An Assessment on the Non-Invasive Methods for Condition Monitoring of Induction Motors

An Assessment on the Non-Invasive Methods for Condition Monitoring of Induction Motors PDF Author: Muhammad Irfan
Publisher:
ISBN:
Category : Science
Languages : en
Pages :

Get Book Here

Book Description
The ability to forecast motor mechanical faults at incipient stages is vital to reducing maintenance costs, operation downtime and safety hazards. This paper synthesized the progress in the research and development in condition monitoring and fault diagnosis of induction motors. The motor condition monitoring techniques are mainly classified into two categories that are invasive and non-invasive techniques. The invasive techniques are very basic, but they have some implementation difficulties and high cost. The non-invasive methods, namely MCSA, PVA and IPA, overcome the disadvantages associated to invasive methods. This book chapter reviews the various non-invasive condition monitoring methods for diagnosis of mechanical faults in induction motor and concludes that the instantaneous power analysis (IPA) and Park vector analysis (PVA) methods are best suitable for the diagnosis of small fault signatures associated to mechanical faults. Recommendations for the future research in these areas are also presented.

An Assessment on the Non-Invasive Methods for Condition Monitoring of Induction Motors

An Assessment on the Non-Invasive Methods for Condition Monitoring of Induction Motors PDF Author: Muhammad Irfan
Publisher:
ISBN:
Category : Science
Languages : en
Pages :

Get Book Here

Book Description
The ability to forecast motor mechanical faults at incipient stages is vital to reducing maintenance costs, operation downtime and safety hazards. This paper synthesized the progress in the research and development in condition monitoring and fault diagnosis of induction motors. The motor condition monitoring techniques are mainly classified into two categories that are invasive and non-invasive techniques. The invasive techniques are very basic, but they have some implementation difficulties and high cost. The non-invasive methods, namely MCSA, PVA and IPA, overcome the disadvantages associated to invasive methods. This book chapter reviews the various non-invasive condition monitoring methods for diagnosis of mechanical faults in induction motor and concludes that the instantaneous power analysis (IPA) and Park vector analysis (PVA) methods are best suitable for the diagnosis of small fault signatures associated to mechanical faults. Recommendations for the future research in these areas are also presented.

Condition Monitoring and Faults Diagnosis of Induction Motors

Condition Monitoring and Faults Diagnosis of Induction Motors PDF Author: Nordin Saad
Publisher: CRC Press
ISBN: 1351172557
Category : Technology & Engineering
Languages : en
Pages : 150

Get Book Here

Book Description
The book covers various issues related to machinery condition monitoring, signal processing and conditioning, instrumentation and measurements, faults for induction motors failures, new trends in condition monitoring, and the fault identification process using motor currents electrical signature analysis. It aims to present a new non-invasive and non-intrusive condition monitoring system, which has the capability to detect various defects in induction motor at incipient stages within an arbitrary noise conditions. The performance of the developed system has been analyzed theoretically and experimentally under various loading conditions of the motor. Covers current and new approaches applied to fault diagnosis and condition monitoring. Integrates concepts and practical implementation of electrical signature analysis. Utilizes LabVIEW tool for condition monitoring problems. Incorporates real-world case studies. Paves way a technology potentially for prescriptive maintenance via IIoT.

Noninvasive Methods for Condition Monitoring and Electrical Fault Diagnosis of Induction Motors

Noninvasive Methods for Condition Monitoring and Electrical Fault Diagnosis of Induction Motors PDF Author: Muhammad Aman Sheikh
Publisher:
ISBN:
Category : Science
Languages : en
Pages :

Get Book Here

Book Description
This chapter provides a comprehensive analysis of noninvasive methods to diagnose stator winding insulation faults of an induction motor. Further, a novel noninvasive method is proposed to diagnose the root cause of winding failure due to unbalanced voltage to avoid catastrophic failure. Therefore, a winding function approach is utilized to derive an analytical expression for stator winding distribution and magnetomotive force (MMF). This tactic qualifies the conductor segment that generates MMF, and it also helps to analyze a healthy current spectrum. One can easily observe higher order harmonics in current spectrum; therefore, a new series of rotor harmonics is introduced to diagnose unbalanced supply. The locus of these harmonics is dependent on the poles, rotor bars, and slip. Due to the rapid complexity in industrial plants, it is inconceivable to continue human inspection to diagnose the faults. Thus, to avoid human inspection, in addition to new series of rotor harmonic, a fully automatic method based on neural network is proposed. This method not only diagnoses unbalanced voltage but it also recognize the percentage of unbalanced voltage by use of feed-forward multilayer perceptron (MLP) trained by back propagation. Finally, the experimental results shows the validation of this research work proposed method.

Vibration Monitoring of Induction Motors

Vibration Monitoring of Induction Motors PDF Author: William T. Thomson
Publisher: Cambridge University Press
ISBN: 1108489974
Category : Business & Economics
Languages : en
Pages : 309

Get Book Here

Book Description
Master the art of vibration monitoring of induction motors with this unique guide to on-line condition assessment and fault diagnosis, building on the author's fifty years of investigative expertise. It includes: *Robust techniques for diagnosing of a wide range of common faults, including shaft misalignment and/or soft foot, rolling element bearing faults, sleeve bearing faults, magnetic and vibrational issues, resonance in vertical motor drives, and vibration and acoustic noise from inverters. *Detailed technical coverage of thirty real-world industrial case studies, from initial vibration spectrum analysis through to fault diagnosis and final strip-down. *An introduction to real-world vibration spectrum analysis for fault diagnosis, and practical guidelines to reduce bearing failure through effective grease management. This definitive book is essential reading for industrial end-users, engineers, and technicians working in motor design, manufacturing, and condition monitoring. It will also be of interest to researchers and graduate students working on condition monitoring.

Fault Diagnosis and Detection

Fault Diagnosis and Detection PDF Author: Mustafa Demetgul
Publisher: BoD – Books on Demand
ISBN: 9535132032
Category : Science
Languages : en
Pages : 338

Get Book Here

Book Description
Mass production companies have become obliged to reduce their production costs and sell more products with lower profit margins in order to survive in competitive market conditions. The complexity and automation level of machinery are continuously growing. This development calls for some of the most critical issues that are reliability and dependability of automatic systems. In the future, machines will be monitored remotely, and computer-aided techniques will be employed to detect faults in the future, and also there will be unmanned factories where machines and systems communicate to each other, detect their own faults, and can remotely intercept their faults. The pioneer studies of such systems are fault diagnosis studies. Thus, we hope that this book will contribute to the literature in this regard.

Induction Machine Performance Non Invasive Assessment

Induction Machine Performance Non Invasive Assessment PDF Author: Sridevi R
Publisher: Self Publisher
ISBN: 9781835800782
Category : Computers
Languages : en
Pages : 0

Get Book Here

Book Description
"Induction Machine Performance Non-Invasive Assessment" by Sridevi R is a comprehensive and authoritative book that delves into the field of assessing and diagnosing the performance of induction machines through non-invasive techniques. This book provides a valuable resource for engineers, researchers, and practitioners seeking to enhance the reliability and efficiency of induction machines. The book covers a wide range of topics related to induction machine performance, including motor fault diagnosis, stator winding faults, rotor faults, bearing faults, eccentricity, broken rotor bars, inter-turn short circuits, and insulation degradation. It explores various diagnostic techniques such as vibration analysis, current signature analysis, voltage signature analysis, acoustic emission, temperature monitoring, thermal imaging, and electrical signature analysis. The author emphasizes both online and offline monitoring approaches for fault detection, classification, localization, and severity assessment. The book explores the use of advanced technologies such as machine learning, artificial intelligence, and data analytics for feature extraction, pattern recognition, and signal processing. It also presents diagnostic algorithms, fault indicators, and fault signatures for accurate fault identification, prognosis, and prediction. Throughout the book, the author focuses on electrical and mechanical faults, analyzing fault trends, patterns, and characteristics. The book provides insights into fault mitigation strategies, maintenance optimization, and performance optimization for induction machines. "Induction Machine Performance Non-Invasive Assessment" is a valuable reference for understanding and implementing effective non-invasive assessment techniques, ultimately enhancing the reliability, performance, and lifespan of induction machines in various industrial applications.

Advanced Condition Monitoring and Fault Diagnosis of Electric Machines

Advanced Condition Monitoring and Fault Diagnosis of Electric Machines PDF Author: Irfan, Muhammad
Publisher: IGI Global
ISBN: 1522569901
Category : Technology & Engineering
Languages : en
Pages : 326

Get Book Here

Book Description
The reliability of induction motors is a major requirement in many industrial applications. It is especially important where an unexpected breakdown might result in the interruption of critical services such as military operations, transportation, aviation, and medical applications. Advanced Condition Monitoring and Fault Diagnosis of Electric Machines is a collection of innovative research on various issues related to machinery condition monitoring, signal processing and conditioning, instrumentation and measurements, and new trends in condition monitoring. It also pays special attention to the fault identification process. While highlighting topics including spectral analysis, electrical engineering, and bearing faults, this book is an ideal reference source for electrical engineers, mechanical engineers, researchers, and graduate-level students seeking current research on various methods of maintaining machinery.

Current Signature Analysis for Condition Monitoring of Cage Induction Motors

Current Signature Analysis for Condition Monitoring of Cage Induction Motors PDF Author: William T. Thomson
Publisher: John Wiley & Sons
ISBN: 1119029597
Category : Technology & Engineering
Languages : en
Pages : 438

Get Book Here

Book Description
Provides coverage of Motor Current Signature Analysis (MCSA) for cage induction motors This book is primarily for industrial engineers. It has 13 chapters and contains a unique data base of 50 industrial case histories on the application of MCSA to diagnose broken rotor bars or unacceptable levels of airgap eccentricity in cage induction motors with ratings from 127 kW (170 H.P.) up to 10,160 kW (13,620 H.P.). There are also unsuccessful case histories, which is another unique feature of the book. The case studies also illustrate the effects of mechanical load dynamics downstream of the motor on the interpretation of current signatures. A number of cases are presented where abnormal operation of the driven load was diagnosed. Chapter 13 presents a critical appraisal of MCSA including successes, failures and lessons learned via industrial case histories. The case histories are presented in a step by step format, with predictions and outcomes supported by current spectra and photographic evidence to confirm a correct or incorrect diagnosis The case histories are presented in detail so readers fully understand the diagnosis The authors have 108 years of combined experience in the installation, maintenance, repair, design, manufacture, operation and condition monitoring of SCIMs There are 10 questions at the end of chapters 1 to 12 and answers can be obtained via the publisher Current Signature Analysis for Condition Monitoring of Cage Induction Motors serves as a reference for professional engineers, head electricians and technicians working with induction motors. To obtain the solutions manual for this book, please send an email to [email protected]. William T. Thomson is Director and Consultant with EM Diagnostics Ltd, in Scotland. Prof. Thomson received a BSc (Hons) in Electrical Engineering in 1973 and an MSc in 1977 from the University of Strathclyde. He has published 72 papers on condition monitoring of induction motors in a variety of engineering journals such as IEEE Transactions (USA), IEE Proceedings (UK), and also at numerous International IEEE and IEE conferences. He is a senior member of the IEEE, a fellow of the IEE (IET) in the UK and a Chartered Professional Engineer registered in the UK. Ian Culbert was a Rotating Machines Specialist at Iris Power Qualitrol since April 2002 until his very untimely death on 8th September, 2015. At this company he provided consulting services to customers, assisted in product development, trained sales and field service staff and reviewed stator winding partial discharge reports. He has co-authored two books on electrical machine insulation design, evaluation, aging, testing and repair and was principal author of a number of Electric Power Research Institute reports on motor repair. Ian was a Registered Professional Engineer in the Province of Ontario, Canada and a Senior Member of IEEE.

Fault Diagnosis of Induction Motors

Fault Diagnosis of Induction Motors PDF Author: Jawad Faiz
Publisher: IET
ISBN: 1785613286
Category : Business & Economics
Languages : en
Pages : 535

Get Book Here

Book Description
This book is a comprehensive, structural approach to fault diagnosis strategy. The different fault types, signal processing techniques, and loss characterisation are addressed in the book. This is essential reading for work with induction motors for transportation and energy.

Recent Trends in the Condition Monitoring of Transformers

Recent Trends in the Condition Monitoring of Transformers PDF Author: Sivaji Chakravorti
Publisher: Springer Science & Business Media
ISBN: 1447155505
Category : Business & Economics
Languages : en
Pages : 289

Get Book Here

Book Description
Recent Trends in the Condition Monitoring of Transformers reflects the current interest in replacing traditional techniques used in power transformer condition monitoring with non-invasive measures such as polarization/depolarization current measurement, recovery voltage measurement, frequency domain spectroscopy and frequency response analysis. The book stresses the importance of scrutinizing the condition of transformer insulation which may fail under present day conditions of intensive use with the resulting degradation of dielectric properties causing functional failure of the transformer. The text shows the reader how to overcome the key challenges facing today’s maintenance policies, namely: The selection of appropriate techniques for dealing with each type of failure process accounting for the needs of plant owners, plant users and wider society; and Cost-efficiency and durability of effect. Many of the failure-management methods presented rely on the fact that most failures give warning when they are imminent. These potential failures give rise to identifiable physical conditions and the novel approaches described detect them so that action can be taken to avoid degeneration into full-blown functional failure. This “on-condition” maintenance means that equipment can be left in service as long as a specified set of performance standards continue to be met, avoiding the costly downtime imposed by routine and perhaps unnecessary maintenance but without risking equally expensive failure. Recent Trends in the Condition Monitoring of Transformers will be of considerable interest to both academic researchers in power systems and to engineers working in the power generation and distribution industry showing how new and more efficient methods of fault diagnosis and condition management can increase transformer efficiency and cut costs.