Performance Evaluation of a Real-time Aerosol Monitor

Performance Evaluation of a Real-time Aerosol Monitor PDF Author: Kenneth L. Williams
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 28

Get Book Here

Book Description
The Bureau of Mines laboratory tested the response of a commercially available real-time aerosol monitor (GCA RAM-I) to various dusts. Monitor measurements were recorded, averaged, and compared with simultaneous gravimetric measurements of each test dust. Tests usually lasted several hours. The test dusts of various particle size distributions used included coal, limestone, and a commercially available test dust. For each particular dust, the monitor response was linear and correlated well with mass concentration over the range of about 0.5 to 10 mg/ma3 The monitor can estimate a 2.0-mg/m3 respirable coal dust concentration within as little as ± 6 pet with 95 pet confidence. The monitor must, however, be calibrated with the dust to be measured because the instrument response is affected by the type of dust particle. The average monitor response to a mass concentration of coal dust was approximately twice the average monitor response to the same mass concentration of limestone dust.

Performance Evaluation of a Real-time Aerosol Monitor

Performance Evaluation of a Real-time Aerosol Monitor PDF Author: Kenneth L. Williams
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 28

Get Book Here

Book Description
The Bureau of Mines laboratory tested the response of a commercially available real-time aerosol monitor (GCA RAM-I) to various dusts. Monitor measurements were recorded, averaged, and compared with simultaneous gravimetric measurements of each test dust. Tests usually lasted several hours. The test dusts of various particle size distributions used included coal, limestone, and a commercially available test dust. For each particular dust, the monitor response was linear and correlated well with mass concentration over the range of about 0.5 to 10 mg/ma3 The monitor can estimate a 2.0-mg/m3 respirable coal dust concentration within as little as ± 6 pet with 95 pet confidence. The monitor must, however, be calibrated with the dust to be measured because the instrument response is affected by the type of dust particle. The average monitor response to a mass concentration of coal dust was approximately twice the average monitor response to the same mass concentration of limestone dust.

Performance Evaluation of a Real-time Aerosol Monitor

Performance Evaluation of a Real-time Aerosol Monitor PDF Author: Kenneth L. Williams
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 20

Get Book Here

Book Description


Evaluation of a Passive Real-time Miniature Aerosol Monitor

Evaluation of a Passive Real-time Miniature Aerosol Monitor PDF Author: Sidney DeGarmo (James)
Publisher:
ISBN:
Category :
Languages : en
Pages : 202

Get Book Here

Book Description


Evaluation of TEOM Dust Monitor

Evaluation of TEOM Dust Monitor PDF Author: Kenneth L. Williams
Publisher:
ISBN:
Category : Mine dusts
Languages : en
Pages : 24

Get Book Here

Book Description


Performance Evaluation of Two Light-scattering Dust Monitors

Performance Evaluation of Two Light-scattering Dust Monitors PDF Author: Robert P. Vinson
Publisher:
ISBN:
Category : Engineering geology
Languages : en
Pages : 24

Get Book Here

Book Description


Monthly Catalogue, United States Public Documents

Monthly Catalogue, United States Public Documents PDF Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1252

Get Book Here

Book Description


Monthly Catalog of United States Government Publications

Monthly Catalog of United States Government Publications PDF Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages :

Get Book Here

Book Description


The Effect of Water Vapor and Water Droplets on the RAM-1

The Effect of Water Vapor and Water Droplets on the RAM-1 PDF Author: Robert P. Vinson
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 20

Get Book Here

Book Description


Underground Mine Communications, Control and Monitoring

Underground Mine Communications, Control and Monitoring PDF Author:
Publisher:
ISBN:
Category : Mine communication systems
Languages : en
Pages : 530

Get Book Here

Book Description


Information Circular

Information Circular PDF Author:
Publisher:
ISBN:
Category : Mines and mineral resources
Languages : en
Pages : 420

Get Book Here

Book Description