Use of Ligand-modified Micellar-enhanced Ultrafiltration to Slectively Separate Copper Ions from Wastewater Streams

Use of Ligand-modified Micellar-enhanced Ultrafiltration to Slectively Separate Copper Ions from Wastewater Streams PDF Author: Susan Bakhtiari Shadizadeh
Publisher:
ISBN:
Category : Sewage
Languages : en
Pages : 128

Get Book Here

Book Description

Use of Ligand-modified Micellar-enhanced Ultrafiltration to Slectively Separate Copper Ions from Wastewater Streams

Use of Ligand-modified Micellar-enhanced Ultrafiltration to Slectively Separate Copper Ions from Wastewater Streams PDF Author: Susan Bakhtiari Shadizadeh
Publisher:
ISBN:
Category : Sewage
Languages : en
Pages : 128

Get Book Here

Book Description


Use of Ligand-modified Micellar-enhanced Ultrafiltration to Selectively Separate Copper Ions from Wastewater Streams

Use of Ligand-modified Micellar-enhanced Ultrafiltration to Selectively Separate Copper Ions from Wastewater Streams PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The selective removal of target ions from an aqueous solution containing ions of like charge by ligand-modified micellar-enhanced ultrafiltration (LM-MEUF), is presented. In LM-MEUF, surfactant and specially tailored ligand are added to the contaminated stream. The surfactant forms aggregates called micelles, the hydrocarbon core of which the ligand complexed with the target species will solubilize. The surfactant is chosen to have the same charge type as the target ion; therefore, other ions (with similar charge) will not associate with the micelle, which makes the separation of the target ion selective. The solution is then processed by ultrafiltration, using a membrane with pore size small enough to block the passage of the micelles. In this study the divalent copper is the target ion in the solution containing divalent calcium. The surfactant is cetylpyridinium chloride (CPC) and the ligand is 4-hexadecyloxybenzyliminodiacetic acid (C[sub 16]BIDA). Experiments were conducted with batch stirred cells and the results have been compared to separation that take place under a variety of conditions in the LM-MEUF process. Rejections of copper of up to 99.8% are observed, with almost no rejection of calcium, showing that LM-MEUF has excellent selectivity and separation efficiency.

Masters Theses in the Pure and Applied Sciences

Masters Theses in the Pure and Applied Sciences PDF Author: Wade H. Shafer
Publisher: Springer Science & Business Media
ISBN: 1461524539
Category : Science
Languages : en
Pages : 391

Get Book Here

Book Description
Masters Theses in the Pure and Applied Sciences was first conceived, published, and disseminated by the Center for Information and Numerical Data Analysis and Synthesis (CINDAS)* at Purdue University in 1957, starting its coverage of theses with the academic year 1955. Beginning with Volume 13, the printing and dis semination phases of the activity were transferred to University Microfilms/Xerox of Ann Arbor, Michigan, with the though that such an arrangement would be more beneficial to the academic and general scientific and technical community. After five years of this joint undertaking we had concluded that it was in the interest of all concerned if the printing and distribution of the volumes were handled by an international publishing house to assure improved service and broader dissemi nation. Hence, starting with Volume 18, Masters Theses in the Pure and Applied Sciences has been disseminated on a worldwide basis by Plenum Publishing Corporation of New York, and in the same year the coverage was broadened to include Canadian universities. All back issues can also be ordered from Plenum. We have reported in Volume 37 (thesis year 1992) a total of 12,549 thesis titles from 25 Canadian and 153 United States universities. We are sure that this broader base for these titles reported will greatly enhance the value of this impor tant annual reference work. While Volume 37 reports theses submitted in 1992, on occasion, certain uni versities do report theses submitted in previous years but not reported at the time.

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 464

Get Book Here

Book Description


Use of Micellar-enhanced Ultrafiltration and Ligand-modified Micellar-enhanced Ultrafiltration Processes to Remove Dissolved Metals and Organic Solutes from Aqueous Streams

Use of Micellar-enhanced Ultrafiltration and Ligand-modified Micellar-enhanced Ultrafiltration Processes to Remove Dissolved Metals and Organic Solutes from Aqueous Streams PDF Author: Bita Fillipi
Publisher:
ISBN:
Category : Micelles
Languages : en
Pages : 304

Get Book Here

Book Description


Simultaneous Removal of Benzene and Copper from Water and Wastewater Using Micellar-enhanced Ultrafiltration

Simultaneous Removal of Benzene and Copper from Water and Wastewater Using Micellar-enhanced Ultrafiltration PDF Author: Mohammed Ridha Zaid Ahmed
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
To remove metal ions and/or organic molecules from aqueous solutions is a difficulty commonly encountered in the treatment of contaminated water. Traditional ultrafiltration is usually used to separate the high molecular weight molecules and is ineffective in removing heavy metal ions or organic molecules with small molecular weights. Micellar-enhanced ultrafiltration (MEUF) is an effective technique to remove contaminants that traditional ultrafiltration cannot remove. Micellar-enhanced ultrafiltration makes use of the micellar properties of surfactant solutions to remove dissolved ions and/or organics from aqueous streams. Chemical surfactants have proven effective. However compared to biosurfactants they are toxic and create a secondary problem since part of the surfactant monomers frequently leak through the pores of membrane filters. This study is an attempt to examine the effect of rhamnolipid biosurfactant, JBR 425, on contaminant removal from aqueous solutions. The required quantity of rhamnolipid to remove the copper ions as a heavy metal pollutant and benzene molecules as an organic pollutant separately has been determined for different concentrations of pollutants. This quantity, the molar ratio (MR), was 6.25 to obtain a 100% rejection for the copper ions and 1.33 to obtain the same rejection of benzene molecules. When copper and benzene were mixed, these molar ratios have been either improved as in benzene molar ratio which was decreased from 1.33 to 0.56 or remained the same as in copper molar ratio but in all cases rhamnolipid JBR 425 proved of excellent efficiency in the removal of contaminants and a rejection of 100% has been obtained for copper and benzene either separately or simultaneously which is the objective of this study.

De aarde, onze woonplats

De aarde, onze woonplats PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Masters Theses in the Pure and Applied Sciences

Masters Theses in the Pure and Applied Sciences PDF Author: W. H. Shafer
Publisher: Springer Science & Business Media
ISBN: 9780306447112
Category : Education
Languages : en
Pages : 410

Get Book Here

Book Description
Volume 37 (thesis year 1992) reports a total of 12,549 thesis titles from 25 Canadian and 153 US universities (theses submitted in previous years but only now reported are indicated by the thesis year shown in parenthesis). The organization, like that of past years, consists of thesis titles arrange

Government Reports Announcements & Index

Government Reports Announcements & Index PDF Author:
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 1496

Get Book Here

Book Description


Government Reports Annual Index

Government Reports Annual Index PDF Author:
Publisher:
ISBN:
Category : Government publications
Languages : en
Pages : 1224

Get Book Here

Book Description