-hydrocarbon-contaminated ground water at two sites at Elmendorf Air Force Base (AFB), Anchorage, Alaska. The two sites to be addressed are the Hangar 10 site and site ST4l (locally known as Four Million Gallon Hill). Several remedial options will be evaluated during the EE/CA, including free product removal; ground water extraction, treatment, and re-injection (i.e., pump and treat); air sparging; and intrinsic remediation with long-term monitoring (intrinsic remediation). All hydrogeologic and ground water chemical data necessary to evaluate the various remedial options will be collected under this program; however, this work plan is oriented toward the collection of hydrogeologic data to be used as input into the Bioplume II ground water model in support of the intrinsic remediation (intrinsic remediation) with long-term monitoring remedial option for restoration of fuel hydrocarbon-contaminated ground water.

Department of Defense Appropriations

Department of Defense Appropriations PDF Author: United States. Congress. Senate. Committee on Appropriations
Publisher:
ISBN:
Category :
Languages : en
Pages : 1744

Get Book Here

Book Description


Draft Work Plan for an Engineering Evaluation/Cost Analysis in Support of the Risk-Based Approach to Remediation at Pumphouse Number 2. Malmstrom Air Force Base, Great Falls, Montana

Draft Work Plan for an Engineering Evaluation/Cost Analysis in Support of the Risk-Based Approach to Remediation at Pumphouse Number 2. Malmstrom Air Force Base, Great Falls, Montana PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 139

Get Book Here

Book Description
This work plan was prepared by Engineering-Science, Inc. (ES) and describes the scope of work required for the collection and analysis of data to complete an engineering evaluation/cost analysis (EE/CA) in support of a risk-based remediation decision for soil and ground water contaminated with fuel hydrocarbons at Pumphouse #2 at Malmstrom Air Force Base (AFB), Great Falls, Montana. Under the basewide Installation Restoration Program (IRP), Pumphouse #2 is a portion of Site PS-3 and may be referred to as such in referenced documents used in preparation of this work plan. This work plan is the equivalent of a treatability study test design (TSTD) for the field test of the risk-based approach to remediation at Pumphouse #2. This innovative technology is sponsored by the Air Force Center for Environmental Excellence (AFCEE) at Brooks AFB, Texas, under contract F41624-93-C-8044, "Risk-Based Approach to Fuel Spill Remediation." The Pumphouse #2 demonstration is a component of a multi-site initiative being sponsored by AFCEE to demonstrate how quantitative fate and transport calculations and risk information based on site-specific data can be integrated to quickly determine the type and magnitude of remedial action required at a site to minimize contaminant migration and receptor risks.

Final Work Plan for an Engineering Evaluation/Cost Analysis in Support of the Risk-Based Approach to Remediation at Area D, Ellsworth Air Base, Rapid City, South Dakota

Final Work Plan for an Engineering Evaluation/Cost Analysis in Support of the Risk-Based Approach to Remediation at Area D, Ellsworth Air Base, Rapid City, South Dakota PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 127

Get Book Here

Book Description
This work plan was prepared by Engineering Science, Inc. (ES) and describes the scope of work required for the collection and analysis of data to complete an engineering evaluation/cost analysis (EE/CA) in support of a risk-based remediation decision for soil and ground water contaminated with fuel hydrocarbons at Area D Bulk Fuel Storage (Area D) at Ellsworth Air Force Base (AFB), Rapid City, South Dakota. Area D, a petroleum, oil, and lubricant (POL) tank farm, is part of the base-wide fuel distribution system. This work plan is the equivalent of a treatability study test design (TSTD) for the field test of the risk-based approach to the remediation of Area D. This innovative technology is sponsored by the Air Force Center for Environmental Excellence (AFCEE) at Brooks AFB, under contract F41624-93-C-8044, "Risk-Based Approach to Fuel Spill Remediation." The Area D demonstration is a component of a multisite initiative being sponsored by AFCEE to demonstrate how quantitative fate and transport calculations and risk information based on site-specific data can be integrated to quickly determine the type and magnitude of remedial action required at a site to minimize contaminant migration and receptor risks.