The Behaviour of Ultra-high-performance Concrete in Precast Concrete Bridge Deck Connections

The Behaviour of Ultra-high-performance Concrete in Precast Concrete Bridge Deck Connections PDF Author: Heather Stefaniuk
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This thesis studies the behaviour of ultra-high-performance concrete (UHPC) in the precast concrete bridge deck connections. The experimental program consisted of shear pocket push-out testing and full-scale bridge deck testing. The main objective was to study the UHPC performance in the shear pocket and joint connections. All specimens were statically loaded until failure. The push-out test specimens consisted of two small 45 MPa concrete slabs on either side of a built-up steel section, joined together by shear studs and UHPC shear pockets. There were three 6-stud specimens, two 3-stud specimens and two 0-stud specimens. The 6-stud specimens reached ultimate loads of 2642 kN, 2892 kN, and 3045 kN. The 3-stud specimens reached ultimate loads of 1445 kN and 1674 kN. The 0-stud specimens reached ultimate loads of 4.91 kN and 3.44 kN. The failure modes for the 6-stud and 3-stud specimens were stud failure or concrete crushing, while the 0-stud specimens failed when the UHPC and steel section surface debonded. The push-out specimens were instrumented with LVDTs, pi-gauges and strain gauges to collect data on the displacements, debonding, and shear stud strains throughout testing. The bridge deck testing included a full panel deck (FPD) and jointed panel deck (JPD). The FPD was cast monolithically with regular strength concrete and had UHPC shear pocket connections to the steel support girders. The JPD was cast as two half-size regular strength panels connected together with a UHPC joint, and connected to the steel support girders with UHPC shear pockets. The FPD and JPD reached ultimate loads of 1926 kN and 1878 kN, respectively. Both decks failed by concrete punching under the load point. The bridge decks were instrumented with LVDTs, pi-gauges, and strain gauges to collect data on the deflections, crack widths, steel strains, concrete strains, and shear stud strains throughout testing. The experimental results implied the number and length of the studs in the shear pockets may be reduced. The better performance of the FPD also indicated the circular pockets were superior and the use of UHPC in precast deck connections does not significantly improve the overall performance.

The Behaviour of Ultra-high-performance Concrete in Precast Concrete Bridge Deck Connections

The Behaviour of Ultra-high-performance Concrete in Precast Concrete Bridge Deck Connections PDF Author: Heather Stefaniuk
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
This thesis studies the behaviour of ultra-high-performance concrete (UHPC) in the precast concrete bridge deck connections. The experimental program consisted of shear pocket push-out testing and full-scale bridge deck testing. The main objective was to study the UHPC performance in the shear pocket and joint connections. All specimens were statically loaded until failure. The push-out test specimens consisted of two small 45 MPa concrete slabs on either side of a built-up steel section, joined together by shear studs and UHPC shear pockets. There were three 6-stud specimens, two 3-stud specimens and two 0-stud specimens. The 6-stud specimens reached ultimate loads of 2642 kN, 2892 kN, and 3045 kN. The 3-stud specimens reached ultimate loads of 1445 kN and 1674 kN. The 0-stud specimens reached ultimate loads of 4.91 kN and 3.44 kN. The failure modes for the 6-stud and 3-stud specimens were stud failure or concrete crushing, while the 0-stud specimens failed when the UHPC and steel section surface debonded. The push-out specimens were instrumented with LVDTs, pi-gauges and strain gauges to collect data on the displacements, debonding, and shear stud strains throughout testing. The bridge deck testing included a full panel deck (FPD) and jointed panel deck (JPD). The FPD was cast monolithically with regular strength concrete and had UHPC shear pocket connections to the steel support girders. The JPD was cast as two half-size regular strength panels connected together with a UHPC joint, and connected to the steel support girders with UHPC shear pockets. The FPD and JPD reached ultimate loads of 1926 kN and 1878 kN, respectively. Both decks failed by concrete punching under the load point. The bridge decks were instrumented with LVDTs, pi-gauges, and strain gauges to collect data on the deflections, crack widths, steel strains, concrete strains, and shear stud strains throughout testing. The experimental results implied the number and length of the studs in the shear pockets may be reduced. The better performance of the FPD also indicated the circular pockets were superior and the use of UHPC in precast deck connections does not significantly improve the overall performance.

Behavior of Field-cast Ultra-high Performance Concrete Bridge Deck Connections Under Cyclic and Static Structural Loading

Behavior of Field-cast Ultra-high Performance Concrete Bridge Deck Connections Under Cyclic and Static Structural Loading PDF Author: Benjamin A. Graybeal
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 106

Get Book Here

Book Description
"The use of modular bridge deck components has the potential to produce higher quality, more durable bridge decks; however, the required connections have often proved lacking, resulting in less than desirable overall system performance. Advanced cementitious composite materials whose mechanical and durability properties far exceed those of conventional concretes present an opportunity to significantly enhance the performance of field-cast connections thus facilitating the wider use of modular bridge deck systems. Ultra-high performance concrete (UHPC) represents a class of such advanced cementitious composite materials. Of particular interest here, UHPCs can exhibit both exceptional bond when cast against previously cast concrete and can significantly shorten the development length of embedded discrete steel reinforcement. These properties allow for a redesign of the modular component connection, facilitating simplified construction and enhanced long-term system performance. This study investigated the structural performance of field-cast UHPC connections for modular bridge deck components. The transverse and longitudinal connection specimens simulated the connections between precast deck panels and the connections between the top flanges of deck-bulb-tee girders, respectively. Testing included both cyclic and static loadings. The results demonstrated that the field-cast UHPC connection facilitates the construction of an emulative bridge deck system whose behaviors should meet or exceed those of a conventional cast-in-place bridge deck"--Technical report documentation page.

Numerical Analysis and Experimental Investigation of Ultra-high-performance Concrete Hybrid Bridge Deck Connections

Numerical Analysis and Experimental Investigation of Ultra-high-performance Concrete Hybrid Bridge Deck Connections PDF Author: Sabreena Nasrin
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages : 284

Get Book Here

Book Description
In recent years, the use of modular bridge deck components has gained popularity for facilitating more durable components in bridge decks, but these components require field-applied connections for constructing the entire bridge. Ultra-High-Performance Concrete (UHPC) is being extensively used for highway bridges in the field connections between girders and deck panels for its superior quality than conventional concrete.Thus far, very limited data is available on the modeling of hybrid-bridge deck connections. In this study, finite element models have been developed to identify the primary properties affecting the response of hybrid deck panel system under monotonic and reverse cyclic loads. The commercial software ABAQUS was used to validate the models and to generate the data presented herein. The concrete damage plasticity (CDP) model was used to simulate both the conventional concrete and UHPC. In addition, numerical results were validated against experimental data available in the literature. The key parameters studied were the mesh size, the dilation angle, reinforcement type, concrete constitutive models, steel properties, and the contact type between the UHPC and the conventional concrete. The models were found to capture the load-deformation response, failure modes, crack patterns and ductility indices satisfactorily. The damage in concrete under monotonic loading is found higher in normal concrete than UHPC with no signs of de-bonding between the two materials. It is observed that increasing the dilation angle leads to an increase in the initial stiffness of the model. Changing the dilation angle from 20℗ʻ to 40℗ʻ results in an increase of 7.81% in ultimate load for the panel with straight reinforcing bars, whereas for the panel with headed bars, the increase in ultimate load was found 8.56 %.Furthermore, four different types of bridge deck panels were simulated under reversed cyclic loading to observe overall behavior and the damage pattern associated with the reversed cyclic load. The key parameters investigated were the configurations of steel connections between the precast concrete deck elements, the loading position, ductility index, and the failure phenomena. The headed bar connections were found to experience higher ductility than the ones with straight bars in the range of 10.12% to 30.70% in all loading conditions, which is crucial for ensuring safe structural performance. This numerical investigation provides recommendations for predicting the location of the local damage in UHPC concrete bridge deck precast panel connections under reversed cyclic loading.Despite of having excellent mechanical and material properties, the use of Ultra-High-Performance Fiber Reinforced Concrete (UHP-FRC) is not widespread due to its high cost and lack of widely accepted design guidelines. This research also aims to develop a UHPC mixture using locally and domestically available materials without heat curing in hopes of reducing the production cost. Several trial mixtures of UHPC have been developed using locally available basalt and domestically available steel fibers. Among them, one trial mixture of 20.35 ksi compressive strength was selected for further study. To investigate the applicability of this locally produced UHPC in bridge closure, two full scale-8 ft. span hybrid bridge deck slabs with UHPC closure were constructed and tested under monotonic loading to identify the structural and material responses. The load-deflection response of the hybrid connection confirms that the deflection increased linearly until the initiation of first crack, after that it increased non-linearly up to the failure of the connection. The strain response also confirms that UHPC experiences less strain than normal strength concrete under compression loading. In addition, a moment curvature analytical graphical user interface model of hybrid bridge deck connection has been developed using MATLAB to predict ductility, curvature, and the stress distributions in those connections. The predicted value of moment and curvature from the code was found in good agreement with experimental data as well. The code provides a tool to professional engineers to predict ductility, curvature, and the stress distributions in those connections. The code is built in such a way to allow various input parameters such as concrete strength, dimensions of hybrid connection and deck panels, reinforcement configuration and the shape of the connection.Though, ultra-high-performance fiber reinforced concrete (UHP-FRC) has very high compressive strength compared to conventional concrete, the failure strain of UHP-FRC is not enough to withstand large plastic deformations under high stain rate loading such as impact and blast loading. Hence, a numerical study has been conducted to simulate low-velocity impact phenomenon of UHP-FRC. The responses obtained from the numerical study are in good agreement with the experimental results under impact loads. Five different types of UHP-FRC beams were simulated under impact loading to observe the global and local material responses. The key parameters investigated were the reinforcement ratio (Ï1), impact load under various drop heights (h), and the failure phenomena. It was observed that higher reinforcement ratio showed better deflection recovery under the proposed impact. Also, for a specific reinforcement ratio, the maximum deflection increases approximately 15% when drop height decreases from 100 mm to 25 mm. Moreover, the applicability of concrete damage plasticity model for impact loading is investigated. The results also provided recommendations for predicting the location of the local damage in UHP-FRC beams under impact loading.Moreover, this research work includes a nonlinear finite element analysis of high-strength concrete confined with opposing circular spiral reinforcements. The spiral reinforcement is a very common technique used for reinforcing columns in active seismic regions due to its high ductility and high energy absorption. The results are compared with previously tested small-scale concrete columns made with the same technique under monotonic axial loads. The proposed technique is developed to improve the strength and ductility of concrete columns confined with conventional spiral systems. The finite element (FE) analysis results have shown that the proposed model can predict the failure load and crack pattern of columns with reasonable accuracy. Beside this, the concrete plasticity damage showed very good results in simulating columns with opposing spirals. The FE model is used to conduct a study on the effect of spiral spacing, Îđ (ratio of the core diameter to the whole cross section diameter) and compressive strength on the behavior of circular spiral reinforced concrete columns confined with opposing circular spiral reinforcements. The results of the parametric study demonstrated that for the same spacing between spirals and same strength of concrete, increasing Îđ increases the failure load of the column. It is also observed from the study that the ductility of the studied columns is not affected by changing the value of Îđ. In addition, a correlation between the Îđ factor, three different compressive concrete strengths, and the spacing of opposing spirals was developed in this study.

Ultra High Performance Concrete

Ultra High Performance Concrete PDF Author: Ekkehard Fehling
Publisher: kassel university press GmbH
ISBN: 3899583760
Category : High strength concrete
Languages : en
Pages : 922

Get Book Here

Book Description


Ultra-High Performance Concrete UHPC

Ultra-High Performance Concrete UHPC PDF Author: Ekkehard Fehling
Publisher: John Wiley & Sons
ISBN: 3433030871
Category : Technology & Engineering
Languages : en
Pages : 198

Get Book Here

Book Description
Selected chapters from the German concrete yearbook are now being published in the new English "Beton-Kalender Series" for the benefit of an international audience. Since it was founded in 1906, the Ernst & Sohn "Beton-Kalender" has been supporting developments in reinforced and prestressed concrete. The aim was to publish a yearbook to reflect progress in "ferro-concrete" structures until - as the book's first editor, Fritz von Emperger (1862-1942), expressed it - the "tempestuous development" in this form of construction came to an end. However, the "Beton-Kalender" quickly became the chosen work of reference for civil and structural engineers, and apart from the years 1945-1950 has been published annually ever since. Ultra high performance concrete (UHPC) is a milestone in concrete technology and application. It permits the construction of both more slender and more durable concrete structures with a prolonged service life and thus improved sustainability. This book is a comprehensive overview of UHPC - from the principles behind its production and its mechanical properties to design and detailing aspects. The focus is on the material behaviour of steel fibre-reinforced UHPC. Numerical modelling and detailing of the connections with reinforced concrete elements are featured as well. Numerous examples worldwide - bridges, columns, facades and roofs - are the basis for additional explanations about the benefits of UHPC and how it helps to realise several architectural requirements. The authors are extensively involved in the testing, design, construction and monitoring of UHPC structures. What they provide here is therefore a unique synopsis of the state of the art with a view to practical applications.

Ultra-high Performance Concrete Composite Connections for Precast Concrete Bridge Decks

Ultra-high Performance Concrete Composite Connections for Precast Concrete Bridge Decks PDF Author: Benjamin A. Graybeal
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages : 97

Get Book Here

Book Description
"The demand for accelerated construction of highway bridges and the historically sub-optimal performance of cast-in-place bridge decks has led to a demand for the use of prefabricated concrete bridge decks. Although this decking system presents many advantages, one fundamental hurdle to its use is the field-cast connections which join the panels to the supporting superstructure. The intent of this research project is to redesign the composite connection in a way that provides for simple, constructible details which do not present field fit-up issues and which provide good long-term durability performance. A relatively new construction material, ultra-high performance concrete (UHPC), was engaged for this project"--Technical report documentation page.

Ultra-high Performance Concrete Composite Connections for Precast Concrete Bridge Decks

Ultra-high Performance Concrete Composite Connections for Precast Concrete Bridge Decks PDF Author:
Publisher:
ISBN:
Category : Concrete bridges
Languages : en
Pages : 12

Get Book Here

Book Description


Behavior of Ultra-high Performance Concrete Bridge Deck Panels Compared to Conventional Stay-in-place Deck Panels

Behavior of Ultra-high Performance Concrete Bridge Deck Panels Compared to Conventional Stay-in-place Deck Panels PDF Author: Valter Gora Venancio
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 101

Get Book Here

Book Description
"The remarkable features of ultra-high performance concrete (UHPC) have been reported. Its application in bridge construction has been an active research area in recent years, attributed to its higher compressive strength, higher ductility and reduced permeability when compared with conventional concrete and even high-strength concrete. Those characteristics are known to increase bridge durability and, consequently, decrease life-cycle maintenance costs. With that in mind, this study investigated the performance of UHPC stay-in-place (SIP) bridge deck panels subjected to high loads in both flexure and shear. The test matrix consisted of twelve (12) half-scale panels that were 4 feet long and 2 feet wide. The variable parameters that were studied included thickness (i.e., 2-in. and 3-in.) as well as non-discrete reinforcement type, including conventional mild reinforcement, welded wire mesh and no reinforcement (UHPC only). Control deck panels with conventional concrete (CC) were fabricated and tested to serve as a baseline for comparison. The results indicated that the UHPC panels had an improved performance compared to the conventional concrete panels. With respect to the panels tested in high shear loads, only the CC panel test resulted in a diagonal tension failure mode (i.e. traditional shear type failure). All of the other UHPC panels failed in flexure suggesting that the UHPC provided a high shear capacity. The results also showed a good correlation with selected empirical models. A cost study was also investigated. It was concluded that, even with the high difference between the prices per cubic yard of both concretes, the difference can be significantly lower when compared with the prices per ultimate load capacity"--Abstract, page iii.

Ultra-High Performance Concrete (UHPC) Precast Segmental Bridges

Ultra-High Performance Concrete (UHPC) Precast Segmental Bridges PDF Author: Jaewoo Shin
Publisher:
ISBN: 9783844050424
Category :
Languages : en
Pages :

Get Book Here

Book Description


Fatigue Response in Bridge Deck Connection Composed of Field-Cast Ultra-High-Performance Concrete

Fatigue Response in Bridge Deck Connection Composed of Field-Cast Ultra-High-Performance Concrete PDF Author: Benjamin A. Graybeal
Publisher:
ISBN:
Category : Bridges
Languages : en
Pages : 8

Get Book Here

Book Description
The use of prefabricated concrete bridge deck components can offer many advantages over conventional cast-in-place construction techniques. However, completing the overall bridge system requires the installation of connecting elements. The state of the practice for these connecting elements has been deficient in resilience, durability, and ease of construction. An ongoing research effort at FHWA, in conjunction with partners from the New York State and Iowa Departments of Transportation, is focused on engaging the advantageous properties of ultra-high-performance concrete (UHPC) to develop a new type of detail applicable to deck-level connections between prefabricated modular bridge components. This physical testing program investigated the structural performance of a field-cast UHPC connection under repeated truck wheel loading. The connection—150 mm (5.9 in.) thick and 152 mm (6 in.) wide—was designed as a noncontact lap splice with straight 16M (No. 5) steel reinforcement. After more than 11 million structural-loading cycles at progressively increasing load levels, individual bars within the connection began to fail in metal fatigue. The stress range in the reinforcement at initial fatigue failure was conservatively estimated at 197 MPa (28.6 ksi). No debonding or slippage of reinforcement was observed. The performance of this connection detail demonstrated the types of details that can be developed and deployed with field-cast UHPC.