Seismic Retrofit of Deficient Reinforced Concrete Shear Walls

Seismic Retrofit of Deficient Reinforced Concrete Shear Walls PDF Author: Hamed Layssi
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
"This research describes an experimental and analytical investigation to evaluate the seismic performance of poorly designed and detailed reinforced concrete (RC) flexural shear walls both in their as-built conditions and after being retrofitted. Older shear walls have several deficiencies which make them vulnerable in case of moderate to severe earthquakes. Full-scale shear wall specimens were constructed and tested under reversed cyclic loading. Two different techniques were chosen to retrofit the deficient walls in order to improve the overall performance. A retrofit technique using Carbon Fibre Reinforced Polymer (CFRP), having minimum intervention, was studied to determine the seismic performance. A more labour-intensive repair technique, including the addition of a reinforced concrete jacket in the critical region (location of potential plastic hinging and lap splices of vertical bars) together with CFRP wrapping was also studied. The responses obtained from experiments were used to develop behavioural models, capable of representing the global responses of the walls, as well as critical failure modes observed in the experiments. These models provide useful tools for predicting the complete reversed cyclic loading responses of shear walls. The analytical models were used to predict the responses of a deficient prototype wall-frame structure in its original condition as well as after retrofit, subjected to different seismic hazard levels. This study enabled an evaluation of the performance of the prototype structure to determine the effectiveness of retrofit and repair measures." --

Seismic Retrofit of Deficient Reinforced Concrete Shear Walls

Seismic Retrofit of Deficient Reinforced Concrete Shear Walls PDF Author: Hamed Layssi
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
"This research describes an experimental and analytical investigation to evaluate the seismic performance of poorly designed and detailed reinforced concrete (RC) flexural shear walls both in their as-built conditions and after being retrofitted. Older shear walls have several deficiencies which make them vulnerable in case of moderate to severe earthquakes. Full-scale shear wall specimens were constructed and tested under reversed cyclic loading. Two different techniques were chosen to retrofit the deficient walls in order to improve the overall performance. A retrofit technique using Carbon Fibre Reinforced Polymer (CFRP), having minimum intervention, was studied to determine the seismic performance. A more labour-intensive repair technique, including the addition of a reinforced concrete jacket in the critical region (location of potential plastic hinging and lap splices of vertical bars) together with CFRP wrapping was also studied. The responses obtained from experiments were used to develop behavioural models, capable of representing the global responses of the walls, as well as critical failure modes observed in the experiments. These models provide useful tools for predicting the complete reversed cyclic loading responses of shear walls. The analytical models were used to predict the responses of a deficient prototype wall-frame structure in its original condition as well as after retrofit, subjected to different seismic hazard levels. This study enabled an evaluation of the performance of the prototype structure to determine the effectiveness of retrofit and repair measures." --

Seismic Retrofit of Deficient Reinforced Concrete Shear Walls Using Fibre-Reinforced Polymer Sheets

Seismic Retrofit of Deficient Reinforced Concrete Shear Walls Using Fibre-Reinforced Polymer Sheets PDF Author: Joshua Edward Woods
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Seismic Retrofit and Strengthening of Deficient Reinforced Concrete Shear Walls Using Externally Bonded Fibre Reinforced Polymer Sheets

Seismic Retrofit and Strengthening of Deficient Reinforced Concrete Shear Walls Using Externally Bonded Fibre Reinforced Polymer Sheets PDF Author: Ibrahim Khalil Shaheen
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Techniques for the Seismic Rehabilitation of Existing Buildings

Techniques for the Seismic Rehabilitation of Existing Buildings PDF Author:
Publisher: FEMA
ISBN:
Category : Buildings
Languages : en
Pages : 572

Get Book Here

Book Description


Guidelines for Seismic Retrofit of Existing Buildings

Guidelines for Seismic Retrofit of Existing Buildings PDF Author:
Publisher:
ISBN:
Category : Juvenile Nonfiction
Languages : en
Pages : 74

Get Book Here

Book Description
This renamed version of the former Uniform code for building conservation guidelines for retrofitting unreinforced masonry bearing wall buildings, reinforced concrete and reinforced masonry buildings, wood frame residential buildings, and concrete with masonry infill buildings.

Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications

Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 9782883940758
Category : Technology & Engineering
Languages : en
Pages : 234

Get Book Here

Book Description
fib Bulletin 35 is the first bulletin to publish documentation from an fib short course. These courses are held worldwide and cover advanced knowledge of structural concrete in general, or specific topics. They are organized by fib and given by internationally recognized experts in fib, often supplemented with local experts active in fib. They are based on the knowledge and expertise from fib's ten Commissions and nearly fifty Task Groups. fib Bulletin 35 presents the course materials developed for the short course "Retrofitting of Concrete Structures through Externally Bonded FRP, with emphasis on Seismic Applications", given in Ankara and Istanbul in June 2005. The course drew on expertise both from outside Turkey and from the large pool of local experts on this subject. In most countries of the world, the building stock is ageing and needs continuous maintenance or repair. Moreover, the majority of existing constructions are deficient in the light of current knowledge and design codes. The problem of structural deficiency of existing constructions is especially acute in seismic regions, as, even there, seismic design of structures is relatively recent. The direct and indirect costs of demolition and reconstruction of structurally deficient constructions are often prohibitive; furthermore they entail a substantial waste of natural resources and energy. Therefore, structural retrofitting is becoming increasingly widespread throughout the world. Externally bonded Fibre Reinforced Polymers (FRPs) are rapidly becoming the technique of choice for structural retrofitting. They are cleaner and easier to apply than conventional retrofitting techniques, reduce disruption to the occupancy and operation of the facility, do not generate debris or waste, and reduce health and accident hazards at the construction site as well as noise and air pollution in the surroundings. fib Bulletin 35 gives state-of-the-art coverage of retrofitting through FRPs and presents relevant provisions from three recent standardisation milestones: EN 1998-3:2005 "Eurocode 8: Design of structures for earthquake resistance - Part 3: Assessment and retrofitting of buildings", the 2005 Draft of the Turkish seismic design code, and the Italian regulatory document CNR-DT 200/04, "Instructions for Design, Execution and Control of Strengthening Interventions by Means of Fibre-Reinforced Composites" (2004).

Seismic Retrofit of Reinforced Concrete Shear Walls Using Fibre Reinforced Polymer Composites

Seismic Retrofit of Reinforced Concrete Shear Walls Using Fibre Reinforced Polymer Composites PDF Author: Hossam El-Sokkary
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description


Seismic Assessment and Retrofit of Reinforced Concrete Buildings

Seismic Assessment and Retrofit of Reinforced Concrete Buildings PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 9782883940642
Category : Technology & Engineering
Languages : en
Pages : 322

Get Book Here

Book Description
In most parts of the developed world, the building stock and the civil infrastructure are ageing and in constant need of maintenance, repair and upgrading. Moreover, in the light of our current knowledge and of modern codes, the majority of buildings stock and other types of structures in many parts of the world are substandard and deficient. This is especially so in earthquake-prone regions, as, even there, seismic design of structures is relatively recent. In those regions the major part of the seismic threat to human life and property comes from old buildings. Due to the infrastructure's increasing decay, frequently combined with the need for structural upgrading to meet more stringent design requirements (especially against seismic loads), structural retrofitting is becoming more and more important and receives today considerable emphasis throughout the world. In response to this need, a major part of the fib Model Code 2005, currently under development, is being devoted to structural conservation and maintenance. More importantly, in recognition of the importance of the seismic threat arising from existing substandard buildings, the first standards for structural upgrading to be promoted by the international engineering community and by regulatory authorities alike are for seismic rehabilitation of buildings. This is the case, for example, of Part 3: Strengthening and Repair of Buildings of Eurocode 8 (i. e. of the draft European Standard for earthquake-resistant design), and which is the only one among the current (2003) set of 58 Eurocodes attempting to address the problem of structural upgrading. It is also the case of the recent (2001) ASCE draft standard on Seismic evaluation of existing buildings and of the 1996 Law for promotion of seismic strengthening of existing reinforced concrete structures in Japan. As noted in Chapter 1 of this Bulletin, fib - as CEB and FIP did before - has placed considerable emphasis on assessment and rehabilitation of existing structures. The present Bulletin is a culmination of this effort in the special but very important field of seismic assessment and rehabilitation. It has been elaborated over a period of 4 years by Task Group 7.1 Assessment and retrofit of existing structures of fib Commission 7 Seismic design, a truly international team of experts, representing the expertise and experience of all the important seismic regions of the world. In the course of its work the team had six plenary two-day meetings: in January 1999 in Pavia, Italy; in August 1999 in Raleigh, North Carolina; in February 2000 in Queenstown, New Zealand; in July 2000 in Patras, Greece; in March 2001 in Lausanne, Switzerland; and in August 2001 in Seattle, Washington. In October 2002 the final draft of the Bulletin was presented to public during the 1st fib Congress in Osaka. It was also there that it was approved by fib Commission 7 Seismic Design. The contents is structured into main chapters as follows: 1 Introduction - 2 Performance objectives and system considerations - 3 Review of seismic assessment procedures - 4 Strength and deformation capacity of non-seismically detailed components - 5 Seismic retrofitting techniques - 6 Probabilistic concepts and methods - 7 Case studies

Seismic Retrofit of Reinforced Concrete Shear Walls

Seismic Retrofit of Reinforced Concrete Shear Walls PDF Author: James Paterson
Publisher:
ISBN:
Category :
Languages : en
Pages : 246

Get Book Here

Book Description
"The four shear wall specimens were tested under reversed cyclic loading. Two of these walls had a lap splice in the longitudinal steel at the base of the wall and the other two had a lap splice 600 mm from the base of the wall. One of each of these specimens was tested in the 'as-built' condition and the other two were retrofit prior to testing. The test results show that the retrofit strategies were successful in improving the ductility and energy dissipation of the shear walls." --

Handbook on Seismic Retrofit of Buildings

Handbook on Seismic Retrofit of Buildings PDF Author: Amarnath Chakrabarti
Publisher: Alpha Science International, Limited
ISBN:
Category : Science
Languages : en
Pages : 488

Get Book Here

Book Description
The Handbook on Seismic Retrofit of Buildings is a compiled source of technical information for engineers and professionals in the buildings industry, decision making officials and students. The Handbook is divided into 17 chapters, covering - basic concepts of earthquakes, seismic design and retrofit of buildings, seismic vulnerability assessment, retrofit strategies for different types of buildings, geotechnical and foundation aspects, advanced applications, quality assurance and case studies.