Finite Element Stress Analysis of Bone Surrounding Osseointegrated Dental Implants

Finite Element Stress Analysis of Bone Surrounding Osseointegrated Dental Implants PDF Author: Marianne Ierace Mayberry
Publisher:
ISBN:
Category : Dental implants
Languages : en
Pages : 130

Get Book Here

Book Description

Finite Element Stress Analysis of Bone Surrounding Osseointegrated Dental Implants

Finite Element Stress Analysis of Bone Surrounding Osseointegrated Dental Implants PDF Author: Marianne Ierace Mayberry
Publisher:
ISBN:
Category : Dental implants
Languages : en
Pages : 130

Get Book Here

Book Description


Application of the Finite Element Method in Implant Dentistry

Application of the Finite Element Method in Implant Dentistry PDF Author: Jianping Geng
Publisher: Springer Science & Business Media
ISBN: 3540737642
Category : Technology & Engineering
Languages : en
Pages : 148

Get Book Here

Book Description
This book creates the theoretical foundation that novices need to perform the finite element method in implant dentistry. It shows how both the implant dentist and the designer can benefit from finite element analysis. The authors explain the theory and math of the finite element method. Then, you get practical applications alongside discussions of the critical issues in using finite element analysis for dental implant design.

Stress Analysis on the Bone Around Five Different Dental Implants

Stress Analysis on the Bone Around Five Different Dental Implants PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages : 0

Get Book Here

Book Description
Implantology has a widespread application in dental cases these days. Although the life of this practice is short, there has been considerable progress in this field and many research laboratories and production sites have been developed in this regard. There are various types of implants in the market, and there is a need to study their features to find out the advantages and disadvantages of them and choose the appropriate implant in each case. One major research is the study of stress distribution on the bone around the implant, which is an effective criterion in osseointegration. In this paper, stress analysis has been conducted on the bone by applying finite element method. A comparison has been performed among different models of dental implant fixtures.

Finite Element Analysis of Stress Induced Fractures in Bone Around Dental Implants

Finite Element Analysis of Stress Induced Fractures in Bone Around Dental Implants PDF Author: George A. Papavasiliou
Publisher:
ISBN:
Category : Dissertations, Academic
Languages : en
Pages : 232

Get Book Here

Book Description


A Finite Element Analysis of the Stress Distribution of an Osseointegrated Implant

A Finite Element Analysis of the Stress Distribution of an Osseointegrated Implant PDF Author: Aisling M. O'Mahony
Publisher:
ISBN:
Category :
Languages : en
Pages : 386

Get Book Here

Book Description
The maintenance of the osseointegrated implant bone interface is critical to the success of the osseointegrated implant. Many clinical studies have suggested that repeatedly excessive loads applied to the implant restoration, is one of the factors contributing to breakdown at the implant/bone interface and premature failures of the osseointegrated implant. In the single unit osseointegrated implant in the posterior mandible the mesiodistal and buccolingual widths of the crown are generally greater than the width of the implant fixture. The point of load application is one of the variables that influences the manner in which occlusal forces are transmitted to the implant and surrounding bone. Off axis loads applied to the crown create a cantilever effect and introduce bending moments which may cause excessive stresses at the implant bone interface. The wider the crown, the greater the potential for off axis loading. The purpose of this study was to evaluate and compare the effect of axial and off axis loads on the stress gradients at the oxxeointegrated implant/bone interface of a single unit posterior implant. Finite element analysis was used to evaluate the magnitude and location of stresses. Occlusal forces were modeled as axial and off axis vertical loading. The study showed that under load conditions the highest stresses were concentrated at the apex of the implant and at the crestal bone/implant interface. Off axis loading resulted in a large increase in compressive stresses in the crestal cortical bone on the side of the applied load, and a large increase in tensile stresses in the crestal cortical bone on the side opposite the applied load.

Bone Implant Interface

Bone Implant Interface PDF Author: Hugh U. Cameron
Publisher: St. Louis ; Toronto : Moseby
ISBN:
Category : Medical
Languages : en
Pages : 408

Get Book Here

Book Description


Structural Analysis of an Osseointegrated Dental Implant System

Structural Analysis of an Osseointegrated Dental Implant System PDF Author: M. Jane Morgan
Publisher: National Library of Canada = Bibliothèque nationale du Canada
ISBN:
Category : Osseointegrated dental implants
Languages : en
Pages : 406

Get Book Here

Book Description


Finite Element Analysis of Dental Implant-bone System During and After Implantation

Finite Element Analysis of Dental Implant-bone System During and After Implantation PDF Author: Rudi Cobus Van Staden
Publisher:
ISBN:
Category : Dental implants
Languages : en
Pages :

Get Book Here

Book Description
Abstract : Development of an ideal substitute for missing teeth has been a major aim of dental practitioners for millennia. Modern dental implants are biocompatible screw-like titanium {u2018}fixtures{u2019} that are surgically placed into the jaws to replace missing teeth. Implants are superior to conventional prostheses, in both function and long-term predictability. In 2006 approximately 30,000 implants were placed in Australian patients. Implant sales have doubled in the last 5 years and are increasing by about 15% per year. Although implants exhibit excellent long-term retention (~95% after 5 years), there are significantly more failures in areas where bone quality and quantity is poor, resulting in poor patient outcomes and costs estimated at $15 million per year in Australia. Most failures arise from poor clinical technique and inadequate understanding of the potentially damaging stress characteristics during implant placement and function (chewing). Three-dimensional (3D) Finite Element Analysis (FEA) is a numerical method for analysing stresses and deformations in structures of any given geometry and under any load. There are reports on utilising 3D FEA to investigate implant-jawbone interactions after full osseointegration. However no work has been done to comprehensively quantify the performance of the bone-implant system during and after implantation. This research thus aims to develop a comprehensive FEA technique to evaluate the performance of the bone-implant system during the implantation process itself, as well as the healing and maintenance phases of osseointegration.

Finite Element Analysis of the Stress on the Implant-Bone Interface of Dental Implants with Different Structures

Finite Element Analysis of the Stress on the Implant-Bone Interface of Dental Implants with Different Structures PDF Author: Liangjian Chen
Publisher:
ISBN:
Category : Technology
Languages : en
Pages :

Get Book Here

Book Description
Finite Element Analysis of the Stress on the Implant-Bone Interface of Dental Implants with Different Structures.

Finite Element Analysis of Bone Remodeling Around Porous-coated Dental Implants [microform]

Finite Element Analysis of Bone Remodeling Around Porous-coated Dental Implants [microform] PDF Author: Hélène Vaillancourt
Publisher: National Library of Canada = Bibliothèque nationale du Canada
ISBN: 9780315928350
Category :
Languages : en
Pages : 372

Get Book Here

Book Description