Comparison of Observer Reliability of Three-dimensional Cephalometric Landmark Identification on Subject Images from Galileos and I-CAT CBCT

Comparison of Observer Reliability of Three-dimensional Cephalometric Landmark Identification on Subject Images from Galileos and I-CAT CBCT PDF Author: Rujuta Amol Katkar
Publisher:
ISBN:
Category : Cephalometry
Languages : en
Pages : 74

Get Book Here

Book Description


Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images

Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images PDF Author: Michael S. Pollack
Publisher:
ISBN:
Category : Dissertations, Academic
Languages : en
Pages : 180

Get Book Here

Book Description


Intra- and Inter-operator Reliability of Cephalometric Landmark Identification

Intra- and Inter-operator Reliability of Cephalometric Landmark Identification PDF Author: Llon Hurst Clendenen
Publisher:
ISBN:
Category :
Languages : en
Pages : 84

Get Book Here

Book Description
The purpose of this study was to compare examiner reliability of cephalometric measurements from cone beam computed tomography (CBCT) and conventional digital cephalograms. Three imaging modalities were compared: CBCT using maximum intensity projection and ray-sum algorithms, and conventional digital cephalograms. Blinded examiners were calibrated, and intra- and inter-examiner reliability were assessed. Data were collected on a convenience sample of seven subjects. Examiners obtained linear and angular measures on each of the subjects' images, and rater consistency among the three methods were assessed using repeated measures analysis of variance of intraclass correlation coefficient ratios. A statistically significantly greater level of consistency for linear measurements was seen with the CBCT images. For the conventional digital images, linear measurements showed less consistency than angular measurements. This statistical significance unlikely correlates to a clinical significance. For orthodontic diagnosis, treatment planning, and treatment evaluation, CBCT generated cephalograms are equally effective to conventional digital cephalograms.

The Reliability of Three-dimensional Computer-generated Linear and Angular Cephalometric Measurements

The Reliability of Three-dimensional Computer-generated Linear and Angular Cephalometric Measurements PDF Author: Budi Kusnoto
Publisher:
ISBN:
Category : Cephalometry
Languages : en
Pages : 192

Get Book Here

Book Description


Comparative Accuracy of Linear Measures from Conventional Digital and Cone Beam Computed Tomography Simulated Posterior Anterior Cephalograms

Comparative Accuracy of Linear Measures from Conventional Digital and Cone Beam Computed Tomography Simulated Posterior Anterior Cephalograms PDF Author: Brian M. Mannari
Publisher:
ISBN:
Category : Dental care
Languages : en
Pages : 152

Get Book Here

Book Description
The purpose of this project was to compare the accuracy and reliability of linear measurements on posterior-anterior (PA) cephalograms made conventionally using photostimulable storage phosphor imaging plates (PSP) and simulated PA cephalometric images from ray sum reconstruction of cone beam computed tomographic (CBCT) volumetric datasets of the same anatomic specimens. The sample consisted of 19 dried dentate human skulls which were imaged using PA cephalometry using PSP imaging plates and three CBCT datasets at 10 s., 20 s. and 40 s. scanning times from which ray sum simulated PA images were produced. Various anatomic landmarks were identified and truth measurements of 13 selected cephalometric linear dimensions were measured directly on the skulls using a high precision caliper. CBCT datasets were imported into a reconstruction program (Dolphin 3D Software) from which ray sum PA images were constructed. Linear cephalometric measurements on PSP and CBCT simulated PA images were performed by one observer using Dolphin Imaging Software. Intraobserver reliability was determined by calculating and comparing Intraclass correlation coefficient. Mean absolute and percentage errors were calculated for each dimension and modality to quantify the reliability error. Mean modality measurements were compared. All other groups were compared using one-way ANOVA with Tukey post hoc comparisons (p [less than or equal to] 0.05). While the ICC was high, PSP cephalometric absolute error was greater than anatomic distances and CBCT image measurements for 8 for 13 measurements. We found that for most measurements, simulated PA images produced from reconstructed CBCT volumetric dataset were accurate and compared well to PSP cephalometric images except for Z-Ag. We also found that PSP cephalometric images consistently underestimated MO-MO dimensions. Measurements on CBCT simulated PA images are more reliabile and as accuracte as PSP cephalometric measurements. The number of projections comprising the reconstructed simulated PA image did not influence reliability or accuracy. Therefore in accordance with ALARA, when CBCT imaging is used to generate simulated PA images, the lowest number of projections are recommended.

Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2-dimensional Images and Conventional Lateral Cephalometric Images Using Photostimulable Storage Phosphors

Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2-dimensional Images and Conventional Lateral Cephalometric Images Using Photostimulable Storage Phosphors PDF Author: Mazyar Moshiri
Publisher:
ISBN:
Category : Teeth
Languages : en
Pages : 168

Get Book Here

Book Description
The purpose of this project was to compare the accuracy and precision of linear measurements made on conventional lateral cephalograms (LC) and simulated LC using cone-beam computed tomography (CBCT) to direct measurements on dentate skulls. The linear distances for 5 mid-sagittal and 4 bilateral measurements between anatomical landmarks on 22 skulls were measured by two observers. The skulls were imaged using a CBCT scanner at 4 scan settings: high resolution (0.2mm) and normal resolution (0.4mm) at 20-sec (306 projections) and 40-sec scans (612 projections). Three simulated LC were generated: Ray sum image reconstructions of the maximum thickness mid-sagittal multiplanar projections, a single frame basis projection, and the scout image. LCs were acquired using a storage phosphor system. Projection images were exported into a cephalometric analysis program and linear measurements determined. Analyses were repeated three times and statistically compared to measured anatomic truth using repeated measures general linear model (p [less than or equal to] 0.05). The mean absolute error was used as an index of precision. While there were statistical differences between skull and modality measurements for 6 of the nine measurements, there were no overall differences between LC and CBCT derived image measurements irrespective of method of construction. CBCT imaging provides clinically reliable 2D simulation images however, dose considerations demand that evidence-based selection criteria should be developed for CBCT in orthodontics that take into account the ALARA principle.

Cone Beam Computed Tomography in Orthodontics

Cone Beam Computed Tomography in Orthodontics PDF Author: Sunil D. Kapila
Publisher: John Wiley & Sons
ISBN: 1118646592
Category : Medical
Languages : en
Pages : 880

Get Book Here

Book Description
Since its introduction to dentistry, cone beam computed tomography (CBCT) has undergone a rapid evolution and considerable integration into orthodontics. However, despite the increasing popularity of CBCT and progress in applying it to clinical orthodontics, the profession has lacked a cohesive, comprehensive and objective reference that provides clinicians with the background needed to utilize this technology optimally for treating their patients. Cone Beam Computed Tomography in Orthodontics provides timely, impartial, and state-of-the-art information on the indications and protocols for CBCT imaging in orthodontics, clinical insights gained from these images, and innovations driven by these insights. As such, it is the most current and authoritative textbook on CBCT in orthodontics. Cone Beam Computed Tomography in Orthodontics is organized to progress sequentially through specific topics so as to build the knowledgebase logically in this important and rapidly evolving field. Part I provides the foundational information on CBCT technology, including radiation exposure and risks, and future evolutions in computed tomography. Part II presents the Principles and Protocols for CBCT Imaging in Orthodontics, focusing on developing evidence-based criteria for CBCT imaging, the medico-legal implications of CBCT to the professional and the protocols and integration of this technology in orthodontic practice. Part III provides critical information on CBCT-based Diagnosis and Treatment Planning that includes how to interpret CBCT scans, identify incidental pathologies and the possible other uses of this technology. Part IV covers practical aspects of CBCT’s Clinical Applications and Treatment Outcomes that encompasses a range of topics, including root morphology and position, treatment of impacted teeth, virtual surgical treatment planning and outcomes, and more.

Clinical Orthodontics: Current Concepts, Goals and Mechanics

Clinical Orthodontics: Current Concepts, Goals and Mechanics PDF Author: Ashok Karad
Publisher: Elsevier Health Sciences
ISBN: 8131237400
Category : Medical
Languages : en
Pages : 541

Get Book Here

Book Description
- Craniofacial Growth: A Clinical Perspective - Role of Skeletal Anchorage in Modern Orthodontics - Optimizing Orthodontic Treatment

Craniofacial 3D Imaging

Craniofacial 3D Imaging PDF Author: Onur Kadioglu
Publisher: Springer
ISBN: 3030007227
Category : Medical
Languages : en
Pages : 251

Get Book Here

Book Description
This book is designed to serve as an up-to-date reference on the use of cone-beam computed tomography for the purpose of 3D imaging of the craniofacial complex. The focus is in particular on the ways in which craniofacial 3D imaging changes how we think about conventional diagnosis and treatment planning and on its clinical applications within orthodontics and oral and maxillofacial surgery. Emphasis is placed on the value of 3D imaging in visualizing the limits of the alveolar bone, the airways, and the temporomandibular joints and the consequences for treatment planning and execution. The book will equip readers with the knowledge required in order to apply and interpret 3D imaging to the benefit of patients. All of the authors have been carefully selected on the basis of their expertise in the field. In describing current thinking on the merits of 3D craniofacial imaging, they draw both on the available scientific literature and on their own translational research findings.

CT Scanning

CT Scanning PDF Author: Karupppasamy Subburaj
Publisher: BoD – Books on Demand
ISBN: 9533079436
Category : Medical
Languages : en
Pages : 362

Get Book Here

Book Description
Since its introduction in 1972, X-ray computed tomography (CT) has evolved into an essential diagnostic imaging tool for a continually increasing variety of clinical applications. The goal of this book was not simply to summarize currently available CT imaging techniques but also to provide clinical perspectives, advances in hybrid technologies, new applications other than medicine and an outlook on future developments. Major experts in this growing field contributed to this book, which is geared to radiologists, orthopedic surgeons, engineers, and clinical and basic researchers. We believe that CT scanning is an effective and essential tools in treatment planning, basic understanding of physiology, and and tackling the ever-increasing challenge of diagnosis in our society.