ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE

ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE PDF Author: MARTINE.. CARRE JOUINEAU
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L

ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE

ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D'UN SPECTROMETRE D'EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D'ANALYSE ELEMENTAIRE PDF Author: MARTINE.. CARRE JOUINEAU
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L

Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge

Étude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge PDF Author: Eric de Borniol
Publisher:
ISBN:
Category :
Languages : fr
Pages : 121

Get Book Here

Book Description
L'ETUDE DE L'ATMOSPHERE OU LE SUIVI DE PROCESSUS INDUSTRIELS NECESSITE DES INSTRUMENTS CAPABLES DE MESURER IN SITU ET DE FACON SELECTIVE DE FAIBLES CONCENTRATIONS DE GAZ. LA SPECTROMETRIE D'ABSORPTION PAR DIODE LASER INFRAROUGE REPOND A CE PROBLEME MAIS SA SENSIBILITE EST LIMITEE PAR LE BRUIT DE MESURE. LA PREMIERE PARTIE DE CE MEMOIRE EST CONSACREE A L'ETUDE DES BRUITS LIMITANT LA SENSIBILITE DES METHODES DE SPECTROSCOPIE UTILISANT DES DIODE LASER AUX SELS DE PLOMB, ET AUX DIFFERENTES TECHNIQUES MISES EN UVRE POUR L'AMELIORER. LES FLUCTUATIONS DE PUISSANCE DE LA DIODE LASER ETANT LE FACTEUR LE PLUS LIMITANT POUR LA SENSIBILITE, L'ETUDE DU BRUIT RELATIF D'INTENSITE (OU RIN) D'UNE TELLE SOURCE A ETE REALISEE. CETTE ETUDE MONTRE QUE CE BRUIT PEUT ETRE DIMINUE EN FONCTION DES CONDITIONS EXPERIMENTALES ET QU'IL PRESENTE, DANS TOUT LES CAS, UNE DECROISSANCE AVEC LA FREQUENCE D'ANALYSE (BRUIT EN 1/F). LA SECONDE PARTIE DU MEMOIRE EST DEDIEE A LA CONCEPTION ET A L'EVALUATION DE LA SENSIBILITE ULTIME D'UN SPECTROMETRE D'ABSORPTION DIFFERENTIELLE A BALAYAGE RAPIDE. LA LONGUEUR D'ONDE D'EMISSION EST BALAYEE PERIODIQUEMENT AUTOUR D'UNE RAIE D'ABSORPTION MOLECULAIRE EN MODULANT LE COURANT INJECTE DANS LA DIODE. DEUX VOIES OPTIQUES DE MESURE L'UNE TRAVERSANT LE MILIEU ET L'AUTRE NON SONT SOUSTRAITES L'UNE A L'AUTRE AVANT LA NUMERISATION DU SIGNAL. LE SIGNAL EST ENSUITE MOYENNE SUR PLUSIEURS PERIODES. L'ETUDE DU FILTRE RESULTANT DU BALAYAGE SPECTRAL RAPIDE MONTRE QUE LE BRUIT EN 1/F PEUT ETRE FILTRE EN DIMINUANT LA PERIODE DE MODULATION. LA SOUSTRACTION DE DEUX VOIES ASSOCIE A UNE COURTE PERIODE DE BALAYAGE (0,1 MS) PERMETTENT D'ATTEINDRE UNE TRES GRANDE SENSIBILITE. L'ANALYSE DE SPECTRES D'ABSORPTION DE LA MOLECULE DE CO VERS 2054 CM 1 MONTRE QUE LE SPECTROMETRE REALISE PERMET DE MESURER UNE ABSORPTION RELATIVE DE LA PUISSANCE LASER DE 1,1.10 6 EN 54,5 MS. SA SENSIBILITE LIMITE, CALCULEE POUR UNE BANDE PASSANTE DE 1 HZ EST DE 7.10 8. CETTE SENSIBILITE EST PROCHE DE CELLE OBTENUE PAR LA TECHNIQUE ACTUELLEMENT LA PLUS SENSIBLE TELLE QUE LA SPECTROSCOPIE DE MODULATION HAUTE FREQUENCE.

SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE

SPECTROMETRIE D'EMISSION A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE PDF Author: MARIE-PIERRE.. SOUFFLET
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description


DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS

DETERMINATION DES INTERFERENCES SPECTRALES EN SPECTROMETRIE D'EMISSION ATOMIQUE DE PLASMA INDUIT PAR HAUTE FREQUENCE EN VUE DE L'ANALYSE DES ELEMENTS TRACES ET MINEUR EN PRESENCE DE MAJEURS PDF Author: OLGA.. RODRIGUEZ-DIAZ
Publisher:
ISBN:
Category :
Languages : fr
Pages : 184

Get Book Here

Book Description
ETUDE DES INTERFERENCES SPECTRALES SUR LES RAIES (604) LES PLUS SENSIBLES DE 21 ELEMENTS POUR 57 ELEMENTS INTERFERANTS A UNE CONCENTRATION DE 1 G/L. DETERMINATION DU TYPE D'INTERFERENCES, COINCIDENCE DE RAIES, RECOUVREMENT PARTIEL OU AUGMENTATION DU FOND. APPLICATION SUR UNE MATRICE TUNGSTENE

Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence

Étude et réalisation d'un spectromètre de masse équipé d'une source d'ions à excitation électrique de haute fréquence PDF Author: Jocelyn Garcia
Publisher:
ISBN:
Category :
Languages : fr
Pages : 72

Get Book Here

Book Description


Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge

Etude des bruits limitant la sensibilité d'un spectromètre d'absorption différentielle à diode laser infrarouge PDF Author: Eric de Borniol
Publisher:
ISBN:
Category :
Languages : fr
Pages : 121

Get Book Here

Book Description
L'ETUDE DE L'ATMOSPHERE OU LE SUIVI DE PROCESSUS INDUSTRIELS NECESSITE DES INSTRUMENTS CAPABLES DE MESURER IN SITU ET DE FACON SELECTIVE DE FAIBLES CONCENTRATIONS DE GAZ. LA SPECTROMETRIE D'ABSORPTION PAR DIODE LASER INFRAROUGE REPOND A CE PROBLEME MAIS SA SENSIBILITE EST LIMITEE PAR LE BRUIT DE MESURE. LA PREMIERE PARTIE DE CE MEMOIRE EST CONSACREE A L'ETUDE DES BRUITS LIMITANT LA SENSIBILITE DES METHODES DE SPECTROSCOPIE UTILISANT DES DIODE LASER AUX SELS DE PLOMB, ET AUX DIFFERENTES TECHNIQUES MISES EN UVRE POUR L'AMELIORER. LES FLUCTUATIONS DE PUISSANCE DE LA DIODE LASER ETANT LE FACTEUR LE PLUS LIMITANT POUR LA SENSIBILITE, L'ETUDE DU BRUIT RELATIF D'INTENSITE (OU RIN) D'UNE TELLE SOURCE A ETE REALISEE. CETTE ETUDE MONTRE QUE CE BRUIT PEUT ETRE DIMINUE EN FONCTION DES CONDITIONS EXPERIMENTALES ET QU'IL PRESENTE, DANS TOUT LES CAS, UNE DECROISSANCE AVEC LA FREQUENCE D'ANALYSE (BRUIT EN 1/F). LA SECONDE PARTIE DU MEMOIRE EST DEDIEE A LA CONCEPTION ET A L'EVALUATION DE LA SENSIBILITE ULTIME D'UN SPECTROMETRE D'ABSORPTION DIFFERENTIELLE A BALAYAGE RAPIDE. LA LONGUEUR D'ONDE D'EMISSION EST BALAYEE PERIODIQUEMENT AUTOUR D'UNE RAIE D'ABSORPTION MOLECULAIRE EN MODULANT LE COURANT INJECTE DANS LA DIODE. DEUX VOIES OPTIQUES DE MESURE L'UNE TRAVERSANT LE MILIEU ET L'AUTRE NON SONT SOUSTRAITES L'UNE A L'AUTRE AVANT LA NUMERISATION DU SIGNAL. LE SIGNAL EST ENSUITE MOYENNE SUR PLUSIEURS PERIODES. L'ETUDE DU FILTRE RESULTANT DU BALAYAGE SPECTRAL RAPIDE MONTRE QUE LE BRUIT EN 1/F PEUT ETRE FILTRE EN DIMINUANT LA PERIODE DE MODULATION. LA SOUSTRACTION DE DEUX VOIES ASSOCIE A UNE COURTE PERIODE DE BALAYAGE (0,1 MS) PERMETTENT D'ATTEINDRE UNE TRES GRANDE SENSIBILITE. L'ANALYSE DE SPECTRES D'ABSORPTION DE LA MOLECULE DE CO VERS 2054 CM 1 MONTRE QUE LE SPECTROMETRE REALISE PERMET DE MESURER UNE ABSORPTION RELATIVE DE LA PUISSANCE LASER DE 1,1.10 6 EN 54,5 MS. SA SENSIBILITE LIMITE, CALCULEE POUR UNE BANDE PASSANTE DE 1 HZ EST DE 7.10 8. CETTE SENSIBILITE EST PROCHE DE CELLE OBTENUE PAR LA TECHNIQUE ACTUELLEMENT LA PLUS SENSIBLE TELLE QUE LA SPECTROSCOPIE DE MODULATION HAUTE FREQUENCE.

Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum

Etude de problèmes de filtrage de bruit de fond en spectrométrie nucléaire, amélioration du rapport signal sur bruit et des caractéristiques de l'impulsion mise en forme par le dispositif du prédicteur optimum PDF Author: Jerzy Benda
Publisher:
ISBN:
Category :
Languages : fr
Pages : 52

Get Book Here

Book Description