Performance of the CDF Silicon VerteX Detector

Performance of the CDF Silicon VerteX Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Get Book Here

Book Description
The current status of the online and offline performance of the CDF Silicon VerteX detector is presented. So far, at low radiation dose, the device delivers good quality data. After the latest alignment using collision data, a spatial resolution of 13 pm is achieved in the transverse plane, demonstrating that CDF has a powerful tool to detect b decay vertices.

Performance of the CDF Silicon VerteX Detector

Performance of the CDF Silicon VerteX Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 5

Get Book Here

Book Description
The current status of the online and offline performance of the CDF Silicon VerteX detector is presented. So far, at low radiation dose, the device delivers good quality data. After the latest alignment using collision data, a spatial resolution of 13 pm is achieved in the transverse plane, demonstrating that CDF has a powerful tool to detect b decay vertices.

Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector

Operational Experience, Improvements, and Performance of the CDF Run II Silicon Vertex Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 29

Get Book Here

Book Description


Operation of the CDF Silicon Vertex Detector with Colliding Beams at Fermilab

Operation of the CDF Silicon Vertex Detector with Colliding Beams at Fermilab PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Get Book Here

Book Description
In this paper we briefly describe the main features of the CDF Silicon Vertex Detector (SVX) and discuss its performance during actual colliding beam operation at the Fermilab Tevatron. Details on S/N ratio, alignment, resolution and efficiency are given.

Operation and Performance of the Silicon Vertex Detector (SVX)̀ at CDF.

Operation and Performance of the Silicon Vertex Detector (SVX)̀ at CDF. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Get Book Here

Book Description
The authors describe the operation and performance of the Silicon Vertex Detector (SVX)̀, which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX ̀include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb−1 of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12?m. This provides a powerful tool to do top and bottom physics.

Operation and Performance of the Silicon Vertex Detector (SVX') at CDF.

Operation and Performance of the Silicon Vertex Detector (SVX') at CDF. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The authors describe the operation and performance of the Silicon Vertex Detector (SVX'), which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX' include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb[sup -1] of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12 [mu]m. This provides a powerful tool to do top and bottom physics.

Performance of the CDF Online Silicon Vertex Tracker

Performance of the CDF Online Silicon Vertex Tracker PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The Online Silicon Vertex Tracker (SVT) is the new trigger processor dedicated to the 2-D reconstruction of charged particle trajectories at the Level 2 of the CDF trigger. The SVT links the digitized pulse heights found within the Silicon Vertex detector to the tracks reconstructed in the Central Outer Tracker by the Level 1 fast track finder. Preliminary tests of the system took place during the October 2000 commissioning run of the Tevatron Collider. During the April-October 2001 data taking it was possible to evaluate the performance of the system. In this paper we review the tracking algorithms implemented in the SVT and we report on the performance achieved during the early phase of run II.

The CDF Silicon Vertex Detector

The CDF Silicon Vertex Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 21

Get Book Here

Book Description
A silicon strip vertex detector was designed, constructed and commissioned at the CDF experiment at the Tevatron collider at Fermilab. The mechanical design of the detector, its cooling and monitoring are presented. The front end electronics employing a custom VLSI chip, the readout electronics and various components of the SVX system are described. The system performance and the experience with the operation of the detector in the radiation environment are discussed. The device has been taking colliding beams data since May of 1992, performing at its best design specifications and enhancing the physics program of CDF.

System Software Design for the CDF Silicon Vertex Detector

System Software Design for the CDF Silicon Vertex Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 6

Get Book Here

Book Description
An automated system for testing and performance evaluation of the CDF Silicon Vertex Detector (SVX) data acquisition electronics is described. The SVX data acquisition chain includes the Fastbus Sequencer and the Rabbit Crate Controller and Digitizers. The Sequencer is a programmable device for which we developed a high level assembly language. Diagnostic, calibration and data acquisition programs have been developed. A distributed software package was developed in order to operate the modules. The package includes programs written in assembly and Fortran languages that are executed concurrently on the SVX Sequencer modules and either a microvax or an SSP. Test software was included to assist technical personnel during the production and maintenance of the modules. Details of the design of different components of the package are reported.

The CDF Silicon Vertex Detector for Run II.

The CDF Silicon Vertex Detector for Run II. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The 8 layer, 720k channel CDF Run II silicon detector is an essential part of the heavy flavor tagging and forward tracking capabilities of the CDF experiment. A summary of the experience in commissioning and operating this double-sided detector during the first 2 years of Run II is presented. The performances of the silicon in term of resolution, efficiency are also described. The results of the studies of radiation damage and the expected operational limits are discussed. A short description of the SVT, the Level 2 Silicon Vertex Trigger, one of the major upgrades related to the new silicon device is also presented. Finally, some of the many physics results achieved by means of the new Silicon+SVT machinery are also reviewed.

Status and Performance of the CDF Run 2 Silicon Detectors

Status and Performance of the CDF Run 2 Silicon Detectors PDF Author: Jason Nielsen
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
In 2001, an upgraded silicon detector system was installed in the CDF II experiment on the Tevatron at Fermilab. The complete system consists of three silicon micro-strip detectors: SVX II with five layers for precision tracking, Layer 00 with one beampipe-mounted layer for vertexing, and two Intermediate Silicon Layers located between SVX II and the main CDF II tracking chamber. Currently all detectors in the system are operating at or near design levels. The performance of the combined silicon system is excellent in the context of CDF tracking algorithms, and the first useful physics results from the innermost Layer 00 detector have been recently documented. Operational and monitoring efforts have also been strengthened to maintain silicon efficiency through the end of Run 2 at the Tevatron.