An Undulator-based Laser Wakefield Accelerator Electron Beam Diagnostic

An Undulator-based Laser Wakefield Accelerator Electron Beam Diagnostic PDF Author: Michael S. Bakeman
Publisher:
ISBN:
Category : Thesis
Languages : en
Pages : 268

Get Book Here

Book Description
Currently particle accelerators such as the Large Hadron Collider use RF cavities with a maximum field gradient of 50-100 MV/m to accelerate particles over long distances. A new type of plasma based accelerator called a Laser Plasma Accelerator (LPA) is being investigated at the LOASIS group at Lawrence Berkeley National Laboratory which can sustain field gradients of 10-100 GV/m. This new type of accelerator offers the potential to create compact high energy accelerators and light sources. In order to investigate the feasibility of producing a compact light source an undulator-based electron beam diagnostic for use on the LOASIS LPA has been built and calibrated. This diagnostic relies on the principal that the spectral analysis of synchrotron radiation from an undulator can reveal properties of the electron beam such as emittance, energy and energy spread. The effects of electron beam energy spread upon the harmonics of undulator produced synchrotron radiation were derived from the equations of motion of the beam and numerically simulated. The diagnostic consists of quadrupole focusing magnets to collimate the electron beam, a 1.5 m long undulator to produce the synchrotron radiation, and a high resolution high gain XUV spectrometer to analyze the radiation. The undulator was aligned and tuned in order to maximize the flux of synchrotron radiation produced. The spectrometer was calibrated at the Advanced Light Source, with the results showing the ability to measure electron beam energy spreads at resolutions as low as 0.1% rms, a major improvement over conventional magnetic spectrometers. Numerical simulations show the ability to measure energy spreads on realistic LPA produced electron beams as well as the improvements in measurements made with the quadrupole magnets. Experimentally the quadrupoles were shown to stabilize and focus the electron beams at specific energies for their insertion into the undulator, with the eventual hope of producing an all optical Free Electron Laser operating in the XUV and soft x-ray regimes.

An Undulator-based Laser Wakefield Accelerator Electron Beam Diagnostic

An Undulator-based Laser Wakefield Accelerator Electron Beam Diagnostic PDF Author: Michael S. Bakeman
Publisher:
ISBN:
Category : Thesis
Languages : en
Pages : 268

Get Book Here

Book Description
Currently particle accelerators such as the Large Hadron Collider use RF cavities with a maximum field gradient of 50-100 MV/m to accelerate particles over long distances. A new type of plasma based accelerator called a Laser Plasma Accelerator (LPA) is being investigated at the LOASIS group at Lawrence Berkeley National Laboratory which can sustain field gradients of 10-100 GV/m. This new type of accelerator offers the potential to create compact high energy accelerators and light sources. In order to investigate the feasibility of producing a compact light source an undulator-based electron beam diagnostic for use on the LOASIS LPA has been built and calibrated. This diagnostic relies on the principal that the spectral analysis of synchrotron radiation from an undulator can reveal properties of the electron beam such as emittance, energy and energy spread. The effects of electron beam energy spread upon the harmonics of undulator produced synchrotron radiation were derived from the equations of motion of the beam and numerically simulated. The diagnostic consists of quadrupole focusing magnets to collimate the electron beam, a 1.5 m long undulator to produce the synchrotron radiation, and a high resolution high gain XUV spectrometer to analyze the radiation. The undulator was aligned and tuned in order to maximize the flux of synchrotron radiation produced. The spectrometer was calibrated at the Advanced Light Source, with the results showing the ability to measure electron beam energy spreads at resolutions as low as 0.1% rms, a major improvement over conventional magnetic spectrometers. Numerical simulations show the ability to measure energy spreads on realistic LPA produced electron beams as well as the improvements in measurements made with the quadrupole magnets. Experimentally the quadrupoles were shown to stabilize and focus the electron beams at specific energies for their insertion into the undulator, with the eventual hope of producing an all optical Free Electron Laser operating in the XUV and soft x-ray regimes.

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC.

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
To couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

Undulator-Based Laser Wakefield Accelerator Electron Beam Energy Spread and Emittance Diagnostic

Undulator-Based Laser Wakefield Accelerator Electron Beam Energy Spread and Emittance Diagnostic PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The design and current status of experiments to couple the Tapered Hybrid Undulator (THUNDER) to the Lawrence Berkeley National Laboratory (LBNL) laser plasma accelerator (LPA) to measure electron beam energy spread and emittance are presented.

Electron-beam Diagnostics for a Laser-driven Plasma Wakefield Accelerator in the Framework of FLASHForward

Electron-beam Diagnostics for a Laser-driven Plasma Wakefield Accelerator in the Framework of FLASHForward PDF Author: Jan-Patrick Schwinkendorf
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Electro-optic Techniques in Electron Beam Diagnostics

Electro-optic Techniques in Electron Beam Diagnostics PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

Modern Diagnostic X-Ray Sources

Modern Diagnostic X-Ray Sources PDF Author: Rolf Behling
Publisher: CRC Press
ISBN: 1000376133
Category : Technology & Engineering
Languages : en
Pages : 413

Get Book Here

Book Description
Gives an up-to-date summary of X-ray source design for applications in modern diagnostic medical imaging. Lays a sound groundwork for education and advanced training in the physics of X-ray production and X-ray interactions with matter. Includes a historical overview of X-ray tube and generator development, including key achievements leading up to the current technological and economic state of the field.

Plasma Channel Guided Laser Wakefield Accelerator

Plasma Channel Guided Laser Wakefield Accelerator PDF Author: Cameron Guy Robinson Geddes
Publisher:
ISBN:
Category :
Languages : en
Pages : 436

Get Book Here

Book Description


Diagnosis of High Energy Electron Beams Produced by Laser Wakefield Accelerators

Diagnosis of High Energy Electron Beams Produced by Laser Wakefield Accelerators PDF Author: Christopher Dominic Murphy
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


The Theory and Design of a Chirped-pulse Inverse Free-electron Laser

The Theory and Design of a Chirped-pulse Inverse Free-electron Laser PDF Author: Anthony Lawrence Troha
Publisher:
ISBN:
Category :
Languages : en
Pages : 762

Get Book Here

Book Description


Ultrafast Phenomena XVI

Ultrafast Phenomena XVI PDF Author: Paul Corkum
Publisher: Springer Science & Business Media
ISBN: 3540959467
Category : Science
Languages : en
Pages : 1031

Get Book Here

Book Description
Ultrafast Phenomena XVI presents the latest advances in ultrafast science, including both ultrafast optical technology and the study of ultrafast phenomena. It covers picosecond, femtosecond and attosecond processes relevant to applications in physics, chemistry, biology, and engineering. Ultrafast technology has a profound impact in a wide range of applications, amongst them biomedical imaging, chemical dynamics, frequency standards, material processing, and ultrahigh speed communications. This book summarizes the results presented at the 16th International Conference on Ultrafast Phenomena and provides an up-to-date view of this important and rapidly advancing field.