Mass Spectrometer Measurements of the Positive Ion Composition in the D- and E-regions of the Ionosphere

Mass Spectrometer Measurements of the Positive Ion Composition in the D- and E-regions of the Ionosphere PDF Author: P.A. Zbinden
Publisher:
ISBN:
Category :
Languages : en
Pages : 22

Get Book Here

Book Description

Mass Spectrometer Measurements of the Positive Ion Composition in the D- and E-regions of the Ionosphere

Mass Spectrometer Measurements of the Positive Ion Composition in the D- and E-regions of the Ionosphere PDF Author: P.A. Zbinden
Publisher:
ISBN:
Category :
Languages : en
Pages : 22

Get Book Here

Book Description


Positive Ion Composition Measurements in the Lower Ionosphere During the 12 November 1966 Solar Eclipse

Positive Ion Composition Measurements in the Lower Ionosphere During the 12 November 1966 Solar Eclipse PDF Author: Rocco S. Narcisi
Publisher:
ISBN:
Category : Cations
Languages : en
Pages : 22

Get Book Here

Book Description
Positive ion composition measurements in the D and E regions were performed on three rocket flights during the 1966 solar eclipse program conducted at Cassino, Brazil. The E region results showed that, at totality, NO+ and O2+ decreased in density while the ratio NO+/O2 increased. Long-lived meteoric ions appeared to be unaffected during the short period of the eclipse. A submerged layer of meteoric ions became prominent at totality when the molecular ion densities were smallest and produced a sporadic E layer. The D region results indicated that the decay in the water cluster ions at totality was probably less than a factor of four in the vicinity of 80 km. This work represents part of a continuing Air Force program to study lower ionospheric processes which affect communications. (Author).

Ion Composition Measurements and Related Ionospheric Processes in the D and Lower E Regions

Ion Composition Measurements and Related Ionospheric Processes in the D and Lower E Regions PDF Author: R. S. Narcisi
Publisher:
ISBN:
Category : D region
Languages : en
Pages : 16

Get Book Here

Book Description


Mass Spectrometry in the D-region Ionosphere

Mass Spectrometry in the D-region Ionosphere PDF Author: R. S. Narcisi
Publisher:
ISBN:
Category : D region
Languages : en
Pages : 62

Get Book Here

Book Description


Mass Spectrometric Measurements of Positive Ions at Altitudes from 64 to 112 Kilometers

Mass Spectrometric Measurements of Positive Ions at Altitudes from 64 to 112 Kilometers PDF Author: R. S. Narcisi
Publisher:
ISBN:
Category : Cations
Languages : en
Pages : 24

Get Book Here

Book Description


Mass Spectrometry in the D-region Ionosphere

Mass Spectrometry in the D-region Ionosphere PDF Author: R. S. NARCISI
Publisher:
ISBN:
Category : D region
Languages : en
Pages : 0

Get Book Here

Book Description
A quadrupole mass spectrometer system employing a liquid nitrogen chilled zeolite pump has recently been developed for sampling positive ions at altitudes above 50 kilometers. This system was flown successfully on a Nike-Cajun rocket on 31 October 1963, and has provided the first positive ion composition measurements in the D-region. For simultaneous environmental measurements of ion and electron densities, two spherical electrostatic analyzers were included in the rocket payload. Supplemental information on ionospheric conditions was provided by a ground-based ionosonde. Due to the high sensitivity of the system approximately twenty (20) positive ion peaks were detected in the mass range 10 to 45 amu within the altitude range of 64 to 112 km. The predominant ions detected within the D-region (64 to 82 km) were 18(+), 30(+) and (37=1)(+), with 32(+) rapidly rising above 75 km approaching the abundance of 30(+) at 83 km. At 82.5 km a sharp transition occurred in the spectra, characterized by the rapid disappearance of 18(+) and 37(+) and instantaneous appearance of six (6) new ion peaks. Five (5) of these ion peaks are suggested to be the metallic ions of sodium (23(+)), magnesium (24(+), 25(+), 26(+)) and calcium (40(+)). The metallic ions all exhibited an identical altitude profile, a ten (10) km-wide peak with a maximum at 95 km, a minimum at 105 km, and then continuously increasing until apogee at 112 km.

Mass Spectrometric Measurements of Positive Ions at Altitudes from 64 to 112 Kilometers

Mass Spectrometric Measurements of Positive Ions at Altitudes from 64 to 112 Kilometers PDF Author: R. S. Narcisi
Publisher:
ISBN:
Category : Cations
Languages : en
Pages : 26

Get Book Here

Book Description


Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement

Development of an Ion Mass Spectrometer and Sounding Rocket System for D-region Cluster-ion Measurement PDF Author: A. Bailey
Publisher:
ISBN:
Category : Complex ions
Languages : en
Pages : 108

Get Book Here

Book Description
An Ion Mass Spectrometer and supporting Sounding Rocket System were developed to make in situ measurements of cluster-ions in the D-region of the ionosphere. A cryogenically vacuum-pumped quadrupole mass filter and secondary emission ion counter are coupled to make mass spectral measurements of positive and negative ion composition in ambient gas sampled at the apex of a cone designed to attach the shock wave induced by supersonic sounding rocket speeds. (Author).

Ion Composition Measurements of the Disturbed and Quiet D-region in 1980-1981

Ion Composition Measurements of the Disturbed and Quiet D-region in 1980-1981 PDF Author: William Swider
Publisher:
ISBN:
Category : Ionosphere
Languages : en
Pages : 32

Get Book Here

Book Description
Mass-spectrometric data were obtained from rocket-borne instruments flown from Poker Flat, Alaska, during October 1980 and 1981 under disturbed and quiet conditions, respectively. The positive ion spectra for both events appear to be compatible with our current understanding of the D-region. The instrument configuration (cone front) yielded poor negative ion currents. Much more work is needed to develop a D-region mass spectrometer which accurately observes in-situ negative ions. This need is underscored by the fact that only light negative ions, possibly mostly contaminants, were present near 80 km. Ions two to three times heavier were obtained in earlier flights with a blunt front end configuration. Nitric oxide profiles derived for both cases were within the range expected. The 1980 flight, under disturbed conditions, yielded higher concentrations than did the 1981 flight. Keywords include: D-region; Ionosphere; and Mesosphere.

Ion Composition Measurements of the Disturbed and Quiet D-region in 1980-1981

Ion Composition Measurements of the Disturbed and Quiet D-region in 1980-1981 PDF Author:
Publisher:
ISBN:
Category : Ionosphere
Languages : en
Pages : 0

Get Book Here

Book Description
Mass-spectrometric data were obtained from rocket-borne instruments flown from Poker Flat, Alaska, during October 1980 and 1981 under disturbed and quiet conditions, respectively. The positive ion spectra for both events appear to be compatible with our current understanding of the D-region. The instrument configuration (cone front) yielded poor negative ion currents. Much more work is needed to develop a D-region mass spectrometer which accurately observes in-situ negative ions. This need is underscored by the fact that only light negative ions, possibly mostly contaminants, were present near 80 km. Ions two to three times heavier were obtained in earlier flights with a blunt front end configuration. Nitric oxide profiles derived for both cases were within the range expected. The 1980 flight, under disturbed conditions, yielded higher concentrations than did the 1981 flight. Keywords include: D-region; Ionosphere; and Mesosphere.