ETUDES SUR TISSUS SAINS ET IRRADIES UTILISANT L'IMAGERIE DE RESONANCE MAGNETIQUE NUCLEAIRE A HAUTE RESOLUTION SPATIALE

ETUDES SUR TISSUS SAINS ET IRRADIES UTILISANT L'IMAGERIE DE RESONANCE MAGNETIQUE NUCLEAIRE A HAUTE RESOLUTION SPATIALE PDF Author: ALAIN.. CHALANSONNET
Publisher:
ISBN:
Category :
Languages : fr
Pages : 180

Get Book Here

Book Description
LES OBJECTIFS DE CETTE THESE ONT ETE (1) DE TRAVAILLER EN HAUTE RESOLUTION SPATIALE EN IMAGERIE RMN, (2) D'APPLIQUER CETTE TECHNIQUE AU CAS DU TISSU CUTANE, (3) DE DETECTER PAR RMN DES EFFETS PRECOCES D'UNE IRRADIATION LOCALISEE SUR LA PEAU A PARTIR DE MODELES ANIMAUX. LA THESE SE DECOMPOSE EN TROIS PARTIES. LA PREMIERE DECRIT UNE APPLICATION DE LA RMN A LA DOSIMETRIE SUR UN MODELE EQUIVALENT-TISSU (SOLUTION DE FRICKE-INCORPOREE DANS UN GEL D'AGAROSE). LES OBSERVATIONS PAR MESURE DU TEMPS DE RELAXATION LONGITUDINAL T1, ET D'INTENSITE DU SIGNAL MONTRENT, POUR CES MODELES IRRADIES AU COBALT 60 ET A L'IRIDIUM 192, UNE LOI LINEAIRE DOSE-EFFETS. LA SECONDE PARTIE REGROUPE UNE ETUDE DE PEAU IRRADIEE REALISEE IN VIVO(PORC) SUR UN IMAGEUR CLINIQUE DEMONTRANT LA NECESSITE DE PASSER A DES OBSERVATIONS DE MICROSCOPIE PAR IRM. CES EXPERIENCES ONT ETE MISES AU POINT SUR UN SYSTEME EXPERIMENTAL OPERANT AVEC UN CHAMP DE 2 TESLA. LES ANALYSES EFFECTUEES SUR BIOPSIES AVEC UNE RESOLUTION DE L'ORDRE DE 40 MICRONS PAR PIXEL DANS LA DIRECTION PERPENDICULAIRE AU PLAN CUTANE ONT MONTRE QUE L'ON POUVAIT DETECTER DES ANOMALIES AU BOUT DE 48 H, POUR UNE DOSE DE 64 GY. LA TROISIEME PARTIE CONSISTE A AMELIORER LE CONTRASTE PAR DEUX TECHNIQUES DE TRANSFERT D'AIMANTATION ET MONTRE UNE SUPERIORITE DE L'APPROCHE T2 SELECTIVE PAR RAPPORT A UNE METHODE CLASSIQUE DE SATURATION HORS RESONANCE. L'INTERET DE L'ENSEMBLE DE CE TRAVAIL RESIDE DANS SA CONTRIBUTION A LA RECHERCHE DE MOYENS DE DETECTION PRECOCE DES EFFETS DE RAYONNEMENTS IONISANTS

ETUDES SUR TISSUS SAINS ET IRRADIES UTILISANT L'IMAGERIE DE RESONANCE MAGNETIQUE NUCLEAIRE A HAUTE RESOLUTION SPATIALE

ETUDES SUR TISSUS SAINS ET IRRADIES UTILISANT L'IMAGERIE DE RESONANCE MAGNETIQUE NUCLEAIRE A HAUTE RESOLUTION SPATIALE PDF Author: ALAIN.. CHALANSONNET
Publisher:
ISBN:
Category :
Languages : fr
Pages : 180

Get Book Here

Book Description
LES OBJECTIFS DE CETTE THESE ONT ETE (1) DE TRAVAILLER EN HAUTE RESOLUTION SPATIALE EN IMAGERIE RMN, (2) D'APPLIQUER CETTE TECHNIQUE AU CAS DU TISSU CUTANE, (3) DE DETECTER PAR RMN DES EFFETS PRECOCES D'UNE IRRADIATION LOCALISEE SUR LA PEAU A PARTIR DE MODELES ANIMAUX. LA THESE SE DECOMPOSE EN TROIS PARTIES. LA PREMIERE DECRIT UNE APPLICATION DE LA RMN A LA DOSIMETRIE SUR UN MODELE EQUIVALENT-TISSU (SOLUTION DE FRICKE-INCORPOREE DANS UN GEL D'AGAROSE). LES OBSERVATIONS PAR MESURE DU TEMPS DE RELAXATION LONGITUDINAL T1, ET D'INTENSITE DU SIGNAL MONTRENT, POUR CES MODELES IRRADIES AU COBALT 60 ET A L'IRIDIUM 192, UNE LOI LINEAIRE DOSE-EFFETS. LA SECONDE PARTIE REGROUPE UNE ETUDE DE PEAU IRRADIEE REALISEE IN VIVO(PORC) SUR UN IMAGEUR CLINIQUE DEMONTRANT LA NECESSITE DE PASSER A DES OBSERVATIONS DE MICROSCOPIE PAR IRM. CES EXPERIENCES ONT ETE MISES AU POINT SUR UN SYSTEME EXPERIMENTAL OPERANT AVEC UN CHAMP DE 2 TESLA. LES ANALYSES EFFECTUEES SUR BIOPSIES AVEC UNE RESOLUTION DE L'ORDRE DE 40 MICRONS PAR PIXEL DANS LA DIRECTION PERPENDICULAIRE AU PLAN CUTANE ONT MONTRE QUE L'ON POUVAIT DETECTER DES ANOMALIES AU BOUT DE 48 H, POUR UNE DOSE DE 64 GY. LA TROISIEME PARTIE CONSISTE A AMELIORER LE CONTRASTE PAR DEUX TECHNIQUES DE TRANSFERT D'AIMANTATION ET MONTRE UNE SUPERIORITE DE L'APPROCHE T2 SELECTIVE PAR RAPPORT A UNE METHODE CLASSIQUE DE SATURATION HORS RESONANCE. L'INTERET DE L'ENSEMBLE DE CE TRAVAIL RESIDE DANS SA CONTRIBUTION A LA RECHERCHE DE MOYENS DE DETECTION PRECOCE DES EFFETS DE RAYONNEMENTS IONISANTS

SPECTROSCOPIE PAR RESONANCE MAGNETIQUE NUCLEAIRE HAUTE RESOLUTION DE TISSUS CUTANES IN VITRO. ETUDE DES EFFETS D'IRRADIATIONS IONISANTES

SPECTROSCOPIE PAR RESONANCE MAGNETIQUE NUCLEAIRE HAUTE RESOLUTION DE TISSUS CUTANES IN VITRO. ETUDE DES EFFETS D'IRRADIATIONS IONISANTES PDF Author: JEAN-LUC.. BONNAT
Publisher:
ISBN:
Category :
Languages : fr
Pages : 161

Get Book Here

Book Description
DES RESULTATS OBTENUS AU LABORATOIRE EN IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE (RMN) DE LA PEAU (VISUALISATION DE ZONES IRRADIEES) ONT CONDUIT A POURSUIVRE CES ETUDES PAR SPECTROSCOPIE DE RMN HAUTE RESOLUTION. LE BUT ETAIT D'ETUDIER LA RELATION ENTRE TENEUR EN METABOLITES ET DOSE D'IRRADIATION IONISANTE. LE PREMIER CHAPITRE RASSEMBLE LES CONNAISSANCES PHYSIOLOGIQUES SUR LA PEAU ET SA REACTION LORS D'UNE IRRADIATION. LES METHODES DE RADIO-DOSIMETRIE ET DE SUIVI THERAPEUTIQUE D'ORGANES IRRADIES SONT MENTIONNEES DANS UNE REVUE ET L'UTILISATION DE LA RMN EST DETAILLEE. DANS LE DEUXIEME CHAPITRE SONT DECRITS LES PROTOCOLES BIOCHIMIQUES MIS AU POINT POUR LA PREPARATION DES ECHANTILLONS EN VUE DE L'ANALYSE RMN. L'ETUDE IN VITRO SE LIMITE AUX METABOLITES LIBRES EXTRAITS PAR ACIDE PERCHLORIQUE ET CENTRIFUGATION. LE TROISIEME CHAPITRE EXPOSE LES TECHNIQUES DE RMN EMPLOYEES : SPECTROSCOPIE A DEUX DIMENSIONS (COSY, TOCSY ET J-RESOLUE) POUR ETABLIR LA COMPOSITION DES ECHANTILLONS, ET A UNE DIMENSION POUR LES QUANTIFICATIONS DES VARIATIONS RADIO-INDUITES. CES QUANTIFICATIONS SONT REALISEES PAR L'ALGORITHME DE TRAITEMENT DU SIGNAL VARPRO (PARTIE DU LOGICIEL MRUI DEVELOPPE AU LABORATOIRE) QUI PERMET D'OPERER DANS LE DOMAINE TEMPOREL. CETTE PREMIERE APPLICATION SUR DES DONNEES HAUTE RESOLUTION A PERMIS D'EN APPRECIER LES POSSIBILITES ET LES LIMITES POUR L'ANALYSE DE SPECTRES COMPLEXES ABONDANTS EN SIGNAUX. DANS LE QUATRIEME CHAPITRE SONT PRESENTEES LA COMPOSITION EN METABOLITES DES ECHANTILLONS, EN PROTON ET PHOSPHORE, ET LES QUANTIFICATIONS DES SPECTRES DE TISSUS SAINS ET IRRADIES. LES VARIATIONS OBSERVEES SONT DE FAIBLE AMPLITUDE ET DEPENDENT DES INDIVIDUS ET DU RAYONNEMENT APPLIQUE. ENTRE DEUX ZONES TEMOINS D'UN MEME INDIVIDU LES RAPPORT LAC/ALA, LAC/AC OU ALA/AC FLUCTUENT DE 20% A 70%. VINGT ET UN JOURS APRES UNE IRRADIATION LE RAPPORT LAC/AC DIMINUE PAR RAPPORT AUX TEMOINS D'ENVIRON 50%. MAIS POUR LES AUTRES RAPPORTS, ET POUR L'IRRADIATION , LES MODIFICATIONS SONT SIMILAIRES AUX VARIATIONS INTRA-INDIVIDUELLES. CETTE FORTE VARIABILITE INTRA-INDIVIDUELLE LIMITE DONC L'ETABLISSEMENT DE CRITERES D'EVALUATION DE LA LESION, MALGRE LA TENDANCE DONNEE PAR LE RAPPORT LAC/AC. CETTE ETUDE CONFIRME UNE CERTAINE SUPERIORITE DE L'APPROCHE FONDEE SUR L'IMAGERIE POUR LA CARACTERISATION PAR RMN DES RADIOLESIONS.

PERSPECTIVES D'UTILISATION DE L'IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE

PERSPECTIVES D'UTILISATION DE L'IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE PDF Author: FRANCOIS.. HUSSON
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
A PARTIR DE L'EXPRESSION DU SIGNAL DES SEQUENCES FLASH (FAST LOW ANGLE SHOT) ET FISP (FAST IMAGING WITH STEADY PROCESSION), UNE ETUDE DU CONTRASTE EST DEVELOPPEE DANS LA PERSPECTIVE DE L'UTILISATION DES SEQUENCES RAPIDES D'IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE. L'IMAGERIE RAPIDE OFFRE D'INTERESSANTES POSSIBILITES D'INVESTIGATION, MAIS TOUTEFOIS, UN CONTRASTE REDUIT PAR RAPPORT AUX SEQUENCES CONVENTIONNELLES D'ECHO DE SPIN. PAR AILLEURS, LES INFILTRATIONS LIPIDIQUES AU SEIN DU CORPS VERTEBRAL ONT ETE DETERMINEES PAR DECOMPOSITION SPECTRALE ET ANALYSE MULTI-EXPONENTIELLE DE LA RELAXATION LONGITUDINALE. LES VALEURS EXPERIMENTALES DE T1 ET T2 OBTENUES CHES LA SOURIS IRRADIEE MONTRENT UNE FORTE DIMINUTION DES TEMPS DE RELAXATION AU NIVEAU DE LA RATE

METHODOLOGIE ET INSTRUMENTATION POUR L'ETUDE DE TISSUS BIOLOGIQUES PAR RESONANCE MAGNETIQUE

METHODOLOGIE ET INSTRUMENTATION POUR L'ETUDE DE TISSUS BIOLOGIQUES PAR RESONANCE MAGNETIQUE PDF Author: LATIFA.. FAKRI
Publisher:
ISBN:
Category :
Languages : fr
Pages : 221

Get Book Here

Book Description
CE TRAVAIL FAIT PARTIE DE LA MISE EN PLACE D'UNE INSTALLATION EXPERIMENTALE D'IMAGERIE RMN A 2 TESLA DONT LA PLUS IMPORTANTE UTILISATION EST EFFECTUEE DANS LE DOMAINE DES BIOMATERIAUX (IMAGERIE HAUTE DEFINITION SPATIALE) ET DE LA BIOMECANIQUE (IMAGERIE D'ARTICULATIONS). LE PREMIER CHAPITRE DONNE UNE DESCRIPTION ET PRECISE A PARTIR D'EXEMPLES ORIGINAUX, L'EMPLOI DE L'ENSEMBLE DU DISPOSITIF QUI A DU ETRE COMPLETE PAR LA CONSTRUCTION DES RESONATEURS, CAPTEURS DESTINES AUX OBSERVATIONS PAR IRM 1,2. LE SECOND CHAPITRE APPROFONDIT PLUSIEURS NOTIONS INDISPENSABLES A LA TECHNIQUE DE CONSTRUCTION DES ANTENNES RMN: EVOLUTION DU RAPPORT SIGNAL SUR BRUIT A TRAVERS LA CHAINE D'ACQUISITION, EQUILIBRAGE ELECTRIQUE (BALUNS), CARACTERISATION DU CHAMP RADIOFREQUENCE PAR MODELISATION PAR MESURE ET PAR IMAGERIE. SONT ENSUITE DECRITES PLUSIEURS STRUCTURES D'ANTENNES REALISEES POUR L'IMAGERIE DE BIOMATERIAUX A 2 TESLA, ET EN PARTICULIER POUR L'IMAGERIE A HAUTE RESOLUTION SPATIALE DE L'ARTICULATION DE LA CHEVILLE CHEZ LE RAT IN VIVO 3,4,5: CE TRAVAIL A PERMIS D'ETABLIR DES CORRELATIONS ENTRE IMAGES RMN ET DONNEES HISTOLOGIQUES DANS LE CAS DE TENDONS SAINS ET PATHOLOGIQUES PUIS DE LANCER UNE ETUDE DU SUIVI DE L'ACTION ANTI-INFLAMMATOIRE D'ANTIBIOTIQUES 6. PARALLELEMENT UN TRAVAIL SUR LA STRUCTURE DES RESONATEURS TYPE ALDERMAN ET GRANT A CONDUIT A LA REALISATION D'UN CAPTEUR RPE POUR LA DETECTION A CHAMP FAIBLE DE RADICAUX LIBRES DANS LES EXTREMITES 7,8 ET DONT L'UTILISATION EST EGALEMENT ENVISAGEE DANS LE CAS D'INFLAMMATIONS ARTICULAIRES. LE QUATRIEME CHAPITRE EST CONSACRE A L'ETUDE ET A LA REALISATION D'UN NOUVEAU TYPE DE RESONATEUR FONDE SUR LA STRUCTURE DE CAGE D'OISEAU A ELEMENTS LIBRES. L'ANALYSE ET LA MODELISATION COMPLETE DU DISPOSITIF SONT PRESENTEES AINSI QU'UNE APPLICATION DANS LE DOMAINE BIOMECANIQUE ARTICULAIRE AVEC DES IMAGES DU POIGNET ET DE L'AVANT BRAS CHEZ L'HOMME

MODULE A BOBINAGES DE GRADIENTS PLATS TRIDIMENSIONNELS ET A ANTENNE REFROIDIE POUR L'IRM A HAUTE RESOLUTION SPATIALE

MODULE A BOBINAGES DE GRADIENTS PLATS TRIDIMENSIONNELS ET A ANTENNE REFROIDIE POUR L'IRM A HAUTE RESOLUTION SPATIALE PDF Author: ODILE.. COEUR-JOLY
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
CE TRAVAIL PRESENTE LA MISE EN UVRE DE L'IMAGERIE A HAUTE RESOLUTION SPATIALE SUR UN IMAGEUR PAR RESONANCE MAGNETIQUE NUCLEAIRE A 0,1 TESLA. LE BUT EST D'OBTENIR DES IMAGES DE LA SURFACE DU CORPS HUMAIN IN VIVO, AVEC UNE RESOLUTION SPATIALE DE 100 MICRONS, TOUT EN CONSERVANT UNE BONNE QUALITE D'IMAGE. L'INTENSITE DU CHAMP MAGNETIQUE DE L'IMAGEUR ETANT FAIBLE, LA SENSIBILITE DE L'APPAREIL EST INSUFFISANTE POUR OBTENIR DES IMAGES A HAUTE RESOLUTION AYANT UN BON RAPPORT SIGNAL SUR BRUIT. LA SOLUTION ADOPTEE DANS CE TRAVAIL A CONSISTE A DEVELOPPER UN MODULE SPECIFIQUE POUR LA HAUTE RESOLUTION, QUI PEUT SE CONNECTER EN OPTION SUR L'IMAGEUR DE DEPART. LE MODULE COMPREND UN SYSTEME DE GRADIENTS DE CHAMP MAGNETIQUE PLAT, QUI CONSERVE UN LARGE ACCES DU PATIENT DANS L'IMAGEUR, ET QUI PRODUIT DES INTENSITES DE GRADIENTS SUPERIEURES AU SYSTEMES STANDARD, AVEC DES TEMPS DE COMMUTATION PLUS COURTS. LES ANTENNES DE RECEPTION RADIOFREQUENCE, EGALEMENT INTEGREES DANS LE MODULE, SONT REFROIDIES A LA TEMPERATURE DE L'AZOTE LIQUIDE POUR DIMINUER LEUR BRUIT. DEUX TYPES D'ANTENNES SONT DECRITES: DES ANTENNES EN CUIVRE ET DES ANTENNES EN MATERIAU SUPRACONDUCTEUR A HAUTE TEMPERATURE CRITIQUE. LES SEQUENCES D'IMAGERIE UTILISEES AVEC CE MODULE SONT DES SEQUENCES D'IMAGERIE RAPIDE REFOCALISEES, DONT LA FORTE SENSIBILITE AUX DEFAUTS D'HOMOGENEITE DU CHAMP PRINCIPAL EST REDUITE DANS LE CAS DES CHAMPS DE VUE FAIBLES DE LA HAUTE RESOLUTION. DES IMAGES A HAUTE RESOLUTION SPATIALE DU POIGNET, DE L'IL, ET DE LA PEAU DU CORPS HUMAIN, OBTENUES A 0,1 T AVEC LE MODULE HAUTE RESOLUTION, SONT PRESENTEES. DES STRUCTURES DE 100 MICRONS, VISUALISEES SUR DES IMAGES DE LA PEAU DU DOS IN VIVO, VALIDENT LES POSSIBILITES ET LA QUALITE DES IMAGES FOURNIES PAR LE MODULE

IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE DES MOUVEMENTS INCOHERENTS MICROSCOPIQUES

IMAGERIE PAR RESONANCE MAGNETIQUE NUCLEAIRE DES MOUVEMENTS INCOHERENTS MICROSCOPIQUES PDF Author: Denis Le Bihan
Publisher:
ISBN:
Category :
Languages : en
Pages : 315

Get Book Here

Book Description
PROCEDE D'IMAGERIE POUR LA VISUALISATION ET LA MESURE DANS CHAQUE VOCAL DE L'IMAGE DES MOUVEMENTS INCOHERENT ET MICROSCOPIQUE

CARACTERISATION DE LA PEAU IN VIVO EN IMAGERIE PAR RESONANCE MAGNETIQUE A HAUTE RESOLUTION SPATIALE

CARACTERISATION DE LA PEAU IN VIVO EN IMAGERIE PAR RESONANCE MAGNETIQUE A HAUTE RESOLUTION SPATIALE PDF Author: Stéphanie Richard
Publisher:
ISBN:
Category :
Languages : fr
Pages : 243

Get Book Here

Book Description
NOUS PRESENTONS DANS CE MEMOIRE LES APPLICATIONS DE L'IMAGERIE PAR RESONANCE MAGNETIQUE (IRM) A L'ETUDE DE LA PEAU IN VIVO. LA HAUTE RESOLUTION SPATIALE, INDISPENSABLE POUR VISUALISER LES DIFFERENTES COUCHES DE LA PEAU, EST OBTENUE A L'AIDE D'UN MODULE SPECIALEMENT CONCU PAR LES LABORATOIRES DE RECHERCHE FONDAMENTALE A L'OREAL ET L'INSTITUT D'ELECTRONIQUE FONDAMENTALE (ORSAY), QUI A ETE ADAPTE A L'IMAGEUR CORPS ENTIER DU CENTRE INTER-ETABLISSEMENT DE RESONANCE MAGNETIQUE (CIERM). DANS UNE PREMIERE PARTIE, NOUS RAPPELONS LES BASES PHYSIQUES DE L'IRM ET NOUS DECRIVONS LA STRUCTURE DE LA PEAU AINSI QUE SA COMPOSITION. LA DEUXIEME PARTIE DU MEMOIRE EST CONSACREE A L'IMAGERIE, NOUS DECRIVONS QUELLES ONT ETE LES ETAPES DE CALIBRATION (EVALUATION DE LA RESOLUTION) ET D'OPTIMISATION DE CES IMAGES AVANT DE MONTRER QUEL TYPE D'INFORMATION EST ACCESSIBLE SUR LA PEAU SAINE POUR DIFFERENTS SITES TOPOGRAPHQIUES PUIS POUR QUELQUES CAS DE PATHOLOGIES DERMATOLOGIQUES. DANS UNE TROISIEME PARTIE, NOUS PRESENTONS L'IRM EN TANT QU'OUTIL DE CARACTERISATION TISSULAIRE APPLIQUE A L'ETUDE DE LA PEAU. LES PROTOCOLES DE MESURE DES TEMPS DE RELAXATION T1 ET T2 ET DE LA DENSITE RELATIVE DE PROTONS N(H), UNE FOIS DEFINIS ET VALIDES, NOUS ONT PERMIS DE CARACTERISER LES DIFFERENTES COUCHES DE LA PEAU IN VIVO. LE DERME EST CARACTERISE PAR DES VALEURS FAIBLES DE T2 ET DE N(H), QUI SONT LIEES A LA QUANTITE COMME A LA QUALITE DU COLLAGENE DERMIQUE. LES PREMIERS RESULTATS OBTENUS DANS LE CADRE DE L'ETUDE DU VIEILLISSEMENT MONTRENT QUE CET OUTIL, NON INVASIF, D'IMAGERIE ET DE CARACTERISATION TISSULAIRE FOURNIT DES INFORMATIONS SUSCEPTIBLES D'INTERESSER LA DERMATOLOGIE COMME LA COSMETOLOGIE

Imagerie de la peau par résonnance magnétique nucléaire à 0,1 Tesla

Imagerie de la peau par résonnance magnétique nucléaire à 0,1 Tesla PDF Author: Mohamad Mouhib Yassine
Publisher:
ISBN:
Category :
Languages : fr
Pages : 155

Get Book Here

Book Description


Reconstruction d'images de résonance magnétique à partir de l'espace k partiel

Reconstruction d'images de résonance magnétique à partir de l'espace k partiel PDF Author: Josiane Adrienne Yankam Njiwa
Publisher:
ISBN:
Category :
Languages : fr
Pages : 189

Get Book Here

Book Description
Dans le souci d'éviter les artéfacts que pourrait provoquer le mouvement sur la qualité des images, l'obtention de temps d'acquisition de données courts est essentielle en imagerie par résonance magnétique (IRM). En particulier, comme des sujets malades ont la plus part du temps des difficultés à retenir leur respiration pendant l'examen, il devient par conséquent impératif de recueillir l'information nécessaire le plus rapidement possible dans certaines études, telles que celles réalisées en imagerie cardiaque. L'acquisition partielle des données de l'espace k est une pratique couramment utilisée dans le but de diminuer le temps d'acquisition des données en IRM. La nécessité d'accélérer ce temps d'acquisition et/ou d'augmenter la résolution spatiale des images en résonance magnétique nucléaire (RMN), a conduit à la proposition de plusieurs méthodes de reconstruction qui acquièrent les données de l'espace k de façon partielle, tant pour des objets statiques que pour des objets ou études dynamiques. Ces méthodes utilisent des informations à priori (données acquises) pour retrouver celles manquantes. Ce manuscrit présente trois méthodes de reconstruction IRM utilisant les données de l'espace k acquises partiellement. La première méthode proposée est dédiée à la reconstruction d'objets ou d'organes statiques, tandis que les deux autres sont consacrées à la reconstruction d'organes dynamiques (application à l'imagerie cardiaque). Ces trois méthodes sont basées sur l'utilisation, dans l'algorithme de reconstruction, du concept d'image analytique, combinée, dans le cas des images statiques, à l'exploitation des redondances dans les données de l'espace k, et à l'utilisation des redondances temporelles associées à la substitution des données, pour les organes en mouvement. Ces méthodes ont été évaluées, dans le cadre de la reconstruction d'images statiques, par des expériences sur des images simulées auxquelles ont été rajouté un terme de phase pour la destruction de la symétrie hermitienne. On a utilisé également des fantômes physiques et de vraies images de cerveaux humains. Les deux autres méthodes ont été évaluées par des expériences sur de vraies séquences ciné cardiaques humaines. Le schéma de reconstruction proposé pour la reconstruction d'images statiques permet la réalisation d'une réduction du temps d'acquisition d'un facteur de 2. En ce qui concerne les images dynamiques, une réduction du temps d'acquisition d'un facteur de 4 a été réalisée, tout en maintenant une bonne qualité de reconstruction, tant sur le plan visuel que quantitatif (bon rapport signal sur bruit, faibles valeurs d'erreurs).

Etude du procédé de réalisation de micro-antennes souples implantables pour l'Imagerie médicale par Résonance Magnétique

Etude du procédé de réalisation de micro-antennes souples implantables pour l'Imagerie médicale par Résonance Magnétique PDF Author: Magdalèna Couty
Publisher:
ISBN:
Category :
Languages : fr
Pages : 0

Get Book Here

Book Description
L' Imagerie médicale par Résonance Magnétique (IRM) constitue un outil puissant pour le diagnostic et le suivi de pathologies dans le cadre des modèles développés sur petit animal en neurosciences. Cette application requiert une haute résolution spatiale et un Rapport Signal à Bruit(RSB) élevé, rendus possibles par l'utilisation d'un haut champ magnétique (7 T) et d'une antenne miniature à forte sensibilité, implantée à proximité de la zone d'intérêt. Le design monolithique de l'antenne, appelé Résonateur Multi-tours à Lignes de Transmission (RMLT), permet la miniaturisation en dessous du centimètre et sa réalisation par les technologies de microfabrication en salle blanche.Afin de réduire l'aspect invasif de l'implantation, l'antenne a été réalisée sur support souple :FEP Téflon® ou PDMS. Pour résoudre les problèmes d'adhérence liés à ces matériaux polymères, des traitements plasmas spécifiques ont été mis en œuvre pour le FEP Téflon® tandis qu'un procédé de transfert de motifs dédié au PDMS a été élaboré. Outre la fiabilité mécanique, l'épaisseur du revêtement PDMS assurant la bio compatibilité de l'antenne a été optimisée pour limiter le couplage diélectrique avec les tissus et ainsi conserver des caractéristiques électromagnétiques appropriées à l'IRM à 7 T lorsque l'antenne est implantée. L'ensemble de ces travaux a permis la réalisation des premières images du cerveau du rat acquises in vivo avec une micro-antenne souple implantée. Ces images ont démontré un RSB amélioré d'un facteur 5, comparées à celles acquises avec une antenne commerciale quadrature. D'autres applications et perspectives dans le domaine biomédical sont ouvertes par ces travaux comme des capteurs pour la détermination des propriétés diélectriques des tissus, et des microbobines et des capteurs de pression intégrés dans les canaux microfluidiques.