Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Main report

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Main report PDF Author:
Publisher:
ISBN:
Category : Boiling water reactors
Languages : en
Pages : 328

Get Book Here

Book Description

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Main report

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Main report PDF Author:
Publisher:
ISBN:
Category : Boiling water reactors
Languages : en
Pages : 328

Get Book Here

Book Description


Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Main Report

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Main Report PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWe.

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Volume 1. Main Report. Technical Report, September 1977-October 1979

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Volume 1. Main Report. Technical Report, September 1977-October 1979 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWE.

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station PDF Author: G. J. Konzek
Publisher:
ISBN: 9780160289958
Category : Boiling water reactors
Languages : en
Pages :

Get Book Here

Book Description


Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Volume 2. Appendices. Technical Report, September 1977-October 1979

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station. Volume 2. Appendices. Technical Report, September 1977-October 1979 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWE. This volume contains the appendices.

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 71

Get Book Here

Book Description
This study presents the results of a comparison of a previous decommissioning cost study by Pacific Northwest Laboratory (PNL) and a recent decommissioning cost study of TLG Engineering, Inc., for the same commercial nuclear power reactor station. The purpose of this comparative analysis on the same plant is to determine the reasons why subsequent estimates for similar plants by others were significantly higher in cost and external occupational radiation exposure (ORE) than the PNL study. The primary purpose of the original study by PNL (NUREG/CR-0672) was to provide information on the available technology, the safety considerations, and the probable costs and ORE for the decommissioning of a large boiling water reactor (BWR) power station at the end of its operating life. This information was intended for use as background data and bases in the modification of existing regulations and in the development of new regulations pertaining to decommissioning activities. It was also intended for use by utilities in planning for the decommissioning of their nuclear power stations. The TLG study, initiated in 1987 and completed in 1989, was for the same plant, Washington Public Supply System's Unit 2 (WNP-2), that PNL used as its reference plant in its 1980 decommissioning study. Areas of agreement and disagreement are identified, and reasons for the areas of disagreement are discussed. 31 refs., 3 figs., 22 tabs.

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station, Addendum 3

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station, Addendum 3 PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Appendices

Technology, Safety, and Costs of Decommissioning a Reference Boiling Water Reactor Power Station: Appendices PDF Author:
Publisher:
ISBN:
Category : Boiling water reactors
Languages : en
Pages :

Get Book Here

Book Description


Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station

Technology, Safety and Costs of Decommissioning a Reference Boiling Water Reactor Power Station PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Preparation of the final Decommissioning Rule by the Nuclear Regulatory Commission (NRC) staff has been assisted by Pacific Northwest Laboratory (PNL) staff familiar with decommissioning matters. These efforts have included updating previous cost estimates developed during the series of studies of conceptually decommissioning reference licensed nuclear facilities for inclusion in the Final Generic Environmental Impact Statement (FGEIS) on decommissioning; documenting the cost updates; evaluating the cost and dose impacts of post-TMI-2 backfits on decommissioning; developing a revised scaling formula for estimating decommissioning costs for reactor plants different in size from the reference boiling water reactor (BWR) described in the earlier study; and defining a formula for adjusting current cost estimates to reflect future escalation in labor, materials, and waste disposal costs. This report presents the results of recent PNL studies to provide supporting information in three areas concerning decommissioning of the reference BWR: updating the previous cost estimates to January 1986 dollars; assessing the cost and dose impacts of post-TMI-2 backfits; and developing a scaling formula for plants different in size than the reference plant and an escalation formula for adjusting current cost estimates for future escalation.

Technology, Safety and Costs of Decommissioning a Reference Pressurized Water Reactor Power Station

Technology, Safety and Costs of Decommissioning a Reference Pressurized Water Reactor Power Station PDF Author: Richard I. Smith
Publisher:
ISBN:
Category : Nuclear reactors
Languages : en
Pages : 180

Get Book Here

Book Description