Calibration of Voltage Transformers and High-Voltage Capacitors at Nist (Classic Reprint)

Calibration of Voltage Transformers and High-Voltage Capacitors at Nist (Classic Reprint) PDF Author: William E. Anderson
Publisher: Forgotten Books
ISBN: 9780332333335
Category : Technology & Engineering
Languages : en
Pages : 22

Get Book Here

Book Description
Excerpt from Calibration of Voltage Transformers and High-Voltage Capacitors at Nist In the past nist had used a comparative null method to calibrate voltage transformers. The un known transformer was compared to a nist refer ence transformer using a voltage comparator consisting of a variable resistive divider and a mu tual inductor. Reference transformers were avail able with ratios ranging from up to Measurement uncertainties in the comparison of the unknown transformer with the reference trans former were to.ol% for ratio and t0.3 minutes for phase angle. The ratio and phase angle of the reference transformers were known to about the same accuracy. There are several disadvantages to this approach. Since the comparator has a limited range, several reference transformers must be available to cover the anticipated users' needs. The ratio and phase angles of each one of these trans formers must be carefully determined over the secondary voltage range of interest. These trans formers then have to be rechecked at regular inter vals to determine if the ratios and phase angles have changed. If a direct measurement method were available that was sufficiently accurate and straightforward to make the calibration of these reference trans formers a simple task, then that method could be used to measure the client's transformer directly. At nist, the direct null method in use origi nally involved balancing the secondary of the ref erence transformer against the output of a resistive divider used in conjunction with a variable mutual inductor to provide phase angle balance. Such a measurement was difficult because the resistive di vider ratio changed with heating. Since the late 19605 a direct null method has been available that is straightforward and accurate and is now used at nist in place of comparative methods us ing reference transformers. Capacitors are invariably measured by balancing the unknown capacitor against a known standard using some type of bridge arrangement. There are a variety of such bridges described in the literature The one most used in high-voltage applications in the last 60 years is the Schering bridge (fig. The two high-voltage arms of this bridge consist of the standard and unknown capacitors. The two low voltage arms are resistors (one has a parallel capacitor for phase angle balance). About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Calibration of Voltage Transformers and High-Voltage Capacitors at Nist (Classic Reprint)

Calibration of Voltage Transformers and High-Voltage Capacitors at Nist (Classic Reprint) PDF Author: William E. Anderson
Publisher: Forgotten Books
ISBN: 9780332333335
Category : Technology & Engineering
Languages : en
Pages : 22

Get Book Here

Book Description
Excerpt from Calibration of Voltage Transformers and High-Voltage Capacitors at Nist In the past nist had used a comparative null method to calibrate voltage transformers. The un known transformer was compared to a nist refer ence transformer using a voltage comparator consisting of a variable resistive divider and a mu tual inductor. Reference transformers were avail able with ratios ranging from up to Measurement uncertainties in the comparison of the unknown transformer with the reference trans former were to.ol% for ratio and t0.3 minutes for phase angle. The ratio and phase angle of the reference transformers were known to about the same accuracy. There are several disadvantages to this approach. Since the comparator has a limited range, several reference transformers must be available to cover the anticipated users' needs. The ratio and phase angles of each one of these trans formers must be carefully determined over the secondary voltage range of interest. These trans formers then have to be rechecked at regular inter vals to determine if the ratios and phase angles have changed. If a direct measurement method were available that was sufficiently accurate and straightforward to make the calibration of these reference trans formers a simple task, then that method could be used to measure the client's transformer directly. At nist, the direct null method in use origi nally involved balancing the secondary of the ref erence transformer against the output of a resistive divider used in conjunction with a variable mutual inductor to provide phase angle balance. Such a measurement was difficult because the resistive di vider ratio changed with heating. Since the late 19605 a direct null method has been available that is straightforward and accurate and is now used at nist in place of comparative methods us ing reference transformers. Capacitors are invariably measured by balancing the unknown capacitor against a known standard using some type of bridge arrangement. There are a variety of such bridges described in the literature The one most used in high-voltage applications in the last 60 years is the Schering bridge (fig. The two high-voltage arms of this bridge consist of the standard and unknown capacitors. The two low voltage arms are resistors (one has a parallel capacitor for phase angle balance). About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

A Calibration Service for Voltage Transformers and High-voltage Capacitors

A Calibration Service for Voltage Transformers and High-voltage Capacitors PDF Author: William Eugene Anderson
Publisher:
ISBN:
Category : Capacitors
Languages : en
Pages : 44

Get Book Here

Book Description


A Calibration Service for Voltage Transformers and High-voltage Capacitors

A Calibration Service for Voltage Transformers and High-voltage Capacitors PDF Author: William E. Anderson
Publisher:
ISBN:
Category :
Languages : en
Pages : 30

Get Book Here

Book Description


The Calibration of DC Voltage Standards at Nist (Classic Reprint)

The Calibration of DC Voltage Standards at Nist (Classic Reprint) PDF Author: B. F. Field
Publisher: Forgotten Books
ISBN: 9780483977839
Category : Technology & Engineering
Languages : en
Pages : 20

Get Book Here

Book Description
Excerpt from The Calibration of DC Voltage Standards at Nist Solid-state voltage standards are calibrated at nist using a specially designed measurement sys tem (denoted It employs a potentiometric method allowing voltage measurements to be made without loading the standard. (an earlier version of this system is described in reference The system is a fully-automated scaling device for com paring arbitrary voltage standards to -v stan dard cells. A three step procedure is used to make a measurement of an unknown voltage: 1) the sys tem is self-calibrated using a group of standard cells of known emf, 2) the unknown solid-state standards are compared to the calibrated system, and 3) the system is self-calibrated again to make sure that no significant drifts in the system have occurred. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

NBS Measurement Services

NBS Measurement Services PDF Author: William E. Anderson
Publisher:
ISBN:
Category : Capacitors
Languages : en
Pages : 30

Get Book Here

Book Description


The Design and Operation of a High Voltage Calibration Facility (Classic Reprint)

The Design and Operation of a High Voltage Calibration Facility (Classic Reprint) PDF Author: Winston W. Scott Jr.
Publisher: Forgotten Books
ISBN: 9780364959114
Category : Technology & Engineering
Languages : en
Pages : 36

Get Book Here

Book Description
Excerpt from The Design and Operation of a High Voltage Calibration Facility The high-voltage calibration facility, in operation for seven years at the National Bureau of Standards Radio Standards Laboratory (rsl) but now at nbs Washington, is described With emphasis on several novel construction features and calibration techniques. The more usual calibration techniques are also outlined for the assistance of those personnel in standards laboratories as signed the task of calibrating With high accuracy, electrostatic volt meters, resistive dividers, and potential transformers at high voltage. Precautions, based on experience in the calibration and use of high voltage standards, are given so that certain errors may be avoided by the users. Key Words: alternating-current, calibration, direct-current, high-voltage, ratio, safety, standards enclosure, transformer, voltage-divider, voltmeter. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

The Nist Digitally Synthesized Power Calibration Source (Classic Reprint)

The Nist Digitally Synthesized Power Calibration Source (Classic Reprint) PDF Author: Nile M. Oldham
Publisher: Forgotten Books
ISBN: 9780265891308
Category :
Languages : en
Pages : 74

Get Book Here

Book Description
Excerpt from The Nist Digitally Synthesized Power Calibration Source Complete circuit diagram of the transconductance amplifier. Complete circuit diagram of the switch box. Basic relationships-oi various routines in the met_6 program. Residual voltage and current integral nonlinearity after gain corrections. Voltage and current differential nonlinearity around 120 V and 5 A. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

NIST Special Publication

NIST Special Publication PDF Author:
Publisher:
ISBN:
Category : Weights and measures
Languages : en
Pages : 1044

Get Book Here

Book Description


The Current Comparator

The Current Comparator PDF Author: W. J. M. Moore
Publisher: IET
ISBN: 9780863411120
Category : Technology & Engineering
Languages : en
Pages : 142

Get Book Here

Book Description
In 1961, Moore and Miljanic in collaboration with N. L Kusters developed the current comparator, for which a patent was granted in 1964. Since that time they and their associates have applied this technique toward advancing the art of electrical measurement. The current comparator comprises a special configuration of concentric toroidal magnetic cores and windings which enable the physical realisation of a very precise ampere-turns ratio standard. It provides the basis for the precise measurement of various electrical quantities at both direct and alternating currents using current ratio techniques. Applications include the calibration of instrument transformers, measurement of the losses of high voltage capacitors and inductive reactors, measurement of the short circuit losses of large power transformers, the calibration of power and energy meters, an alternating current impedance bridge, direct current resistance measurements, the calibration of high direct current metering systems and shunts, a seven decade direct current potentiometer, and a 20 bit digital-to-analogue converter. The book presents the basic theory of the current comparator, methods of construction leading to high ratio accuracies, and the operating principles of the various applications.

High Voltage Divider and Resistor Calibrations (Classic Reprint)

High Voltage Divider and Resistor Calibrations (Classic Reprint) PDF Author: Martin Misakian
Publisher: Forgotten Books
ISBN: 9781390509649
Category :
Languages : en
Pages : 40

Get Book Here

Book Description
Excerpt from High Voltage Divider and Resistor Calibrations High dc voltages frequently are measured with resistive voltage dividers. The dividers typically have one or two low-voltage connections with corresponding ratios. This report describes a calibration service at nbs for high-voltage dividers and resistors that are of sufficient accuracy to be regarded as transfer standards. Devices calibrated at nbs are normally used as standards in industrial and government laboratories. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.