Optical Methods of Measuring Plasma Jet Temperatures PDF Download
Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Optical Methods of Measuring Plasma Jet Temperatures PDF full book. Access full book title Optical Methods of Measuring Plasma Jet Temperatures by Hoyt Clarke Hottel. Download full books in PDF and EPUB format.
Author: Hoyt Clarke Hottel
Publisher:
ISBN:
Category : High temperatures
Languages : en
Pages : 84
Get Book
Book Description
Author: Hoyt Clarke Hottel
Publisher:
ISBN:
Category : High temperatures
Languages : en
Pages : 84
Get Book
Book Description
Author: Hoyt Clarke Hottel
Publisher:
ISBN:
Category : High temperatures
Languages : en
Pages : 0
Get Book
Book Description
A literature study was made of methods for measuring temperatures of hot gases and plasmas, with emphasis on evaluation of non-spectroscopic techniques. For application to measurements on air stabilized plasma jets at temperatures to 8000 K and in the pressure range from 0.01 to 10 atmospheres, an optical technique was chosen, modified for fast response by use of a multiplier phototube as the receiver. The technique involves display on a cathode ray oscilloscope of signals alternately representing a single path and a double path (by means of a mirror) of the image of a portion of the plasma jet, the alternation being at 13. Extension of the range of possible temperature measurement to as high as 10,000 K is possible by interposition between the target and the pyrometer filament of neutral density glass filters, each having a transmissivity of about 4.5%. (Author).
Author: Hoyt Clarke Hottel
Publisher:
ISBN:
Category : Plasma (Ionized gases)
Languages : en
Pages : 88
Get Book
Book Description
A literature study was made of methods for measuring temperatures of hot gases and plasmas, with emphasis on evaluation of non-spectroscopic techniques. For application to measurements on air stabilized plasma jets at temperatures to 8000 K and in the pressure range from 0.01 to 10 atmospheres, an optical technique was chosen, modified for fast response by use of a multiplier phototube as the receiver. The technique involves display on a cathode ray oscilloscope of signals alternately representing a single path and a double path (by means of a mirror) of the image of a portion of the plasma jet, the alternation being at 13. Extension of the range of possible temperature measurement to as high as 10,000 K is possible by interposition between the target and the pyrometer filament of neutral density glass filters, each having a transmissivity of about 4.5%. (Author).
Author: H. C. HOTTEL
Publisher:
ISBN:
Category :
Languages : en
Pages : 1
Get Book
Book Description
The application of two-path optical pyrometry to measurement of plasma jet temperature was studied from both theoretical and practical aspects. A pyrometer was constructed with its detection system consisting of a selected 1P21 photomultiplier associated with an electronic filter tuned to 1 c. Comparison between the unknown source and a calibrated filament is made at this frequency which is chosen to give optimum signal-to-noise ratio. The transparency of high temperature plasma necessitates the use of an opacifier if the two-path technique is to be employed with any accuracy. The use of sodium as a non-grey temperature indicating probe was investigated. The measurememt of integral radiancy is made almost monochromatic by passage through a narrow cut interference filter centered on 5892 angstroms, having a halfwidth of 7.5 angstroms. This enables the sodium D line doublet to be selected uniquely but renders the Beer's law expression inapplicable unless the shape of the emission line is known. The theories of spectral line broadening suggested the use of a theory by Lindholm to give this data and it was applied to the interpretation of the pyrometer readings. (Author).
Author: H. C. Hottel
Publisher:
ISBN:
Category :
Languages : en
Pages : 72
Get Book
Book Description
A photoelectric pyrometer has been designed and used to measure the temperature of a one atmosphere argon plasma jet over the range 4000K - 8500K. The jet which was virtually transparent normally was partially opacified with sodium, a non-gray temperature probe, and temperature measurements were based on the application of a non-gray/gray brightness matching theory to a modified two-path optical temperature measuring technique. The pyrometer was designed to detect uniquely the spectral radiation from the added sodium and to match the brightness of this radiation with that of gray radiation, from a calibrated filament. The brightnesses were matched at one cycle-second and observed over the narrow waveband (8A) of an interference filter centered on the D-line doublet of sodium (5890/5896A). The measured temperatures agree to within 1.6% of the enthalpy temperatures calculated from an energy balance over the whole system. (Author).
Author: United States. National Aeronautics and Space Administration
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 1318
Get Book
Book Description
Author: United States. Wright Air Development Division
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 1050
Get Book
Book Description
Author: United States. National Bureau of Standards
Publisher:
ISBN:
Category : Temperature measurements
Languages : en
Pages : 144
Get Book
Book Description
Author: Defense Documentation Center (U.S.)
Publisher:
ISBN:
Category : Science
Languages : en
Pages : 824
Get Book
Book Description
Author: Lief O. Olsen
Publisher:
ISBN:
Category : Temperature measurements
Languages : en
Pages : 56
Get Book
Book Description