Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level-split-core current transformers (CTs) and power monitoring meters-have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces. NREL evaluated Meazon's single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level-split-core current transformers (CTs) and power monitoring meters-have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces. NREL evaluated Meazon's single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

Case Study: Laboratory and Field Evaluation of Circuit-Level Electrical Submetering with Integrated Metering System

Case Study: Laboratory and Field Evaluation of Circuit-Level Electrical Submetering with Integrated Metering System PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
Laboratory and field demonstration of circuit-level electrical submetering technology. Report provides a background of the technology and how it works, outlines the testing methodology and presents results on measurement accuracy and ability of the technology to be rapidly integrated into both electrical panels/infrastructure and into an analytics platform. Cost effectiveness results are discussed for the specific field demonstration site.

Submetering of Building Energy and Water Usage

Submetering of Building Energy and Water Usage PDF Author: John P. Holdren
Publisher:
ISBN: 9781437962314
Category :
Languages : en
Pages : 74

Get Book Here

Book Description


CAD/CAM Abstracts

CAD/CAM Abstracts PDF Author:
Publisher:
ISBN:
Category : CAD/CAM systems
Languages : en
Pages : 616

Get Book Here

Book Description


Energy Information Abstracts

Energy Information Abstracts PDF Author:
Publisher:
ISBN:
Category : Power (Mechanics)
Languages : en
Pages : 858

Get Book Here

Book Description


Trade Cases

Trade Cases PDF Author: Commerce Clearing House
Publisher:
ISBN:
Category : Competition, Unfair
Languages : en
Pages : 1528

Get Book Here

Book Description


UbiComp 2007: Ubiquitous Computing

UbiComp 2007: Ubiquitous Computing PDF Author: John Krumm
Publisher: Springer Science & Business Media
ISBN: 3540748539
Category : Computers
Languages : en
Pages : 537

Get Book Here

Book Description
This book constitutes the refereed proceedings of the 9th International Conference on Ubiquitous Computing, UbiComp 2007. It covers all current issues in ubiquitous, pervasive and handheld computing systems and their applications, including tools and techniques for designing, implementing, and evaluating ubiquitous computing systems; mobile, wireless, and ad hoc networking infrastructures for ubiquitous computing; privacy, security, and trust in ubiquitous and pervasive systems.

Building Performance Evaluation

Building Performance Evaluation PDF Author: Wolfgang F.E. Preiser
Publisher: Springer
ISBN: 3319568620
Category : Technology & Engineering
Languages : en
Pages : 320

Get Book Here

Book Description
The main aim of this book is to present an intriguing retrospective of Building Performance Evaluation (BPE) as it evolved from Post-Occupancy Evaluation (POE) over the past 25 years. On one hand, this is done by updating original authors' chapter content of Building Evaluation, the first edition published in 1989. That, in turn, is augmented by an orientation toward current and future practice on the other, including new authors who are engaged in ongoing, cutting edge projects. Therefore, individual, methodology oriented chapters covering the fundamental principles of POE and BPE go along with major thematic chapters, topics of which like sustainability or integration of new technologies are addressed in a diversity of case studies from around the globe. Research, methodologies, and framework of POEs continue to evolve. POEs are one step, on the larger scale of BPE, in understanding how buildings function after they are occupied. This resource helps a rchitects, building owners, and facility managers understand the implications and reactions to the facilities that they designed, built and/or commissioned. By considering the whole process from conception to future uses of the building, there can be a more holistic approach to the planning, programming, design, construction, occupancy, and future adaptability of the structure. This book is dedicated to first editor Wolfgang F. E. Preiser who passed away during the process of editing and reviewing chapters of this volume.

Net Zero Energy Buildings

Net Zero Energy Buildings PDF Author: Linda Reeder
Publisher: Routledge
ISBN: 1317289994
Category : Technology & Engineering
Languages : en
Pages : 283

Get Book Here

Book Description
This book presents 18 in-depth case studies of net zero energy buildings—low-energy building that generate as much energy as they consume over the course of a year—for a range of project types, sizes, and U.S. climate zones. Each case study describes the owner’s goals, the design and construction process, design strategies, measurement and verification activities and results, and project costs. With a year or more of post-occupancy performance data and other project information, as well as lessons learned by project owners and developers, architects, engineers, energy modelers, constructors, and operators, each case study answers the questions: What were the challenges to achieving net zero energy performance, and how were these challenges overcome? How would stakeholders address these issues on future projects? Are the occupants satisfied with the building? Do they find it comfortable? Is it easy to operate? How can other projects benefit from the lessons learned on each project? What would the owners, designers, and constructors do differently knowing what they know now? A final chapter aggregates processes to engage in and pitfalls to avoid when approaching the challenges peculiar to designing, constructing, and owning a net zero energy building. By providing a wealth of comparable information, this book which will flatten the learning curve for designing, constructing, and owning this emerging building type and improve the effectiveness of architectural design and construction.

Lighting Waste Disposal

Lighting Waste Disposal PDF Author:
Publisher:
ISBN:
Category : Ballasts (Electricity)
Languages : en
Pages : 18

Get Book Here

Book Description