Polymer-duct systems for internal bonded post-tensioning

Polymer-duct systems for internal bonded post-tensioning PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 2883941157
Category : Technology & Engineering
Languages : en
Pages : 183

Get Book Here

Book Description
The purpose of this recommendation - fib Bulletin 75: Polymer-duct systems for internal bonded post-tensioning - is to update and amend fib Bulletin 7:Corrugated plastic ducts for internal bonded post-tensioning, a technical report published in 2000. fib Bulletin 75 is meant as a cornerstone for the technical approval of polymer (plastic) ducts for internal bonded post-tensioning and possibly for the test procedures of a future testing standard. The updated bulletin includes new information on the design and detailing of concrete structures containing tendons with polymer ducts. The recommendation provides detailed test specifications for polymer materials, duct components and duct systems. In addition, the report contains recommendations for approval testing and attestations of conformity for polymer-duct systems. Although the new generation of corrugated polymer ducts for bonded post-tensioning have now been around for approximately twenty years, products still differ in material properties, geometrical detail, installation procedures and on-site use. Unlike corrugated steel ducts or smooth polyethylene (PE) pipes, they have not yet become standardized. It is the opinion of fib Task Group 9.16 and Commission 9 that these plastic ducts should, therefore, still be subjected to a systems approval process. This recommendation offers information acquired from twenty years of experience as well as new specifications that will, hopefully, lead to the standardization of polymer-duct systems.

Polymer-duct systems for internal bonded post-tensioning

Polymer-duct systems for internal bonded post-tensioning PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 2883941157
Category : Technology & Engineering
Languages : en
Pages : 183

Get Book Here

Book Description
The purpose of this recommendation - fib Bulletin 75: Polymer-duct systems for internal bonded post-tensioning - is to update and amend fib Bulletin 7:Corrugated plastic ducts for internal bonded post-tensioning, a technical report published in 2000. fib Bulletin 75 is meant as a cornerstone for the technical approval of polymer (plastic) ducts for internal bonded post-tensioning and possibly for the test procedures of a future testing standard. The updated bulletin includes new information on the design and detailing of concrete structures containing tendons with polymer ducts. The recommendation provides detailed test specifications for polymer materials, duct components and duct systems. In addition, the report contains recommendations for approval testing and attestations of conformity for polymer-duct systems. Although the new generation of corrugated polymer ducts for bonded post-tensioning have now been around for approximately twenty years, products still differ in material properties, geometrical detail, installation procedures and on-site use. Unlike corrugated steel ducts or smooth polyethylene (PE) pipes, they have not yet become standardized. It is the opinion of fib Task Group 9.16 and Commission 9 that these plastic ducts should, therefore, still be subjected to a systems approval process. This recommendation offers information acquired from twenty years of experience as well as new specifications that will, hopefully, lead to the standardization of polymer-duct systems.

Acceptance of post-tensioning systems for cryogenic applications

Acceptance of post-tensioning systems for cryogenic applications PDF Author: FIB – International Federation for Structural Concrete
Publisher: FIB - International Federation for Structural Concrete
ISBN: 2883941475
Category : Technology & Engineering
Languages : en
Pages : 116

Get Book Here

Book Description
Since the Second World War the demand of energy has undergone an exponential growth that has led to a sharp annual increase in the use of natural gas in both, cities and thermal power stations. Nowadays, the strategic relevance of natural gas as a main source of energy is evident with a contribution of more than 20% of the total world consumption. This development in increasing demand of natural gas has led for a need of suitable storage and transportation infrastructure. Various gases, especially hydrocarbons, are preferably stored in liquid form for transportation and storage since the phase transformation from gas to liquid comes with a significant reduction of the volume (e.g. up to 600 times). Gases can be liquefied by raising the pressure or by cooling to their boiling point, which for most gases is below 0°C. This is known as cryogenic storage. The term cryogenic is derived from two Greek words, namely kryos meaning icy-cold and genes which can be translated as shape. These fib recommendations are concerned about post-tensioning systems used in cryogenic tanks and have been formulated on the basis of actual available knowledge with the aim to reflect the current state of the art. Consequently, these recommendations have included a classification of the different cryogenic tanks typologies used in the past and nowadays, the associated different tendon types depending on their exposure to low temperature (e.g. never, only accidentally or during normal tank operation) and the testing regime required for acceptance of the materials and the post-tensioning system according to this document. An international working group comprising more than 20 experts from administrative authorities, universities, laboratories, owners, structural designers, suppliers of prestressing steels and post-tensioning systems suppliers have actively contributed in order to develop these recommendations. This text has been written to cover best construction practices around the world, and to provide material specifications which are considered to be the most advanced available at the time of preparing this text. For ease of use (for Owner, Designer and Post-tensioning System Supplier), the content has been arranged systematically according to the system components into chapters focusing on performance characteristics, requirements and acceptance criteria.

Precast segmental bridges

Precast segmental bridges PDF Author: fib Fédération internationale du béton
Publisher: FIB - Féd. Int. du Béton
ISBN: 288394122X
Category : Technology & Engineering
Languages : en
Pages : 198

Get Book Here

Book Description
The concept of precast segmental bridges is not new: the first application documented was from the mid-1940s, designed by Eugene Freyssinet and built over the river Marne near Luzancy in France, between 1944 and 1946. Although innovative, it also contained traditional wet concrete joints between the members. The impressive breakthrough came slightly later with the introduction of match-cast joints by Jean Muller, first for a bridge near Buffalo (USA) in 1952, and later for a bridge across the River Seine at Choisy le Roi near Paris in 1962. This opened the way for a large number of new developments in terms of design, production approaches and construction techniques, and precast prestressed concrete segmental construction became rapidly one of the most efficient and successful bridge construction methods all over the world. These developments are still evolving, but the interaction between design, production and construction is a critical factor for success: the interaction creates opportunities to optimise the scheme, but at the same time is crucial to ensure safety, especially during construction, when large weights are moved, placed and secured, frequently at substantial heights. Engineers of all disciplines involved should interact during the development and realisation of precast segmental bridge (PSB) schemes, to conclude the optimum method statement and consequently check all the intermediate steps of the method statement in terms of stress, stiffness, stability, production and constructability. With the ongoing development of the PSB concept, and consequently moving limits in terms of dimensions, it was concluded to be appropriate to develop a Guide to good practice for the PSB construction method. The present report was developed by an integrated team of engineers with roots in design, structural engineering, production and construction, and provides a valuable source of knowledge, experience, recommendations and examples, with particular emphasis on the fib Model Code for Concrete Structures 2010 and fib Bulletins 20, 33, 48 and 75. I would like to thank all the members of Task Group 1.7, all the individual contributors from outside Task Group 1.7, and the reviewers of the Technical Council of the fib for their contribution to this Guide to good practice. In particular, I would like to thank Gopal Srinivasan and Marcos Sanchez, who, apart from their own contributions, did the final editorial work for this bulletin.

2022 fib Awards for Outstanding Concrete Structures

2022 fib Awards for Outstanding Concrete Structures PDF Author: FIB – International Federation for Structural Concrete
Publisher: FIB - International Federation for Structural Concrete
ISBN: 2883941599
Category : Technology & Engineering
Languages : en
Pages : 48

Get Book Here

Book Description
The fib has two major missions now. One is to work toward the publication of the Model Code 2020, and the other is to respond to the global movement toward carbon neutrality. While the former is steadily progressing toward completion, the latter will require significant efforts for generations to come. As we all know, cement, the primary material for concrete, is a sector that accounts for 8.5% of the world’s CO2 emissions. And the structural concrete that fib handles consume 60% of that. In other words, we need to know the reality that our structural concrete is emitting 5% of the world’s CO2. From now on, fib members, suppliers, designers, builders, owner’s engineers, and academic researchers will be asked how to solve this difficult problem. In general, most of the CO2 emissions in the life cycle of structural concrete come from the production stage of materials and the use stage after construction, i.e. A1 to A3 and B1 to B5 processes as defined in EN15978. Cement and steel sectors, which are the main materials for structural concrete, are expected to take various measures to achieve zero carbon in their respective sectors by 2050. Until then, we must deal with the transition with our low carbon technologies. Regarding the production stage, the fib has recently launched TG4.8 “Low carbon concrete”. And the latest low carbon technologies will be discussed there. On the other hand, in the use stage, there is very little data on the relationship between durability and intervention and maintenance so far. The data accumulation here is the work of the fib, a group of various experts on structural concrete. Through-life management using highly durable structures and precise monitoring will enable to realize minimum maintenance in the use stage and to minimize CO2 emissions. Furthermore, it is also possible to contribute to the reduction of CO2 emissions in the further stage after the first cycle by responding to the circular economy, that is, deconstruction (C), reuse, and recycle (D). However, the technology in this field is still in its infancy, and further research and development is expected in the future. As described above, structural concrete can be carbon neutral in all aspects of its conception, and it can make a significant contribution when it is realized. The fib will have to address these issues in the future. Of course, it will not be easy, and it will take time. However, if we do not continue our efforts as the only international academic society on structural concrete in the world to achieve carbon neutrality, the significance of our very existence may be questioned. Long before Portland cement was invented, Roman concrete, made of volcanic ash and other materials, was the ultimate low-carbon material, and is still in use 2’000 years later because of its non-reinforced structure and lack of deterioration factors. Reinforced concrete, which made it possible to apply concrete to structures other than arches and domes, is only 150 years old. Prestressed concrete is even younger, with only 80 years of history. Now that we think about it, we realize that Roman concrete, which is non-reinforced low carbon concrete, is one of the examples of problem solving that we are trying to achieve. We have new materials, such as coated reinforcement, FRP, and fiber reinforced concrete, which can be used in any structural form. To overcome this challenge with all our wisdom would be to live up to the feat the Romans accomplished 2’000 years ago. Realizing highly durable and elegant structures with low-carbon concrete is the key to meet the demands of the world in the future. I hope you will enjoy reading this AOS brochure showing the Outstanding Concrete Structures Awards at the fib 2022 Congress in Oslo. And I also hope you will find some clues for the challenges we are facing.

Acceptance of cable systems using prestressing steels

Acceptance of cable systems using prestressing steels PDF Author: FIB – International Federation for Structural Concrete
Publisher: FIB - Féd. Int. du Béton
ISBN: 2883941297
Category : Technology & Engineering
Languages : en
Pages : 126

Get Book Here

Book Description
Cable-stayed structures have become increasingly popular over the last 30 years and have been used in all parts of the world. Modern cable-stayed bridges have a history of over 50-years and have been constructed with span lengths ranging from 15 m to over 1000 m. Many long span cable-stayed bridges have been built for railway and highway traffic applications. Stay cables have also been used on pedestrian structures, many of which are architecturally striking and have become landmark structures. There is growing use in building structures, particularly for cable-supported roofs. Most of the cable supported structures have been in the form of cable-stayed bridges; but in recent years, extradosed bridges have seen increased popularity among the designers. Led by the experience in Japan, more than 200 extradosed bridges have been constructed worldwide in the past 15 years. The first edition of these fib recommendations was published as fib Bulletin 30 in 2005 and was the first specification published by fib for stay cable systems. This new bulletin has been updated based on Bulletin 30 with the aim to reflect the current state of the art and encompass the latest knowledge in cable systems. In addition, it has been the aspiration of Commission 5 and Task Group 5.5 to harmonize the guidance in this updated bulletin with other stay cable recommendations from around the world, including those from Europe, Japan and the USA. This new bulletin is intended to supersede and replace fib Bulletin 30. It is recommended that it be used in lieu of fib Bulletin 30 for all future cable supported applications. The updated bulletin introduces several significant enhancements to the specifications: These recommendations are applicable to both stay cable and extradosed cable applications. In the past, there has been some debate over the boundary between cable-stayed and extradosed bridges. This bulletin presents a new continuous approach valid for both. A completely new testing requirement to assess the performance of cable systems under bending fatigue, including both anchorages and saddles, if applicable, has been added. Testing requirements for saddle systems have been reformulated. In addition to the bending fatigue test noted above, new testing procedures for stay cable saddles with isolated tensile elements are introduced. This includes tests for saddle axial fatigue, friction and tensile testing, and determination of the effective saddle friction coefficient. Expanded system qualification, including requirements for both stay cable and extradosed applications. Includes new provisions for MTE qualification and additional load transferring connection devices. Minimum number of tests is specified for each. A new in-situ damping measurement test has been added to verify the actual damping ratio of the damping devices installed. By testing on site, selected cables may be excited to vibrate without and with the damping devices so that the observed v vibration behaviour can be compared to the specified value. Other revisions have been made to reflect the current state of practice: Expanded quality control testing requirements Inclusion of epoxy-coated prestressing steel as a protection layer. Previous recommendations only considered zinc coatings. Specifications for epoxy coating material are given. Requirements for stainless steel components such as pipes, caps and plates Updated guidance for designing lightning protection systems Detailed recommendations for different levels of inspection of cable systems, including: initial, routine, detailed and exceptional inspections An updated list of references, relevant standards, and extended literature

Towards a rational understanding of shear in beams and slabs

Towards a rational understanding of shear in beams and slabs PDF Author: fib Fédération internationale du béton
Publisher: FIB - Féd. Int. du Béton
ISBN: 2883941254
Category : Technology & Engineering
Languages : en
Pages : 354

Get Book Here

Book Description
Reliable performance of beams and slabs in shear is essential for the safety and also for the serviceability of reinforced concrete structures. A possible failure in shear is usually a brittle failure, which underlines the importance of the correct specification of the load carrying capacity in shear. The knowledge of performance in shear is steadily developing and it is now obvious that older structures were not always designed in accordance with contemporary requirements. The increasing load – mainly on bridges – requires the assessment of existing structures, often followed by their strengthening. An appropriate understanding of actual performance of concrete structures in shear is therefore of primary interest. The workshop which was held in Zürich in 2016 brought together a significant number of outstanding specialists working in the field of shear design, who had a chance to exchange their opinions and proposals for improving the current knowledge of shear behaviour in beams and slabs. The specialists came from different parts of the world, which made the workshop general and representative. The workshop was organised by fib Working Party 2.2.1 “Shear in Beams” (convened by O. Bayrak), which is a part of fib Commission 2 "Analysis and Design". Individual contributions mainly address shear in beams with low transversal reinforcement. It is crucial because many existing structures lack such reinforcement. Different theories, e.g. Critical Shear Crack Theory (CSCT), Modified Compression Field Theory (MCFT), Multi-Action Shear Model (MASM), etc. were presented and compared with procedures used in selected national codes or in the fib Model Code 2010. The models for shear design were often based to a great extent on empirical experience. The refined presented models tend to take into account the physical mechanisms in structures more effectively. A brittle behaviour in shear requires not only to check the equilibrium and failure load, but also to follow the progress of failure, including the crack development and propagation, stress redistribution, etc. The significance of the size effect – which causes the nominal strength of a large structure to be smaller than that of a small structure – was pointed out. Nowadays, the fibre reinforcement is used more than before since it allows significant labour costs savings in the construction industry. The contribution of fibres is suitable for shear transfer. It is very convenient that not only ordinary fibre reinforced elements were addressed but also the UHPFRC beams. The production of this new material is indeed growing, while the development of design recommendations has not been sufficiently fast. Fatigue resistance of structures with low shear reinforcement is also an important issue, which was also addressed in this bulletin. It cannot be neglected in prestressed bridges, which are exposed to dynamic loads. A comprehensive understanding of the shear behaviour is necessary. Although many laboratory experiments are carried out, they are suitable only to a limited extent. New testing methods are being developed and show promising results, e.g. digital image correlation. An actual structure performance should rather be tested on a large scale, ideally on real structures under realistic loading conditions.ii The papers presented in the bulletin are a basis for the discussion in view of the development of updated design rules for the new fib Model Code (MC2020), which is currently under preparation. fib Bulletins like this one, dealing with shear, help to transfer knowledge from research to design practice. The authors are convinced that it will lead to better new structures design of as well as to savings and to a safety increase in older existing structures, whose future is often decided now.

Partial factor methods for existing concrete structures

Partial factor methods for existing concrete structures PDF Author: FIB - Féd. Int. du Béton
Publisher: FIB - Féd. Int. du Béton
ISBN: 2883941203
Category : Technology & Engineering
Languages : en
Pages : 145

Get Book Here

Book Description
For a large part of the existing buildings and infrastructure the design life has been reached or will be reached in the near future. These structures might need to be reassessed in order to investigate whether the safety requirements are met. Current practice on the assessment of existing concrete structures however needs a thorough evaluation from a risk and reliability point of view, as they are mostly verified using simplified procedures based on the partial factor method commonly applied in design of new structures. Such assessments are often conservative and may lead to expensive upgrades. Although the last decades reliability-based assessment of existing concrete structures has gained wide attention in the research field, a consistent reliability-based assessment framework and a practically applicable codified approach which is compatible with the Eurocodes and accessible for common structural engineering problems in everyday practice is currently missing. Such an approach however allows for a more uniform, more objective and probably more widely applied assessment approach for existing concrete structures. Hence, in this bulletin two different partial factor formats are elaborated, i.e. the Design Value Method (DVM) and the Adjusted Partial Factor Method (APFM), enabling the incorporation of specific reliability related aspects for existing structures. The DVM proposes a fundamental basis for evaluating partial factors whereas the APFM provides adjustment factors to be applied on the partial factors for new structures in EN 1990. In this bulletin both methods are elaborated and evaluated and a basis is provided for decision making regarding the target safety level of existing structures.

Precast Insulated Sandwich Panels

Precast Insulated Sandwich Panels PDF Author: fib Fédération internationale du béton
Publisher: FIB - Féd. Int. du Béton
ISBN: 2883941246
Category : Technology & Engineering
Languages : en
Pages : 146

Get Book Here

Book Description
During the mid-20th century, with the rise of industrial prefabrication, precast concrete sandwich panels started being used as cladding for buildings. Since then, society and construction industry have become increasingly aware of energy efficiency in all fields, including affordability and sustainability consciousness, while maintaining the buildings’ durability. As such, buildings have been subject to increasingly stringent requirements which has kept the technology of sandwich panels continually at the forefront of building envelope evolution. Nowadays, sandwich panels have reached the highest standards of functional performance and aesthetic appeal. In building construction, these sandwich panel attributes combine with the well-known advantages of prefabrication including structural efficiency, flexibility in use, speed of construction, quality consciousness, durability, and sustainability. Sandwich panels have gained more exposure, thus representing quite a significant application within the prefabrication industry and a vital component of the precast market. The fib Commission “Prefabrication” is eager to promote the development of all precast structural concrete products and to share the knowledge and experience gained, to aid with practical design and construction. By issuing this comprehensive overview, “Guide to Good Practice”, a better understanding of design considerations, structural analysis, building physics, use of materials, manufacturing methods, equipment usage and field performance will be provided. This document contains the latest information currently available worldwide. The Commission is particularly proud that this document is a result of close cooperation with PCI and that it is published by both the fib and PCI. This cooperation started six years ago, first with comparing the different approaches to several issues, then progressively integrating and producing common documents, like this one, that hasn’t yet been treated in a specific Guide by either body. This Guide is intended to be the reference document to all who are interested in utilising the advantages of Precast Sandwich wall panels. In conjunction with the previously published Planning and Design Handbook on Precast Building Structures, the designer will have significant resources to integrate sandwich wall panels into any applicable structure.

Benchmarking of deemed-to-satisfy provisions in standards

Benchmarking of deemed-to-satisfy provisions in standards PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 2883941165
Category : Technology & Engineering
Languages : en
Pages : 205

Get Book Here

Book Description
Standards for specifying and ensuring the durability of new concrete structures are commonly of the prescriptive kind. fib Bulletin 76: Benchmarking of deemed-to-satisfy provisions in standards - Durability of reinforced concrete structures exposed to chlorides presents the benchmarking of a number of rules for chloride-induced corrosion as given in national codes such as European, US and Australian standards. This new benchmark determines the reliability ranges in the chloride-induced depassivation of rebar if the deemed-to-satisfy rules of different countries are taken into consideration. It does not only involve (probabilistic) calculations using input mainly based on short-term and rapid laboratory-test data but also involves input based on an independent assessment of existing structures. The reliability analyses are carried out using the probabilistic design approach for chloride-induced corrosion presented in fib Bulletin 34: Model Code for Service Life Design (2006), fib Model Code for Concrete Structures 2010 and ISO 16204:2012. The work compares the calculated reliability ranges thus determined with the target reliabilities proposed by current specifications and, based on the comparison, offers a proposal for the improvement of deemed-to-satisfy rules and specifications. fib Bulletin 76 presents and discusses in detail the input data for the examined model parameters and offers an extensive annexe documenting the values of the individual parameters used in the analyses. It thus provides a reliable database for the performance-based probabilistic service-life design of concrete structures exposed to chlorides, be they in the form of salt fog, sea water or de-icing salts.

Punching shear of structural concrete slabs

Punching shear of structural concrete slabs PDF Author: FIB - Féd. Int. du Béton
Publisher: FIB - Féd. Int. du Béton
ISBN: 2883941211
Category : Technology & Engineering
Languages : en
Pages : 396

Get Book Here

Book Description
fib Bulletin 81 reports the latest information available to researchers and practitioners on the analysis, design and experimental evidence of punching shear of structural concrete slabs. It follows previous efforts by the International Federation for Structural Concrete (fib) and its predecessor the Euro-International Committee for Concrete (CEB), through CEB Bulletin 168, Punching Shear in Reinforced Concrete (1985) and fibBulletin 12, Punching of structural concrete slabs (2001), and an international symposium sponsored by the punching shear subcommittee of ACI Committee 445 (Shear and Torsion) and held in Kansas City, Mo., USA, in 2005. This bulletin contains 18 papers that were presented in three sessions as part of an international symposium held in Philadelphia, Pa., USA, on October 25, 2016. The symposium was co-organized by the punching shear sub-committee of ACI 445 and by fib Working Party 2.2.3 (Punching and Shear in Slabs) with the objectives of not only disseminating information on this important design subject but also promoting harmonization among the various design theories and treatment of key aspects of punching shear design. The papers are organized in the same order they were presented in the symposium. The symposium honored Professor Emeritus Neil M. Hawkins (University of Illinois at Urbana-Champaign, USA), whose contributions through the years in the field of punching shear of structural concrete slabs have been paramount. The papers cover key aspects related to punching shear of structural concrete slabs under different loading conditions, the study of size effect on punching capacity of slabs, the effect of slab reinforcement ratio on the response and failure mode of slabs, without and with shear reinforcement, and its implications for the design and formulation in codes of practice, an examination of different analytical tools to predict the punching shear response of slabs, the study of the post-punching response of concrete slabs, the evaluation of design provisions in modern codes based on recent experimental evidence and new punching shear theories, and an overview of the combined efforts undertaken jointly by ACI 445 and fib WP 2.2.3 to generate test result databanks for the evaluation and calibration of punching shear design recommendations in North American and international codes of practice.