A Study to Determine the Feasibility of Using Class A Foam for Structural Firefighting at Dallas/Fort Worth International Airport

A Study to Determine the Feasibility of Using Class A Foam for Structural Firefighting at Dallas/Fort Worth International Airport PDF Author: Alan D. Black
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Get Book Here

Book Description
Training recommendations were also made that would require approximately four to five hours of comprehensive training in order to develop firefighter confidence in the agent as well as some experience with pump and application procedures.

A Study to Determine the Feasibility of Using Class A Foam for Structural Firefighting at Dallas/Fort Worth International Airport

A Study to Determine the Feasibility of Using Class A Foam for Structural Firefighting at Dallas/Fort Worth International Airport PDF Author: Alan D. Black
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Get Book Here

Book Description
Training recommendations were also made that would require approximately four to five hours of comprehensive training in order to develop firefighter confidence in the agent as well as some experience with pump and application procedures.

A Feasibility Study in the Use of Class A Foam for Structural Firefighting in the Stamford Fire Department

A Feasibility Study in the Use of Class A Foam for Structural Firefighting in the Stamford Fire Department PDF Author: Kevin B. Tappe
Publisher:
ISBN:
Category :
Languages : en
Pages : 14

Get Book Here

Book Description
During the past few years, the Stamford Fire Department has been grappling with the idea of using Class A foam for structural firefighting. This research is based on the question of whether the Stamford Fire Department should adapt it's equipment and procedures to include the use of Class A foam for structural firefighting in Stamford, Connecticut.

Class a Foam for Structural Firefighting

Class a Foam for Structural Firefighting PDF Author: U. S. Department of Homeland Security
Publisher: CreateSpace
ISBN: 9781482675993
Category :
Languages : en
Pages : 60

Get Book Here

Book Description
This report provides a general overview of nozzle-aspirated class A and compressed air foam systems. It then discusses hands-on evaluations by several fire departments that are currently using class A foam systems in structural fire suppression or wildland/urban interface fire protection. Reported advantages and disadvantages in the use of class A foams and CAFS in structural firefighting, both from field experience and from recent fire protection literature, are included in this report.

Class A Foam for Structural Firefighting

Class A Foam for Structural Firefighting PDF Author:
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 62

Get Book Here

Book Description


Determining the Feasibility of Compressed Air Foam for Structural Firefighting

Determining the Feasibility of Compressed Air Foam for Structural Firefighting PDF Author: Lynn Washburn-Livingston
Publisher:
ISBN:
Category :
Languages : en
Pages : 107

Get Book Here

Book Description
and live fire tests to evaluate the performance of compressed air foam as compared to water. The results of the research indicated that CAFS can provide efficient operations with effective extinguishment and enhanced personnel safety. The results also revealed there are disadvantages of CAFS that must be addressed. Based on the research results, six recommendations were made to address integration and implementation of CAFS on the Davenport Fire Department.

Compressed Air Foam for Structural Fire Fighting: A Field Test; Boston, Massachusetts

Compressed Air Foam for Structural Fire Fighting: A Field Test; Boston, Massachusetts PDF Author:
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 29

Get Book Here

Book Description


Class "A" Firefighting Foam and Its Applicable Use in Structural Firefighting by the Wheeling Fire Department

Class Author: Keith S. MacIsaac
Publisher:
ISBN:
Category :
Languages : en
Pages : 47

Get Book Here

Book Description
It was found that the amount of water necessary to provide initial fire suppression was an average of 29.5 percent less with the use of Class "A" foam versus plain water. In total overall operations, including salvage and overhaul, the overall necessary water usage was reduced by 37.4 percent. Based upon the information obtained and the results of the experiment, several recommendations are made.

Class A Foam for Structural Firefighting

Class A Foam for Structural Firefighting PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 55

Get Book Here

Book Description


Class "A" Foams in Structural Fire Service Applications: a Comparison Study of Foam Versus Water

Class Author: Michael Sturgeon
Publisher:
ISBN:
Category :
Languages : en
Pages : 42

Get Book Here

Book Description
Interested departments should conduct their own studies and provide a report of the results to members of the fire service.

Foam Over Air Inflatable Structure Feasibility Study

Foam Over Air Inflatable Structure Feasibility Study PDF Author: Alvin Smith
Publisher:
ISBN:
Category :
Languages : en
Pages : 70

Get Book Here

Book Description
A study has been conducted to determine the feasibility and practicality of using dual- wall air inflatable sections as forms upon which can be constructed and fabricated a rigid foam shell that will be self- supporting and capable of withstanding cer- tain conditions of environmental stress such as wind and snow loading. The study also provided for the acquisition and com- pilation of data regarding equipment, tools, materials, mold releases, protective coatings and structural design. These data were compiled from laboratory studies, literature from industry, personal interviews and practical experience in applying rigid foams in various situations. (Author-PL).