Evaluation of Pre-extraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water

Evaluation of Pre-extraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category : Nitroamines
Languages : en
Pages : 24

Get Book Here

Book Description

Evaluation of Pre-extraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water

Evaluation of Pre-extraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category : Nitroamines
Languages : en
Pages : 24

Get Book Here

Book Description


Evaluation of Pre-extraction Analytical Holding Times for Nitoaromatic and Nitramine Explosives in Water

Evaluation of Pre-extraction Analytical Holding Times for Nitoaromatic and Nitramine Explosives in Water PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category :
Languages : en
Pages : 13

Get Book Here

Book Description


Evaluation of Pre-extaraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water

Evaluation of Pre-extaraction Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Water PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category : Nitroamines
Languages : en
Pages : 13

Get Book Here

Book Description


Experimental Assessment of Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Soil

Experimental Assessment of Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Soil PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 28

Get Book Here

Book Description


On-site Method for Measuring Nitroaromatic and Nitramine Explosives in Soil and Groundwater Using GC-NPD

On-site Method for Measuring Nitroaromatic and Nitramine Explosives in Soil and Groundwater Using GC-NPD PDF Author: Alan Dole Hewitt
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 24

Get Book Here

Book Description


Preservation of Water Samples Containing Nitroaromatics and Nitramines

Preservation of Water Samples Containing Nitroaromatics and Nitramines PDF Author:
Publisher: DIANE Publishing
ISBN: 1428914552
Category :
Languages : en
Pages : 36

Get Book Here

Book Description


Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC

Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Water Using SPE and GC-ECD Comparison with HPLC PDF Author: Marianne E. Walsh
Publisher:
ISBN:
Category : Explosives, Military
Languages : en
Pages : 74

Get Book Here

Book Description
An analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.

Experimental Assessment of Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Soil

Experimental Assessment of Analytical Holding Times for Nitroaromatic and Nitramine Explosives in Soil PDF Author: Clarence L. Grant
Publisher:
ISBN:
Category : Explosives
Languages : en
Pages : 18

Get Book Here

Book Description


Special Report

Special Report PDF Author:
Publisher:
ISBN:
Category : Arctic regions
Languages : en
Pages : 16

Get Book Here

Book Description


Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 804

Get Book Here

Book Description
Lists citations with abstracts for aerospace related reports obtained from world wide sources and announces documents that have recently been entered into the NASA Scientific and Technical Information Database.