ETUDE THEORIQUE ET EXPERIMENTALE DU TRANSFERT DE CHALEUR EN REGIME PERIODIQUE POUR UN ECOULEMENT FORCE A PLAN DIRECTEUR

ETUDE THEORIQUE ET EXPERIMENTALE DU TRANSFERT DE CHALEUR EN REGIME PERIODIQUE POUR UN ECOULEMENT FORCE A PLAN DIRECTEUR PDF Author: KACEM.. MANSOURI
Publisher:
ISBN:
Category :
Languages : fr
Pages : 195

Get Book Here

Book Description
CE TRAVAIL A POUR OBJET L'ANALYSE DU COUPLAGE CONDUCTION-CONVECTION FORCEE EN REGIME THERMIQUE VARIABLE, DANS LE CAS D'UN ECOULEMENT FLUIDE ENTRE PLAQUES PARALLELES EPAISSES. IL S'AGIT DE PRECISER LA FONCTION DE TRANSFERT OBTENUE POUR UNE EXCITATION PERIODIQUE IMPOSEE A L'ENTREE DU FLUIDE. L'ETUDE COMPREND TROIS PARTIES: LA PREMIERE EST CONSACREE A L'ANALYSE THEORIQUE DANS LE CAS D'UN ECOULEMENT LAMINAIRE A PLAN DIRECTEUR. LE COUPLAGE EST TRAITE EN ECRIVANT L'EGALITE DES FLUX ET DES TEMPERATURES A L'INTERFACE (CONDITION LIMITE DITE DE TYPE 4). UNE SOLUTION ANALYTIQUE A ETE DEVELOPPEE MOYENNANT L'HYPOTHESE D'UN PROFIL DE VITESSE UNIFORME (SLUG FLOW). CE PROBLEME EST EGALEMENT RESOLU A L'AIDE DU MODELE QUASI-STATIONNAIRE, LE COUPLAGE A L'INTERFACE EST ALORS ASSURE EN INTRODUISANT LA NOTION DE COEFFICIENT DE CONVECTION. LA DEUXIEME PARTIE CONCERNE LA SIMULATION NUMERIQUE D'UN ECOULEMENT FLUIDE EN REGIME LAMINAIRE ENTRE DEUX PLAQUES PARALLELES. LE CHAMP DYNAMIQUE EST CONSIDERE ETABLI PARABOLIQUE. LA REPONSE THERMIQUE EST ETUDIEE EN FONCTION DES DIFFERENTS PARAMETRES DU PROBLEME, TELS QUE LA FREQUENCE DU SIGNAL D'ENTREE ET LES CARACTERISTIQUES THERMOPHYSIQUES DU FLUIDE ET DU SOLIDE. LE MODELE NUMERIQUE UTILISANT UNE FORMULATION EXPLICITE AUX DIFFERENCES FINIES EST VALIDE PAR RAPPORT A LA SOLUTION EXACTE DEVELOPPEE DANS LA PREMIERE PARTIE. EN REGIME TURBULENT, DES PROFILS CLASSIQUES DE DISTRIBUTION DE VITESSE ET DE VISCOSITE SONT UTILISES DANS UN MODELE PSEUDO-LAMINAIRE. LES RESULTATS SONT ALORS COMPARES A CEUX OBTENUS SIMPLEMENT PAR L'UTILISATION DU NOMBRE DE NUSSELT. LA TROISIEME PARTIE EST RELATIVE A L'ETUDE EXPERIMENTALE D'UN ECOULEMENT D'EAU DANS UN CANAL RECTANGULAIRE DE SECTION 300 X 20 MM#2 ET DE LONGUEUR 3 M. LES PAROIS SONT EN ACIER INOXYDABLE DE 5 MM D'EPAISSEUR. LE FLUIDE ABORDE LE CANAL AINSI DEFINI AVEC UNE TEMPERATURE D'ENTREE EVOLUANT SELON UNE LOI TEMPORELLE PERIODIQUE. ON S'INTERESSE A LA DISTRIBUTION DE TEMPERATURE LONGITUDINALE DANS L'AXE DU CANAL ET A LA PAROI. EN PRATIQUE, NOUS DISPOSONS DE DEUX PARAMETRES, A SAVOIR LE NOMBRE DE REYNOLDS ET LA FREQUENCE DU SIGNAL D'ENTREE. LES RESULTATS EXPERIMENTAUX SONT CONFRONTES AUX MODELES PRECEDENTS