Evaluation of the LASL Automated Spectrophotometer for Uranium Determination at Submilligram Levels

Evaluation of the LASL Automated Spectrophotometer for Uranium Determination at Submilligram Levels PDF Author: R. M. Hollen
Publisher:
ISBN:
Category : Actinide elements
Languages : en
Pages : 8

Get Book Here

Book Description
The LASL automated spectrophotometer, designed for determination of 1 to 14 mg of uranium and 0.5 to 14 mg of plutonium, has been evaluated for determination of lower levels of uranium to 0.12 mg. The essentially linear response of absorbance is maintained and the standard deviation for a single measurement is constant at about 0.013 mg of uranium, corresponding to a maximum uncertainty of about 10 percent at the 0.12-mg limit. The instrument was applied to the analysis of a series of low-level-concentration, 0.07- to 0.8-mg/ml uranium samples. The results were not statistically different from those obtained by a manual spectrophotometric method.

Evaluation of the LASL Automated Spectrophotometer for Uranium Determination at Submilligram Levels

Evaluation of the LASL Automated Spectrophotometer for Uranium Determination at Submilligram Levels PDF Author: R. M. Hollen
Publisher:
ISBN:
Category : Actinide elements
Languages : en
Pages : 8

Get Book Here

Book Description
The LASL automated spectrophotometer, designed for determination of 1 to 14 mg of uranium and 0.5 to 14 mg of plutonium, has been evaluated for determination of lower levels of uranium to 0.12 mg. The essentially linear response of absorbance is maintained and the standard deviation for a single measurement is constant at about 0.013 mg of uranium, corresponding to a maximum uncertainty of about 10 percent at the 0.12-mg limit. The instrument was applied to the analysis of a series of low-level-concentration, 0.07- to 0.8-mg/ml uranium samples. The results were not statistically different from those obtained by a manual spectrophotometric method.

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 1780

Get Book Here

Book Description


Publications of LASL Research

Publications of LASL Research PDF Author: Los Alamos Scientific Laboratory
Publisher:
ISBN:
Category : Research
Languages : en
Pages : 200

Get Book Here

Book Description


Publications of Los Alamos Research

Publications of Los Alamos Research PDF Author: Los Alamos National Laboratory
Publisher:
ISBN:
Category : Research
Languages : en
Pages : 348

Get Book Here

Book Description


Automated Spectrophotometer for Plutonium and Uranium Determination

Automated Spectrophotometer for Plutonium and Uranium Determination PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The automated spectrophotometer described is the first in a planned series of automated instruments for determining plutonium and uranium in nuclear fuel cycle materials. It has a throughput rate of 5 min per sample and uses a highly specific method of analysis for these elements. The range of plutonium and uranium measured is 0.5 to 14 mg and 1 to 14 mg, respectively, in 0.5 ml or less of solution with an option to pre-evaporate larger volumes. The precision of the measurements is about 0.02 mg standard deviation over the range corresponding to about 2 rel percent at the 1-mg level and 0.2 rel percent at the 10-mg level. The method of analysis involves the extraction of tetrapropylammonium plutonyl and uranyl trinitrate complexes into 2-nitropropane and the measurement of the optical absorbances in the organic phase at unique peak wavelengths. Various aspects of the chemistry associated with the method are presented. The automated spectrophotometer features a turntable that rotates as many as 24 samples in tubes to a series of stations for the sequential chemical operations of reagent addition and phase mixing to effect extraction, and then to a station for the absorbance measurement. With this system, the complications of sample transfers and flow-through cells are avoided. The absorbance measurement system features highly stable interference filters and a microcomputer that controls the timing sequence and operation of the system components. Output is a paper tape printout of three numbers: a four-digit number proportional to the quantity of plutonium or uranium, a two-digit number that designates the position of the tube in the turntable, and a one-digit number that designates whether plutonium or uranium was determined. Details of the mechanical and electrical components of the instrument and of the hardware and software aspects of the computerized control system are provided.

Handbook of Nuclear Safeguards Measurement Methods

Handbook of Nuclear Safeguards Measurement Methods PDF Author: Donald R. Rogers
Publisher:
ISBN:
Category : Materials management
Languages : en
Pages : 760

Get Book Here

Book Description


Automated Spectrophotometer for Plutonium and Uranium Determination

Automated Spectrophotometer for Plutonium and Uranium Determination PDF Author: D. D. Jackson
Publisher:
ISBN:
Category :
Languages : en
Pages : 76

Get Book Here

Book Description


INIS Atomindex

INIS Atomindex PDF Author:
Publisher:
ISBN:
Category : Nuclear energy
Languages : en
Pages : 1184

Get Book Here

Book Description


Government reports annual index

Government reports annual index PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 1190

Get Book Here

Book Description


An Automatic-inline Spectrophotometer for the Determination of Uranium in the Presence of Aluminum Nitrate, Nitric Acid and Highly Radioactive Fission Products

An Automatic-inline Spectrophotometer for the Determination of Uranium in the Presence of Aluminum Nitrate, Nitric Acid and Highly Radioactive Fission Products PDF Author: Robert Birney Kimball
Publisher:
ISBN:
Category : Spectrophotometer
Languages : en
Pages : 62

Get Book Here