Seismic Retrofit of Existing Reinforced Concrete Buildings

Seismic Retrofit of Existing Reinforced Concrete Buildings PDF Author: Stelios Antoniou
Publisher: John Wiley & Sons
ISBN: 1119987342
Category : Technology & Engineering
Languages : en
Pages : 549

Get Book Here

Book Description
Seismic Retrofit of Existing Reinforced Concrete Buildings Understand the complexities and challenges of retrofitting building infrastructure Across the world, buildings are gradually becoming structurally unsound. Many were constructed before seismic load capacity was a mandatory component of building standards, and were often built with low-quality materials or using unsafe construction practices. Many more are simply aging, with materials degrading, and steel corroding. As a result, efforts are ongoing to retrofit existing structures, and to develop new techniques for assessing and enhancing seismic load capacity in order to create a safer building infrastructure worldwide. Seismic Retrofit of Existing Reinforced Concrete Buildings provides a thorough book-length discussion of these techniques and their applications. Balancing theory and practice, the book provides engineers with a broad base of knowledge from which to approach real-world seismic assessments and retrofitting projects. It incorporates knowledge and experience frequently omitted from the building design process for a fuller account of this critical engineering subfield. Seismic Retrofit of Existing Reinforced Concrete Buildings readers will also find: Detailed treatment of each available strengthening technique, complete with advantages and disadvantages In-depth guidelines to select a specific technique for a given building type and/or engineering scenario Step-by-step guidance through the assessment/retrofitting process Seismic Retrofit of Existing Reinforced Concrete Buildings is an ideal reference for civil and structural engineering professionals and advanced students, particularly those working in seismically active areas.

ASCE Standard, ASCE/SEI, 41-17, Seismic Evaluation and Retrofit of Existing Buildings

ASCE Standard, ASCE/SEI, 41-17, Seismic Evaluation and Retrofit of Existing Buildings PDF Author: American Society of Civil Engineers
Publisher:
ISBN: 9780784414859
Category : Buildings
Languages : en
Pages : 550

Get Book Here

Book Description
Standard ASCE/SEI 41-17 describes deficiency-based and systematic procedures that use performance-based principles to evaluate and retrofit existing buildings to withstand the effects of earthquakes.

Strengthening and Retrofitting of Existing Structures

Strengthening and Retrofitting of Existing Structures PDF Author: Aníbal Costa
Publisher: Springer
ISBN: 981105858X
Category : Technology & Engineering
Languages : en
Pages : 339

Get Book Here

Book Description
This book presents the fundamentals of strengthening and retrofitting approaches, solutions and technologies for existing structures. It addresses in detail specific techniques for the strengthening of traditional constructions, reinforced concrete buildings, bridges and their foundations. Finally, it discusses issues related to standards and economic decision support tools for retrofitting.

Computational Methods and Experimental Measurements XIX & Earthquake Resistant Engineering Structures XII

Computational Methods and Experimental Measurements XIX & Earthquake Resistant Engineering Structures XII PDF Author: P. De Wilde
Publisher: WIT Press
ISBN: 1784663336
Category : Mathematics
Languages : en
Pages : 369

Get Book Here

Book Description
A collection of research originating from WIT Conferences on Computational Methods and Earthquake Resistant Engineering Structures. In its 19th year the CMEM conference continues to provide highest quality research which forms part 1 of this book. Part 2 includes leading research as presented at the 12th edition of the ERES conference.

Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings (FEMA 350)

Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings (FEMA 350) PDF Author: Federal Emergency Agency
Publisher: FEMA
ISBN:
Category :
Languages : en
Pages : 11

Get Book Here

Book Description
This report, FEMA-350 - Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings has been developed by the SAC Joint Venture under contract to the Federal Emergency Management Agency (FEMA) to provide organizations engaged in the development of consensus design standards and building code provisions with recommended criteria for the design and construction of new buildings incorporating moment-resisting steel frame construction to resist the effects of earthquakes. It is one of a series of companion publications addressing the issue of the seismic performance of steel moment-frame buildings. The set of companion publications includes: FEMA-350 - Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings. This publication provides recommended criteria, supplemental to FEMA-302 - 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, for the design and construction of steel moment-frame buildings and provides alternative performance-based design criteria. FEMA-351 - Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings. This publication provides recommended methods to evaluate the probable performance of existing steel moment-frame buildings in future earthquakes and to retrofit these buildings for improved performance. FEMA-352 - Recommended Postearthquake Evaluation and Repair Criteria for Welded Steel Moment-Frame Buildings. This publication provides recommendations for performing postearthquake inspections to detect damage in steel moment-frame buildings following an earthquake, evaluating the damaged buildings to determine their safety in the postearthquake environment, and repairing damaged buildings. FEMA-353 - Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications. This publication provides recommended specifications for the fabrication and erection of steel moment frames for seismic applications. The recommended design criteria contained in the other companion documents are based on the material and workmanship standards contained in this document, which also includes discussion of the basis for the quality control and quality assurance criteria contained in the recommended specifications. The information contained in these recommended design criteria, hereinafter referred to as Recommended Criteria, is presented in the form of specific design and performance evaluation procedures together with supporting commentary explaining part of the basis for these recommendations.

Reducing the Seismic Vulnerability of Existing Buildings Assessment and Retrofit

Reducing the Seismic Vulnerability of Existing Buildings Assessment and Retrofit PDF Author: Tiago Miguel Ferreira
Publisher: MDPI
ISBN: 3039212575
Category : Technology & Engineering
Languages : en
Pages : 184

Get Book Here

Book Description
This book is a printed edition of the Special Issue Reducing the Seismic Vulnerability of Existing Buildings: Assessment and Retrofit that was published in Buildings

4th fib Congress in Mumbai India

4th fib Congress in Mumbai India PDF Author: FIB – International Federation for Structural Concrete
Publisher: FIB - Féd. Int. du Béton
ISBN: 8173719195
Category : Technology & Engineering
Languages : en
Pages : 469

Get Book Here

Book Description


The Building Standard Law of Japan

The Building Standard Law of Japan PDF Author: Japan
Publisher:
ISBN:
Category : Building laws
Languages : en
Pages : 203

Get Book Here

Book Description


Seismic Retrofit of Existing Buildings

Seismic Retrofit of Existing Buildings PDF Author: Matthew Fox
Publisher: Emerald Group Publishing
ISBN: 1835498345
Category : Technology & Engineering
Languages : en
Pages : 309

Get Book Here

Book Description
Seismic Retrofit of Existing Buildings is a concise and easy-to-use guideline for practising engineers to assess and design successful seismic retrofit interventions for existing vulnerable buildings. It offers readers guidance on both conceptual design strategies and relevant detailed design considerations.

Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications

Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications PDF Author: fib Fédération internationale du béton
Publisher: fib Fédération internationale du béton
ISBN: 9782883940758
Category : Technology & Engineering
Languages : en
Pages : 234

Get Book Here

Book Description
fib Bulletin 35 is the first bulletin to publish documentation from an fib short course. These courses are held worldwide and cover advanced knowledge of structural concrete in general, or specific topics. They are organized by fib and given by internationally recognized experts in fib, often supplemented with local experts active in fib. They are based on the knowledge and expertise from fib's ten Commissions and nearly fifty Task Groups. fib Bulletin 35 presents the course materials developed for the short course "Retrofitting of Concrete Structures through Externally Bonded FRP, with emphasis on Seismic Applications", given in Ankara and Istanbul in June 2005. The course drew on expertise both from outside Turkey and from the large pool of local experts on this subject. In most countries of the world, the building stock is ageing and needs continuous maintenance or repair. Moreover, the majority of existing constructions are deficient in the light of current knowledge and design codes. The problem of structural deficiency of existing constructions is especially acute in seismic regions, as, even there, seismic design of structures is relatively recent. The direct and indirect costs of demolition and reconstruction of structurally deficient constructions are often prohibitive; furthermore they entail a substantial waste of natural resources and energy. Therefore, structural retrofitting is becoming increasingly widespread throughout the world. Externally bonded Fibre Reinforced Polymers (FRPs) are rapidly becoming the technique of choice for structural retrofitting. They are cleaner and easier to apply than conventional retrofitting techniques, reduce disruption to the occupancy and operation of the facility, do not generate debris or waste, and reduce health and accident hazards at the construction site as well as noise and air pollution in the surroundings. fib Bulletin 35 gives state-of-the-art coverage of retrofitting through FRPs and presents relevant provisions from three recent standardisation milestones: EN 1998-3:2005 "Eurocode 8: Design of structures for earthquake resistance - Part 3: Assessment and retrofitting of buildings", the 2005 Draft of the Turkish seismic design code, and the Italian regulatory document CNR-DT 200/04, "Instructions for Design, Execution and Control of Strengthening Interventions by Means of Fibre-Reinforced Composites" (2004).