Author: United States. Mining Enforcement and Safety Administration
Publisher:
ISBN:
Category : Breathing apparatus
Languages : en
Pages : 66
Book Description
Gravimetric Mass Respirable Dust Sampling
Author: United States. Mining Enforcement and Safety Administration
Publisher:
ISBN:
Category : Breathing apparatus
Languages : en
Pages : 66
Book Description
Publisher:
ISBN:
Category : Breathing apparatus
Languages : en
Pages : 66
Book Description
Comparison of Respirable Dust Concentrations Measured with Personal Gravimetric Sampling Instruments Operated On-section and Portal-to-portal
Author: Thomas F. Tomb
Publisher:
ISBN:
Category : Coal dust
Languages : en
Pages : 16
Book Description
Publisher:
ISBN:
Category : Coal dust
Languages : en
Pages : 16
Book Description
Gravimetric Mass Repirable Dust Sampling
Author:
Publisher:
ISBN:
Category : Dust sampling
Languages : en
Pages : 57
Book Description
Publisher:
ISBN:
Category : Dust sampling
Languages : en
Pages : 57
Book Description
General Methods for Sampling and Gravimetric Analysis of Respirable and Total Inhalable Dust
Author:
Publisher:
ISBN: 9780717617494
Category : Dust control
Languages : en
Pages : 12
Book Description
General Methods for Sampling and Gravimetric Analysis of Respirable and Total Inhalable Dust
Publisher:
ISBN: 9780717617494
Category : Dust control
Languages : en
Pages : 12
Book Description
General Methods for Sampling and Gravimetric Analysis of Respirable and Total Inhalable Dust
Comparison of Surface Coal Mine Respirable Dust Concentrations Measured with MRE and Personal Gravimetric Sampling Equipment
Author:
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 20
Book Description
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 20
Book Description
Comparison of Respirable Dust Concentrations Measured with MRE and Modified Personal Gravimetric Sampling Equipment
Author:
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 40
Book Description
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 40
Book Description
The Gravimetric Sampling of Respirable Dust
Author: R. J. Hamilton
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 11
Book Description
Publisher:
ISBN:
Category : Coal mines and mining
Languages : en
Pages : 11
Book Description
Workplace Atmospheres
Author: Standards Association of Australia. Committee CH/31, Workplace Atmospheres
Publisher:
ISBN: 9780726246937
Category : Air
Languages : en
Pages : 8
Book Description
Publisher:
ISBN: 9780726246937
Category : Air
Languages : en
Pages : 8
Book Description
Performance Evaluation of a Real-time Aerosol Monitor
Author: Kenneth L. Williams
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 28
Book Description
The Bureau of Mines laboratory tested the response of a commercially available real-time aerosol monitor (GCA RAM-I) to various dusts. Monitor measurements were recorded, averaged, and compared with simultaneous gravimetric measurements of each test dust. Tests usually lasted several hours. The test dusts of various particle size distributions used included coal, limestone, and a commercially available test dust. For each particular dust, the monitor response was linear and correlated well with mass concentration over the range of about 0.5 to 10 mg/ma3 The monitor can estimate a 2.0-mg/m3 respirable coal dust concentration within as little as ± 6 pet with 95 pet confidence. The monitor must, however, be calibrated with the dust to be measured because the instrument response is affected by the type of dust particle. The average monitor response to a mass concentration of coal dust was approximately twice the average monitor response to the same mass concentration of limestone dust.
Publisher:
ISBN:
Category : Aerosols
Languages : en
Pages : 28
Book Description
The Bureau of Mines laboratory tested the response of a commercially available real-time aerosol monitor (GCA RAM-I) to various dusts. Monitor measurements were recorded, averaged, and compared with simultaneous gravimetric measurements of each test dust. Tests usually lasted several hours. The test dusts of various particle size distributions used included coal, limestone, and a commercially available test dust. For each particular dust, the monitor response was linear and correlated well with mass concentration over the range of about 0.5 to 10 mg/ma3 The monitor can estimate a 2.0-mg/m3 respirable coal dust concentration within as little as ± 6 pet with 95 pet confidence. The monitor must, however, be calibrated with the dust to be measured because the instrument response is affected by the type of dust particle. The average monitor response to a mass concentration of coal dust was approximately twice the average monitor response to the same mass concentration of limestone dust.
AS 2985
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description