USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers PDF Author: N.A. Leidel
Publisher:
ISBN:
Category :
Languages : en
Pages : 97

Get Book Here

Book Description

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers PDF Author: National Institute for Occupational Safety and Health
Publisher:
ISBN:
Category : Asbestos
Languages : en
Pages : 104

Get Book Here

Book Description


USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers PDF Author: N.A. Leidel
Publisher:
ISBN:
Category :
Languages : en
Pages : 97

Get Book Here

Book Description


USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbestos Fibers PDF Author: Nelson A. Leidel
Publisher:
ISBN:
Category :
Languages : en
Pages : 89

Get Book Here

Book Description


NIOSH Analytical Method # P & CAM 239

NIOSH Analytical Method # P & CAM 239 PDF Author: Nelson A. Leidel
Publisher:
ISBN:
Category : Asbestos
Languages : en
Pages : 62

Get Book Here

Book Description


USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbetos Fibers

USPHS/NIOSH Membrane Filter Method for Evaluating Airborne Asbetos Fibers PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 89

Get Book Here

Book Description


Asbestos Publications Produced by the National Institute for Occupational Safety and Health (NIOSH)

Asbestos Publications Produced by the National Institute for Occupational Safety and Health (NIOSH) PDF Author: DIANE Publishing Company
Publisher: DIANE Publishing
ISBN: 0788135597
Category :
Languages : en
Pages : 197

Get Book Here

Book Description
Consists of full-text or abstracted copies of selected National Institute for Occupational Safety and Health (NIOSH) documents on asbestos. They include NIOSH publications and testimony that summarize both NIOSH research on the health hazards of asbestos and NIOSH recommendations on workplace exposure to asbestos. Also contains a complete list of NIOSH documents on asbestos. The citations are arranged alphabetically by document title or author within one of the following 6 categories: numbered publications, testimony, journal articles and conference proceedings, contract reports, grant reports, and miscellaneous reports.

Membrane Filter Method for Estimating Asbestos Fiber Exposure

Membrane Filter Method for Estimating Asbestos Fiber Exposure PDF Author: AG. Wylie
Publisher:
ISBN:
Category : Asbestos
Languages : en
Pages : 13

Get Book Here

Book Description
Asbestos exposure is usually evaluated by the membrane filter method recommended by the National Institute for Occupational Safety and Health (NIOSH). The method for estimating fiber exposure was originally applied only to environments in which commercially mined asbestos was being used, but it has now been extended to the mining environment and to other environments in which natural materials containing small quantities of asbestos are found. It has been incorporated into state regulations and procedures and adopted by the industrial hygiene community as an appropriate way to evaluate asbestos exposure. Nonetheless, the membrane filter method suffers from the following serious deficiencies: (1) The aspect ratio criterion used to define and count mineral fibers was arbitrarily chosen and has never been shown to have any relevance to the etiology of asbestos-related diseases or to the actual dimensions of airborne asbestos fibers. (2) Common cleavage fragments of many amphiboles are regulated as asbestos. (3) Many fabricated products containing asbestos and many ores that may contain small quantities of asbestos also contain other substances that cannot be distinguished from asbestos by the membrane filter method. (4) Most airborne asbestos fibers are invisible if the membrane filter method is used. (5) There is no predictable relationship between exposure estimates based on the membrane filter method and the total airborne fiber concentration, as established by electron microscopy. The ratio varies between these two estimates of exposure according to (a) the particular asbestos mineral being evaluated, (b) the degree of development of the asbestiform habit, and (c) the degree of processing to which the mineral has been subjected. Therefore, different total exposures are allowed under existing regulations for different minerals, different mineral habits, and different work environments. A revised standard based on electron microscopy and applying appropriate dimensional criteria is recommended.

Sampling and Evaluating Airborne Asbestos Dust (582).

Sampling and Evaluating Airborne Asbestos Dust (582). PDF Author:
Publisher:
ISBN:
Category : Asbestos dust
Languages : en
Pages : 232

Get Book Here

Book Description


NIOSH Manual of Analytical Methods

NIOSH Manual of Analytical Methods PDF Author:
Publisher:
ISBN:
Category : Chemistry, Analytic
Languages : en
Pages : 948

Get Book Here

Book Description


NIOSH, Manual of Analytical Methods

NIOSH, Manual of Analytical Methods PDF Author: National Institute for Occupational Safety and Health. Division of Physical Sciences and Engineering
Publisher:
ISBN:
Category : Chemicals
Languages : en
Pages : 688

Get Book Here

Book Description