Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring

Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers sub-critically annealed electric resistance welded and cold-drawn single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, welding and brazing.The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications than like sizes of the grades of material specified in SAE J525 and SAE J2467. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J525 and SAE J2467. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing.CAUTION: When brazing or welding is used as a tube end joining method, the structural integrity of the tube material can potentially be compromised due to the degradation of the areas affected by the thermal effect applied to the tubing; therefore, the ISO 10763 and SAE J1065 nominal reference working pressures may not be applicable.Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity. This SAE standard has been revised as part of the SAE five year review process and to bring this document into line with global standardization.

Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring

Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers sub-critically annealed electric resistance welded and cold-drawn single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, welding and brazing.The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications than like sizes of the grades of material specified in SAE J525 and SAE J2467. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J525 and SAE J2467. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing.CAUTION: When brazing or welding is used as a tube end joining method, the structural integrity of the tube material can potentially be compromised due to the degradation of the areas affected by the thermal effect applied to the tubing; therefore, the ISO 10763 and SAE J1065 nominal reference working pressures may not be applicable.Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity. This SAE standard has been revised as part of the SAE five year review process and to bring this document into line with global standardization.

Welded and Cold-Drawn, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending and Flaring

Welded and Cold-Drawn, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending and Flaring PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers sub-critically annealed electric resistance welded and cold-drawn single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, welding and brazing.The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications using thinner walls than like sizes of the grades of material specified in SAE J525, SAE J2467 and SAE J2614. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J525, SAE J2467 and SAE J2614. Nominal reference working pressures for this tubing are listed in ISO 10763 and SAE J1065.Caution: When brazing or welding is used as a tube end joining method, the structural integrity of the tube material can potentially be compromised due to the degradation of the areas affected by the thermal effect applied to the tubing; therefore, the ISO 10763 and SAE J1065 nominal reference working pressures may not be applicable.Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity. The working pressures of the modern day mobile equipment hydraulic systems have risen dramatically as compared to the hydraulic pressures in the past. This new hydraulic tubing material has been developed to fill the needs of the hydraulic industry by providing a tube material matched with modern day high pressure hydraulic hose and connectors to help resolve the hydraulic system space constraints and routing issues faced by today's system designers in the hydraulic mobile equipment industry. Aircraft and Aerospace applications were not considered during the preparation of this document.

Welded and Cold-Drawn, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending, Flaring, Cold Forming and Brazing

Welded and Cold-Drawn, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending, Flaring, Cold Forming and Brazing PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers stress relieved annealed electric resistance welded and cold-drawn single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, and brazing.The grade of material produced to this specification is of micro-alloy content. Nominal reference working pressures for this tubing are listed in ISO 10763 and SAE J1065.CAUTION: Sub-critically annealed steels are often produced using anneal temperatures below the Lower Critical Temperature (AC1) of the given steel to achieve the desired strength levels. Welding, brazing, or other processing methods that subject the tube material or assembly to temperatures near or above AC1 might initiate isothermal transformation of the tube microstructure and compromise the strength of the tube in the heat affected zone by further annealing the tube. Therefore, ISO 10763 and SAE J1065 nominal reference working pressures might not be applicable. It is recommended that the user and the fabricator validate and agree that the tube assembly design and pressure ratings are not compromised beyond system design from these processes. Performance testing as described in SAE J2551-2 will facilitate appropriate test recommendations.Brazed and/or welded tube assembly configurations made to specific geometry and components in association with this material may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end connections in place of thermal processes such as brazing and welding avoids this systemic testing by not compromising the structural integrity of the tube material.In an effort to standardize within a global marketplace and ensure that companies can remain competitive in an international market, it is the intent to convert to metric tube sizes which will: Lead to one global system Guide users to preferred system Reduce complexity Eliminate inventory duplications This SAE Standard has been revised as part of a Five-Year Review. Document changes include revisions to the Scope, Applicable and Related Publications lists, updated thermal process warning, additional Section 3 Manufacture drawing requirement and Section 8.8 Pressure Proof Test information. Verbiage has been updated throughout the standard to align the document with other recently revised tube standards.

Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Hydraulic Tubing, for Bending, Flaring, Cold Forming, Welding and Brazing

Welded and Cold-Drawn, High Strength (500 MPa Tensile Strength) Hydraulic Tubing, for Bending, Flaring, Cold Forming, Welding and Brazing PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers sub-critically annealed or normalized electric resistance welded and cold-drawn single-wall high strength steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, welding and brazing. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing.This specification also covers SAE J2614 Type-A tubing. The mechanical properties and performance requirements of standard SAE J2614 and SAE J2614 Type-A are the same. The designated differences of Type-A tubing do not imply that Type-A tubing is in anyway inferior to standard SAE J2614. The Type-A designation is meant to address unique manufacturing differences between sub-critically annealed and normalized tubing. Tube assembly configurations made to specific geometry and components requiring thermal attachment methods in association with the sub-critically annealed material, may require qualification testing in accordance with ISO 19879. The use of Type-A material avoids this systemic testing as thermal processes will not compromise the structural integrity of the Type-A tube material.In an effort to standardize within a global marketplace and ensure that companies can remain competitive in an international market, it is the intent to convert to metric tube sizes which will: Lead to one global system Guide users to preferred system Reduce complexity Eliminate inventory duplications This SAE standard has been revised as part of a Five-Year Review to reflect changes in available steels and newly developed processes used to produce this product. Document changes include revisions to the Scope, Applicable and Related Publications list, Section 8.8 Pressure Proof Test information and the addition of SAE J2614 Type-A material. Verbiage has been updated throughout the standard to align the document with other recently revised tube standards.

Welded Flash Controlled, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending, Double Flaring, and Bending

Welded Flash Controlled, High Strength (500 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending, Double Flaring, and Bending PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This SAE Standard covers sub-critically annealed electric resistance welded flash controlled single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, cold forming, welding and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead.The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications than like sizes of the grades of material specified in SAE J356 and SAE J2435. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J356 and SAE J2435. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing.CAUTION: When brazing or welding is used as a tube end joining method, the structural integrity of the tube material can potentially be compromised due to the degradation of the areas affected by the thermal effect applied to the tubing; therefore, the ISO 10763 and SAE J1065 nominal reference working pressures may not be applicable.Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity. This SAE standard has been revised as part of the SAE five year review process and to bring this document into line with global standardization.

Welded and Cold-Drawn, High Strength Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring

Welded and Cold-Drawn, High Strength Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending and Flaring PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This specification covers sub-critically annealed electric resistance welded and cold-drawn single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, cold forming, welding and brazing. The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications than like sizes of the grades of material specified in SAE J525 and SAE J2467. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J525 and SAE J2467. Nominal reference working pressures for this tubing are listed in SAE J1065.

Welded Flash Controlled, High Strength (500 MPa Tensile Strength) Hydraulic Tubing, for Bending, Double Flaring, Cold Forming, Welding, and Brazing

Welded Flash Controlled, High Strength (500 MPa Tensile Strength) Hydraulic Tubing, for Bending, Double Flaring, Cold Forming, Welding, and Brazing PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This SAE Standard covers sub-critically annealed or normalized electric resistance welded flash controlled single-wall high strength steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, cold forming, welding and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path caused by the ID weld bead. Nominal reference working pressures for this tubing are listed in ISO 10763 for metric tubing and SAE J1065 for inch tubing.This specification also covers SAE J2613 Type-A tubing. The mechanical properties and performance requirements of standard SAE J2613 and SAE J2613 Type-A are the same. The designated differences of Type-A tubing do not imply that Type-A tubing is in anyway inferior to standard SAE J2613. The Type-A disignation is meant to address the unique manufacturing differences between sub-critically annealed and normalized tubing. Tube assembly configurations made to specific geometry and components requiring thermal attachment methods in association with the sub-critically annealed material, may require qualification testing in accordance with ISO 19879. The use of Type-A material avoids this systemic testing as thermal processes will not compromise the structural integrity of the Type-A tube material.In an effort to standardize within a global marketplace and ensuring that companies can remain competitive in an international market it is the intent to convert to metric tube sizes which will: Lead to one global system Guide users to preferred system Reduce complexity Eliminate inventory duplications This SAE standard has been revised as part of a Five-Year Review to reflect changes in available steels and newly developed processes used to produce this product. Document changes include revisions to the Scope, Applicable and Related Publications list, Section 8.8 Pressure Proof Test information and the addition of J2613 Type-A material. Verbiage has been updated throughout the standard to align the document with other recently revised tube standards.

Welded Flash Controlled, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending and Double Flaring

Welded Flash Controlled, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending and Double Flaring PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This SAE Standard covers stress relieved electric resistance welded flash controlled single wall high strength low alloy steel tubing intended for use in high pressure hydraulic lines and in other applications requiring tubing of a quality suitable for bending, double flaring and cold forming. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead.The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications using thinner walls than like sizes of the grades of material specified in SAE J356, SAE J2435 and SAE J2613. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J356, SAE J2435 and SAE J2613. Nominal reference working pressures for this tubing are listed in ISO 10763 and SAE J1065. Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with ISO 19879 Test Methods for Hydraulic Fluid Power Connections. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity. The working pressures of the modern day mobile equipment hydraulic systems have risen dramatically as compared to the hydraulic pressures in the past. This new hydraulic tubing material has been developed to fill the needs of the hydraulic industry by providing a tube material matched with modern day high pressure hydraulic hose and connectors to help resolve the hydraulic system space constraints and routing issues faced by today's system designers in the hydraulic mobile equipment industry. Aircraft and Aerospace applications were not considered during the preparation of this document.

Welded Flash Controlled, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved, Annealed for Bending, Double Flaring, Cold Forming, and Brazing

Welded Flash Controlled, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved, Annealed for Bending, Double Flaring, Cold Forming, and Brazing PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This SAE Standard covers stress relieved electric resistance welded flash controlled single wall high strength low alloy steel tubing intended for use in high-pressure hydraulic lines and in other applications requiring tubing of a quality suitable for bending, double flaring,cold forming and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path caused by the ID weld bead. The grade of material produced to this specification is of micro-alloy content. Nominal reference working pressures for this tubing are listed in ISO 10763 and SAE J1065. Brazed and/or welded tube assembly configurations made to specific geometry and components in association with this material may require qualification testing in accordance with ISO 19879. Cold forming the tube end configurations avoids this systemic testing by not compromising the structural integrity of the tube material.In an effort to standardize within a global marketplace and ensure that companies can remain competitive in an international market, it is the intent to convert to metric tube sizes, which will: Lead to one global system Guide users to preferred system Reduce complexity Eliminate inventory duplications This SAE Standard has been revised as part of a Five-Year Review. Document changes include: revisions to the scope, applicable documents, and related publications lists; updated thermal process warning; new verbiage in 5.2; clarified 5.3 requirement; and revised or added notes to 8.8 and 8.9. Verbiage has been updated throughout the standard to align the document with other recently revised tube standards.

Welded Flash Controlled, High Strength Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending, Double Flaring, and Bending

Welded Flash Controlled, High Strength Low Alloy Steel Hydraulic Tubing, Sub-Critically Annealed for Bending, Double Flaring, and Bending PDF Author: Metallic Tubing Committee
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This SAE Standard covers sub-critically annealed electric resistance welded flash controlled single-wall high strength low alloy steel tubing intended for use in hydraulic pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, cold forming, welding and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead. The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications than like sizes of the grades of material specified in SAE J356 and SAE J2435. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J356 and SAE J2435. Nominal reference working pressures for this tubing are listed in SAE J1065.