Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC PDF Author: Marianne E. Walsh
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 74

Get Book Here

Book Description
An analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC PDF Author: Marianne E. Walsh
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 74

Get Book Here

Book Description
An analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD, Comparison with HPLC.

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD, Comparison with HPLC. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
An analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.

Analytical Separation Science, 5 Volume Set

Analytical Separation Science, 5 Volume Set PDF Author: Jared Anderson
Publisher: John Wiley & Sons
ISBN: 3527333746
Category : Science
Languages : en
Pages : 2148

Get Book Here

Book Description
Endlich ein Forschungsleitfaden für Wissenschaftler des Fachgebiets, die neue Methoden entwickeln oder einsetzen. Dieses Handbuch umfasst fünf thematische Bände und bietet damit einen umfassenden Überblick über das Fachgebiet. Erläutert werden Grundlagen, die Methodenentwicklung und hochkarätige Anwendungen für alle wichtigen Analyseverfahren, darunter chromatische Verfahren, Techniken in den Bereichen Elektromigration und Membranen. Dieses Referenzwerk umfasst ein breites Spektrum und legt den Schwerpunkt auf Entwicklungen für die Zukunft. Damit ist es ein Muss für Forscher und eine wertvolle Wissensquelle für Studenten im Hauptstudium und Studienabsolventen.

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Soils Using GC-ECD

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Soils Using GC-ECD PDF Author: Marianne E. Walsh
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 52

Get Book Here

Book Description


Field Gas Chromatography/thermionic Detector System for On-site Determination of Explosives in Soils

Field Gas Chromatography/thermionic Detector System for On-site Determination of Explosives in Soils PDF Author: Alan Dole Hewitt
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 32

Get Book Here

Book Description
On-site determination of nitroaromatic, nitramine, and nitrate ester explosives compounds in soils was performed using a field-portable gas chromatograph (GC)equipped with a thermionic ionization detector (TID)selective for compounds with nitro functional groups. Soil samples were extracted with acetone. A 1 microliter volume of the filtered soil extract was manually injected into the GC, allowing for the rapid qualification and quantification of the suite of explosives that often coexist in soils at military training facilities and other defense-related sites. Good agreement was established for the concentrations of several explosives analytes when this method of analysis was compared to either high-performance liquid chromatography (Method 8330)or GC electron capture (Method 8095)analysis. Comparisons were performed for sample extracts and for soil subsample replicates distributed for on-site preparation and analysis during a field verification test performed under the auspices of the U.S. Environmental Protection Agency's Environmental Technology Verification (ETV)Program.

On-site Method for Measuring Nitroaromatic and Nitramine Explosives in Soil and Groundwater Using GC-NPD

On-site Method for Measuring Nitroaromatic and Nitramine Explosives in Soil and Groundwater Using GC-NPD PDF Author: Alan Dole Hewitt
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 24

Get Book Here

Book Description


Risk, Regulatory, and Monitoring Considerations

Risk, Regulatory, and Monitoring Considerations PDF Author: Godage B. Wickramanayake
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 456

Get Book Here

Book Description
- Regulatory Perspectives and Decision-Making- Advances in Site Characterization- Environmental Data Management, Geostatistics, and GIS- Advances in Analytical and Detection Techniques- Risk-Based Analyses for Remediation- Human Health/Ecological Risk Assessment- Technical Impracticability- Long-Term Monitoring and Optimization- Innovative Monitoring and Control Systems.

The Analysis of Explosives

The Analysis of Explosives PDF Author: Jehuda Yinon
Publisher: Elsevier
ISBN: 1483140059
Category : Technology & Engineering
Languages : en
Pages : 323

Get Book Here

Book Description
The Analysis of Explosives surveys the principles of the various analytical methods, describes how these methods are used for the analysis of explosives, and reviews the major analytical work carried out in this field. Organized into 15 chapters, this book begins with the classification of explosives. Subsequent chapters discuss the different methods for the analysis of explosives. The detection and identification of explosive residues and hidden explosives are also explained. This monograph will be useful as a reference book for chemists in analytical and forensic laboratories, as well as a textbook for graduate students in analytical chemistry and forensic sciences.

Composition and Mass Spectra of Impurities in Military Grade TNT Vapor

Composition and Mass Spectra of Impurities in Military Grade TNT Vapor PDF Author: R. P. Murrmann
Publisher:
ISBN:
Category : Dinitrotoluenes
Languages : en
Pages : 28

Get Book Here

Book Description


Modern Methods and Applications in Analysis of Explosives

Modern Methods and Applications in Analysis of Explosives PDF Author: Jehuda Yinon
Publisher: John Wiley & Sons
ISBN: 9780471965626
Category : Science
Languages : en
Pages : 320

Get Book Here

Book Description
An up-to-date handbook, with the latest advances including all the various methods and techniques for analyzing explosives. Explosive compounds and mixtures, residues--their recovery and clean-up procedures--chromatography, polarography, spectroscopy, environmental analysis and mass spectroscopy are among the topics covered.