SVX II a Silicon Vertex Detector for Run II of the Tevatron

SVX II a Silicon Vertex Detector for Run II of the Tevatron PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 17

Get Book Here

Book Description
A microstrip silicon detector SVX II has been proposed for the upgrade of the vertex detector of the CDF experiment to be installed for run II of the Tevatron in 1998. Three barrels of four layers of double sided detectors will cover the interaction region. The requirement of the silicon tracker and the specification of the sensors are discussed together with the proposed R & D to verify the performance of the prototypes detectors produced by Sintef, Micron and Hamamatsu.

SVX II a Silicon Vertex Detector for Run II of the Tevatron

SVX II a Silicon Vertex Detector for Run II of the Tevatron PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 17

Get Book Here

Book Description
A microstrip silicon detector SVX II has been proposed for the upgrade of the vertex detector of the CDF experiment to be installed for run II of the Tevatron in 1998. Three barrels of four layers of double sided detectors will cover the interaction region. The requirement of the silicon tracker and the specification of the sensors are discussed together with the proposed R & D to verify the performance of the prototypes detectors produced by Sintef, Micron and Hamamatsu.

The SVX II Silicon Vertex Detector at CDF.

The SVX II Silicon Vertex Detector at CDF. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The Silicon Vertex detector (SVX II) for the CDF experiment at the Tevatron p{anti p} collider is a 3-barrel 5-layer device with double-sided, AC-coupled silicon strip detectors. The readout is based on a custom IC, the SVX3 chip, capable of simultaneous acquisition, digitization and readout operation (dead-timeless). In this paper we report on the SVX II design and project status including mechanical design, frontend electronics, and data acquisition.

The CDF SVX II Detector Upgrade

The CDF SVX II Detector Upgrade PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 8

Get Book Here

Book Description
The proposed CDF SVX II detector upgrade for secondary vertex detection during the Fermilab Tevatron Run II collider run is described. The general design and important features of this silicon vertex detector are presented. The CDF physics goals which are addressed by this detector are also given.

The CDF Silicon Vertex Detector SVX and Its Upgrades

The CDF Silicon Vertex Detector SVX and Its Upgrades PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 16

Get Book Here

Book Description


Data Acquisition for the CDF SVX II Upgrade

Data Acquisition for the CDF SVX II Upgrade PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Get Book Here

Book Description
CDF is developing a second generation silicon vertex detector for the Fermilab Tevatron Run II. In order to exploit the high luminosity of the Fermilab Main Injector, the data acquisition system is being designed to accept high trigger rates and accommodate a secondary vertex trigger.

Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector

Double-sided Silicon Microstrip Sensors for the CDF SVX II Detector PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Get Book Here

Book Description
The SVX II is the planned third-generation silicon vertex detector in the Collider Detector at Fermilab. Now in the prototyping phase, it is scheduled for operation in Tevatron Run II. This document describes aspects of the detector related to the design of the silicon microstrip sensors.

Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications

Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications PDF Author:
Publisher: World Scientific
ISBN: 9812819096
Category : Science
Languages : en
Pages : 1063

Get Book Here

Book Description
The exploration of the subnuclear world is done through increasingly complex experiments covering a wide range of energies and in a large variety of environments OCo from particle accelerators and underground detectors to satellites and space laboratories. For these research programs to succeed, novel techniques, new materials and new instrumentation need to be used in detectors, often on a large scale. Hence, particle physics is at the forefront of technological advancement and leads to numerous applications. Among these, medical applications have a particular importance due to the health and social benefits they bring. This volume reviews the advances made in all technological aspects of current experiments in the field."

Operation and Performance of the Silicon Vertex Detector (SVX') at CDF.

Operation and Performance of the Silicon Vertex Detector (SVX') at CDF. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
The authors describe the operation and performance of the Silicon Vertex Detector (SVX'), which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX' include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb[sup -1] of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12 [mu]m. This provides a powerful tool to do top and bottom physics.

Operation and Performance of the Silicon Vertex Detector (SVX)̀ at CDF.

Operation and Performance of the Silicon Vertex Detector (SVX)̀ at CDF. PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 7

Get Book Here

Book Description
The authors describe the operation and performance of the Silicon Vertex Detector (SVX)̀, which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX ̀include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb−1 of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12?m. This provides a powerful tool to do top and bottom physics.

Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 538

Get Book Here

Book Description
Lists citations with abstracts for aerospace related reports obtained from world wide sources and announces documents that have recently been entered into the NASA Scientific and Technical Information Database.