Author: Nicholas Edward Peter Fernandez
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Performance and Oil Retention Characteristics of a CO2 Heat Pump Water Heater
Author: Nicholas Edward Peter Fernandez
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Transcritical CO2 Heat Pump
Author: Xin-rong Zhang
Publisher: John Wiley & Sons
ISBN: 1118380045
Category : Science
Languages : en
Pages : 320
Book Description
A timely and comprehensive introduction to CO2 heat pump theory and usage A comprehensive introduction of CO2 application in heat pump, authored by leading scientists in the field CO2 is a hot topic due to concerns over global warming and the 'greenhouse effect'. Its disposal and application has attracted considerable research and governmental interest Explores the basic theories, devices, systems and cycles and real application designs for varying applications, ensuring comprehensive coverage of a current topic CO2 heat transfer has everyday applications including water heaters, air-conditioning systems, residential and commercial heating systems, and cooling systems
Publisher: John Wiley & Sons
ISBN: 1118380045
Category : Science
Languages : en
Pages : 320
Book Description
A timely and comprehensive introduction to CO2 heat pump theory and usage A comprehensive introduction of CO2 application in heat pump, authored by leading scientists in the field CO2 is a hot topic due to concerns over global warming and the 'greenhouse effect'. Its disposal and application has attracted considerable research and governmental interest Explores the basic theories, devices, systems and cycles and real application designs for varying applications, ensuring comprehensive coverage of a current topic CO2 heat transfer has everyday applications including water heaters, air-conditioning systems, residential and commercial heating systems, and cooling systems
Performance Characteristics of a Heat Pump Water Heater
Author: Thanh Thanh Phan
Publisher:
ISBN:
Category : Heat pumps
Languages : en
Pages : 138
Book Description
Publisher:
ISBN:
Category : Heat pumps
Languages : en
Pages : 138
Book Description
Reliable, Economic, Efficient CO2 Heat Pump Water Heater for North America
Author: Young Park
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Adoption of heat pump water heating technology for commercial hot water could save up to 0.4 quads of energy and 5 million metric tons of CO2 production annually in North America, but industry perception is that this technology does not offer adequate performance or reliability and comes at too high of a cost. Development and demonstration of a CO2 heat pump water heater is proposed to reduce these barriers to adoption. Three major themes are addressed: market analysis to understand barriers to adoption, use of advanced reliability models to design optimum qualification test plans, and field testing of two phases of water heater prototypes. Market experts claim that beyond good performance, market adoption requires 'drop and forget' system reliability and a six month payback of first costs. Performance, reliability and cost targets are determined and reliability models are developed to evaluate the minimum testing required to meet reliability targets. Three phase 1 prototypes are designed and installed in the field. Based on results from these trials a product specification is developed and a second phase of five field trial units are built and installed. These eight units accumulate 11 unit-years of service including 15,650 hours and 25,242 cycles of compressor operation. Performance targets can be met. An availability of 60% is achieved and the capability to achieve>90% is demonstrated, but overall reliability is below target, with an average of 3.6 failures/unit-year on the phase 2 demonstration. Most reliability issues are shown to be common to new HVAC products, giving high confidence in mature product reliability, but the need for further work to minimize leaks and ensure reliability of the electronic expansion valve is clear. First cost is projected to be above target, leading to an expectation of 8-24 month payback when substituted for an electric water heater. Despite not meeting all targets, arguments are made that an industry leader could sufficiently develop this technology to impact the water heater market in the near term.
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Adoption of heat pump water heating technology for commercial hot water could save up to 0.4 quads of energy and 5 million metric tons of CO2 production annually in North America, but industry perception is that this technology does not offer adequate performance or reliability and comes at too high of a cost. Development and demonstration of a CO2 heat pump water heater is proposed to reduce these barriers to adoption. Three major themes are addressed: market analysis to understand barriers to adoption, use of advanced reliability models to design optimum qualification test plans, and field testing of two phases of water heater prototypes. Market experts claim that beyond good performance, market adoption requires 'drop and forget' system reliability and a six month payback of first costs. Performance, reliability and cost targets are determined and reliability models are developed to evaluate the minimum testing required to meet reliability targets. Three phase 1 prototypes are designed and installed in the field. Based on results from these trials a product specification is developed and a second phase of five field trial units are built and installed. These eight units accumulate 11 unit-years of service including 15,650 hours and 25,242 cycles of compressor operation. Performance targets can be met. An availability of 60% is achieved and the capability to achieve>90% is demonstrated, but overall reliability is below target, with an average of 3.6 failures/unit-year on the phase 2 demonstration. Most reliability issues are shown to be common to new HVAC products, giving high confidence in mature product reliability, but the need for further work to minimize leaks and ensure reliability of the electronic expansion valve is clear. First cost is projected to be above target, leading to an expectation of 8-24 month payback when substituted for an electric water heater. Despite not meeting all targets, arguments are made that an industry leader could sufficiently develop this technology to impact the water heater market in the near term.
Performance Characteristics of Oil-fires Water Heaters
Author: Robert F. Grier
Publisher:
ISBN:
Category : Water heaters
Languages : en
Pages : 13
Book Description
Publisher:
ISBN:
Category : Water heaters
Languages : en
Pages : 13
Book Description
Improvements on Performance of a Heat Pump Water Heater System
Author: Ce Shi
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Publisher:
ISBN:
Category :
Languages : en
Pages :
Book Description
Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-Cooler
Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 384
Book Description
This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queen's University in the Solar Calorimetry Laboratory. Due to the predicted high heat rejection temperatures in a transcritical vapour-compression cycle, buoyancy driven thermosyphon flow through a brazed-plate gas-cooler was proposed to promote tank stratification and to improve system performance. The performance was evaluated through a series of experimental sensitivity and static tank charge tests. A TRNSYS model was also created and verified to simulate the performance of the system under a detailed user demand schedule for a week of operation. The TRNSYS model used a parametric table created with a steady-state model of the vapour-compression system in EES that was validated against experimental data to a standard error of the Y-estimate of ±0.073 kW for heating capacity, ±1.01°C for gas-cooler exit temperature, and ±0.086 for COP. A series of tank charge tests were conducted under thermosyphon flow and forced flow rates at 1 L/min, 2 L/min, and 4 L/min. The thermosyphon charge test produced the highest level of stratification and a total COP of 3 at an average flow rate of 0.73 L/min. All of the forced convection cases operated with a higher degree of mixing. TRNSYS model simulations with hot water draws found that the thermosyphon flow configuration performed with a higher degree of stratification under regular user demand while simulations with high flow rates resulted in a mixed tank at a high temperature. Results predicted an 11% reduction in required heat energy input to the storage, a 30% reduction in electrical energy consumption, a 35% reduction in heat loss, and a 29% improvement in COP for the thermosyphon test as compared to the operation with a mixed tank at 4 L/min. The thermosyphon draw test also performed with the lowest average tank temperature, yet produced the highest draw temperatures. Through these results, it was concluded that natural convection operation with brazed-plate gas-coolers can contribute to a better performing system and this flow configuration should be considered in future applications of this technology.
Publisher:
ISBN:
Category :
Languages : en
Pages : 384
Book Description
This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queen's University in the Solar Calorimetry Laboratory. Due to the predicted high heat rejection temperatures in a transcritical vapour-compression cycle, buoyancy driven thermosyphon flow through a brazed-plate gas-cooler was proposed to promote tank stratification and to improve system performance. The performance was evaluated through a series of experimental sensitivity and static tank charge tests. A TRNSYS model was also created and verified to simulate the performance of the system under a detailed user demand schedule for a week of operation. The TRNSYS model used a parametric table created with a steady-state model of the vapour-compression system in EES that was validated against experimental data to a standard error of the Y-estimate of ±0.073 kW for heating capacity, ±1.01°C for gas-cooler exit temperature, and ±0.086 for COP. A series of tank charge tests were conducted under thermosyphon flow and forced flow rates at 1 L/min, 2 L/min, and 4 L/min. The thermosyphon charge test produced the highest level of stratification and a total COP of 3 at an average flow rate of 0.73 L/min. All of the forced convection cases operated with a higher degree of mixing. TRNSYS model simulations with hot water draws found that the thermosyphon flow configuration performed with a higher degree of stratification under regular user demand while simulations with high flow rates resulted in a mixed tank at a high temperature. Results predicted an 11% reduction in required heat energy input to the storage, a 30% reduction in electrical energy consumption, a 35% reduction in heat loss, and a 29% improvement in COP for the thermosyphon test as compared to the operation with a mixed tank at 4 L/min. The thermosyphon draw test also performed with the lowest average tank temperature, yet produced the highest draw temperatures. Through these results, it was concluded that natural convection operation with brazed-plate gas-coolers can contribute to a better performing system and this flow configuration should be considered in future applications of this technology.
Performance of a Heat Pump Water Heater
Author: Estel B. Penrod
Publisher:
ISBN:
Category : Heat pumps
Languages : en
Pages : 39
Book Description
Publisher:
ISBN:
Category : Heat pumps
Languages : en
Pages : 39
Book Description
Heat Pump Water Heaters
Author: Standards Australia (Organization)
Publisher:
ISBN: 9781775514657
Category :
Languages : en
Pages :
Book Description
Publisher:
ISBN: 9781775514657
Category :
Languages : en
Pages :
Book Description
8th IIR Gustav Lorentzen Conference on Natural Working Fluids, September 7-10, 2008, Copenhagen, Denmark
Author:
Publisher:
ISBN: 9782913149632
Category : Refrigerants
Languages : en
Pages : 112
Book Description
Publisher:
ISBN: 9782913149632
Category : Refrigerants
Languages : en
Pages : 112
Book Description