CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE

CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE PDF Author: PHILIPPE.. KUNTZ
Publisher:
ISBN:
Category :
Languages : fr
Pages : 223

Get Book Here

Book Description
AVEC LA RECENTE LOI SUR L'EAU DE JANVIER 1992 QUI COMPORTE UNE NECESSITE DE TRAITEMENTS DES EAUX RESIDUAIRES TOUJOURS PLUS POUSSES, DONC DELICATS A GERER, IL DEVIENT INDISPENSABLE D'ACCEDER A UNE MEILLEURE CONNAISSANCE DES FLUX DE POLLUTION, NOTAMMENT AZOTEE. OR, LA MESURE EN CONTINU ET SUR SITE DES NITRATES (NO 3) N'EST PAS ENCORE SUFFISAMMENT FIABLE OU EST TROP COMPLEXE ET COUTEUSE. POUR TENTER DE REMEDIER A CETTE SITUATION, NOUS AVONS ETUDIE UN PRINCIPE DE MESURE SIMPLE ET RELATIVEMENT SELECTIF : L'ABSORPTION DIRECTE DU RAYONNEMENT ULTRAVIOLET PAR LES IONS NITRATES. UNE ETUDE DE FAISABILITE AVEC UN SPECTROPHOTOMETRE DE LABORATOIRE, SUR DES ECHANTILLONS REELS, NOUS A PERMIS D'OBTENIR UN MODELE SIMPLE DE CALCUL DES CONCENTRATIONS EN NITRATES, APPLICABLE AUX EAUX USEES DE REJET PROVENANT DE DIFFERENTS TYPES DE TRAITEMENTS, MAIS AUSSI A DES EAUX SUPERFICIELLES OU DE NAPPE. CE MODELE UNIVERSEL (INDEPENDANT DU SITE) TIENT COMPTE DE CERTAINS INTERFERENTS DANS DES GAMMES DE CONCENTRATIONS SUSCEPTIBLES D'Y ETRE RENCONTREES. LA MESURE DES MATIERES EN SUSPENSION ET DES MATIERES ORGANIQUES A ETE PRISE EN COMPTE, RENDANT POSSIBLE LA REALISATION D'UN CAPTEUR MULTIPARAMETRE. LA LONGUEUR DU TRAJET OPTIQUE RETENUE PERMET D'OBTENIR UNE BONNE LINEARITE SUR LA GAMME 0-150 MG/L NO 3 ET UNE PRECISION SUR EFFLUENTS TRAITES DE L'ORDRE DE 3 MG/L (NIVEAU DE CONFIANCE A 95%). D'AUTRE PART, AUCUNE FILTRATION DE L'EFFLUENT N'EST NECESSAIRE POUR DES CONCENTRATIONS EN MATIERES EN SUSPENSION ALLANT JUSQU'A 300 MG/L, ET UN SYSTEME DE NETTOYAGE PAR RACLAGE DEVRAIT ETRE ADAPTABLE AUX DIMENSIONS DE LA CELLULE DE MESURE. CETTE ETUDE S'EST POURSUIVIE PAR LA REALISATION D'UNE MAQUETTE, PREFIGURANT UN PROTOTYPE POUR SA PARTIE OPTIQUE : SOURCE DEUTERIUM, FIBRES OPTIQUES ET SPECTROPHOTOMETRE MONOLITHIQUE A BARRETTE DE PHOTODIODES. LES PREMIERS RESULTATS SONT TRES ENCOURAGEANTS PUISQU'ILS CONFIRMENT LA FAISABILITE DE LA MESURE DES NITRATES, MAIS AUSSI DE L'UTILISATION DES FIBRES OPTIQUES. CE DERNIER POINT N'EST RENDU POSSIBLE QUE PAR L'EMPLOI DE LONGUEURS D'ONDE SUPERIEURES A 220 NM, LIMITE DE LEUR TRANSMISSION DANS L'ULTRAVIOLET.

CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE

CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE PDF Author: PHILIPPE.. KUNTZ
Publisher:
ISBN:
Category :
Languages : fr
Pages : 223

Get Book Here

Book Description
AVEC LA RECENTE LOI SUR L'EAU DE JANVIER 1992 QUI COMPORTE UNE NECESSITE DE TRAITEMENTS DES EAUX RESIDUAIRES TOUJOURS PLUS POUSSES, DONC DELICATS A GERER, IL DEVIENT INDISPENSABLE D'ACCEDER A UNE MEILLEURE CONNAISSANCE DES FLUX DE POLLUTION, NOTAMMENT AZOTEE. OR, LA MESURE EN CONTINU ET SUR SITE DES NITRATES (NO 3) N'EST PAS ENCORE SUFFISAMMENT FIABLE OU EST TROP COMPLEXE ET COUTEUSE. POUR TENTER DE REMEDIER A CETTE SITUATION, NOUS AVONS ETUDIE UN PRINCIPE DE MESURE SIMPLE ET RELATIVEMENT SELECTIF : L'ABSORPTION DIRECTE DU RAYONNEMENT ULTRAVIOLET PAR LES IONS NITRATES. UNE ETUDE DE FAISABILITE AVEC UN SPECTROPHOTOMETRE DE LABORATOIRE, SUR DES ECHANTILLONS REELS, NOUS A PERMIS D'OBTENIR UN MODELE SIMPLE DE CALCUL DES CONCENTRATIONS EN NITRATES, APPLICABLE AUX EAUX USEES DE REJET PROVENANT DE DIFFERENTS TYPES DE TRAITEMENTS, MAIS AUSSI A DES EAUX SUPERFICIELLES OU DE NAPPE. CE MODELE UNIVERSEL (INDEPENDANT DU SITE) TIENT COMPTE DE CERTAINS INTERFERENTS DANS DES GAMMES DE CONCENTRATIONS SUSCEPTIBLES D'Y ETRE RENCONTREES. LA MESURE DES MATIERES EN SUSPENSION ET DES MATIERES ORGANIQUES A ETE PRISE EN COMPTE, RENDANT POSSIBLE LA REALISATION D'UN CAPTEUR MULTIPARAMETRE. LA LONGUEUR DU TRAJET OPTIQUE RETENUE PERMET D'OBTENIR UNE BONNE LINEARITE SUR LA GAMME 0-150 MG/L NO 3 ET UNE PRECISION SUR EFFLUENTS TRAITES DE L'ORDRE DE 3 MG/L (NIVEAU DE CONFIANCE A 95%). D'AUTRE PART, AUCUNE FILTRATION DE L'EFFLUENT N'EST NECESSAIRE POUR DES CONCENTRATIONS EN MATIERES EN SUSPENSION ALLANT JUSQU'A 300 MG/L, ET UN SYSTEME DE NETTOYAGE PAR RACLAGE DEVRAIT ETRE ADAPTABLE AUX DIMENSIONS DE LA CELLULE DE MESURE. CETTE ETUDE S'EST POURSUIVIE PAR LA REALISATION D'UNE MAQUETTE, PREFIGURANT UN PROTOTYPE POUR SA PARTIE OPTIQUE : SOURCE DEUTERIUM, FIBRES OPTIQUES ET SPECTROPHOTOMETRE MONOLITHIQUE A BARRETTE DE PHOTODIODES. LES PREMIERS RESULTATS SONT TRES ENCOURAGEANTS PUISQU'ILS CONFIRMENT LA FAISABILITE DE LA MESURE DES NITRATES, MAIS AUSSI DE L'UTILISATION DES FIBRES OPTIQUES. CE DERNIER POINT N'EST RENDU POSSIBLE QUE PAR L'EMPLOI DE LONGUEURS D'ONDE SUPERIEURES A 220 NM, LIMITE DE LEUR TRANSMISSION DANS L'ULTRAVIOLET.

CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE

CONCEPTION D'UN SYSTEME DE MESURE EN CONTINU DES NITRATES, DES MATIERES ORGANIQUES ET DES MATIERES EN SUSPENSION DANS LES EAUX RESIDUAIRES, TRAITEES PAR SPECTROPHOTOMETRIE D'ABSORPTION DANS L'ULTRAVIOLET ET LE VISIBLE PDF Author: PHILIPPE.. KUNTZ
Publisher:
ISBN:
Category :
Languages : fr
Pages :

Get Book Here

Book Description
AVEC LA RECENTE LOI SUR L'EAU DE JANVIER 1992 QUI COMPORTE UNE NECESSITE DE TRAITEMENTS DES EAUX RESIDUAIRES TOUJOURS PLUS POUSSES, DONC DELICATS A GERER, IL DEVIENT INDISPENSABLE D'ACCEDER A UNE MEILLEURE CONNAISSANCE DES FLUX DE POLLUTION, NOTAMMENT AZOTEE. OR, LA MESURE EN CONTINU ET SUR SITE DES NITRATES (NO 3) N'EST PAS ENCORE SUFFISAMMENT FIABLE OU EST TROP COMPLEXE ET COUTEUSE. POUR TENTER DE REMEDIER A CETTE SITUATION, NOUS AVONS ETUDIE UN PRINCIPE DE MESURE SIMPLE ET RELATIVEMENT SELECTIF : L'ABSORPTION DIRECTE DU RAYONNEMENT ULTRAVIOLET PAR LES IONS NITRATES. UNE ETUDE DE FAISABILITE AVEC UN SPECTROPHOTOMETRE DE LABORATOIRE, SUR DES ECHANTILLONS REELS, NOUS A PERMIS D'OBTENIR UN MODELE SIMPLE DE CALCUL DES CONCENTRATIONS EN NITRATES, APPLICABLE AUX EAUX USEES DE REJET PROVENANT DE DIFFERENTS TYPES DE TRAITEMENTS, MAIS AUSSI A DES EAUX SUPERFICIELLES OU DE NAPPE. CE MODELE UNIVERSEL (INDEPENDANT DU SITE) TIENT COMPTE DE CERTAINS INTERFERENTS DANS DES GAMMES DE CONCENTRATIONS SUSCEPTIBLES D'Y ETRE RENCONTREES. LA MESURE DES MATIERES EN SUSPENSION ET DES MATIERES ORGANIQUES A ETE PRISE EN COMPTE, RENDANT POSSIBLE LA REALISATION D'UN CAPTEUR MULTIPARAMETRE. LA LONGUEUR DU TRAJET OPTIQUE RETENUE PERMET D'OBTENIR UNE BONNE LINEARITE SUR LA GAMME 0-150 MG/L NO 3 ET UNE PRECISION SUR EFFLUENTS TRAITES DE L'ORDRE DE 3 MG/L (NIVEAU DE CONFIANCE A 95%). D'AUTRE PART, AUCUNE FILTRATION DE L'EFFLUENT N'EST NECESSAIRE POUR DES CONCENTRATIONS EN MATIERES EN SUSPENSION ALLANT JUSQU'A 300 MG/L, ET UN SYSTEME DE NETTOYAGE PAR RACLAGE DEVRAIT ETRE ADAPTABLE AUX DIMENSIONS DE LA CELLULE DE MESURE. CETTE ETUDE S'EST POURSUIVIE PAR LA REALISATION D'UNE MAQUETTE, PREFIGURANT UN PROTOTYPE POUR SA PARTIE OPTIQUE : SOURCE DEUTERIUM, FIBRES OPTIQUES ET SPECTROPHOTOMETRE MONOLITHIQUE A BARRETTE DE PHOTODIODES. LES PREMIERS RESULTATS SONT TRES ENCOURAGEANTS PUISQU'ILS CONFIRMENT LA FAISABILITE DE LA MESURE DES NITRATES, MAIS AUSSI DE L'UTILISATION DES FIBRES OPTIQUES. CE DERNIER POINT N'EST RENDU POSSIBLE QUE PAR L'EMPLOI DE LONGUEURS D'ONDE SUPERIEURES A 220 NM, LIMITE DE LEUR TRANSMISSION DANS L'ULTRAVIOLET.

Contribution à la réalisation d'un appareil de mesure en continu et in-situ du taux de Matières En Suspension dans les systèmes d'eau et d'assainissement

Contribution à la réalisation d'un appareil de mesure en continu et in-situ du taux de Matières En Suspension dans les systèmes d'eau et d'assainissement PDF Author: Jérôme Mathieu
Publisher:
ISBN:
Category :
Languages : fr
Pages : 234

Get Book Here

Book Description
LE CONTROLE DE LA POLLUTION, NOTAMMENT DANS LES SYSTEMES D'EAU ET D'ASSAINISSEMENT, NECESSITE LA MESURE DE PARAMETRES SPECIFIQUES. LE TAUX DE MATIERES EN SUSPENSION (MES) FAIT PARTIE DE CES PARAMETRES. OR LES APPAREILS EXISTANTS DE MESURE EN CONTINU ET IN SITU DU TAUX DE MES NE SATISFONT PAS AUX PRINCIPALES EXIGENCES METROLOGIQUES, ET PARTICULIEREMENT LA FIABILITE. C'EST L'OBJECTIF DE CETTE THESE QUE DE PROPOSER UNE NOUVELLE METHODE DE MESURE FIABLE. L'ETUDE EST CONDUITE EN TROIS TEMPS. LE PREMIER CONSISTE A RECENSER LES DONNEES DISPONIBLES SUR LES MES ET A ETUDIER LES METHODES ACTUELLES DE MESURE DE SON TAUX. CETTE ETAPE SE CONCLUT PAR LA PROPOSITION D'UN CAHIER DES CHARGES POUR L'ELABORATION D'UN MES-METRE IDEAL. EN SECOND LIEU, ON ANALYSE UN ENSEMBLE DE METHODES EXISTANTES POUVANT TOTALEMENT OU PARTIELLEMENT REPONDRE AU CAHIER DES CHARGES. LES FORCES ET LES FAIBLESSES DE CHACUNE D'ELLES NOUS PERMETTENT DE PROPOSER UNE SOLUTION COMPLETE, REPOSANT SUR UN GRANULOMETRE ULTRASONORE CONCU PAR NOS SOINS ET BAPTISE GRANULOMETRE PAR RETRO-DIFFUSION QUASI-RIGIDE ULTRASONORE (GREDQRU). DANS UN TROISIEME TEMPS, ON DECRIT ET ETUDIE LA FAISABILITE (AVEC DES FILS) DU GRANULOMETRE GREDQRU. SON PRINCIPE SE BASE SUR L'ANALYSE DES ECHOS ULTRASONORES RETRODIFFUSES PAR LES CIBLES (PARTICULES SPHERIQUES OU FILS) SUIVANT LA THEORIE DE LA DIFFUSION RESONANTE TDR. EN PARTICULIER, NOUS RECUEILLONS L'ONDE SPECULAIRE ET L'ONDE DE SCHOLTE-STONELEY POUR FORMER CE QU'ON APPELLE L'ECHO QUASI-RIGIDE. CET ECHO A LA PARTICULARITE ESSENTIELLE POUR UN MES-METRE DE COMPORTER L'INFORMATION TAILLE ET D'ETRE PEU SENSIBLE A LA NATURE DU MATERIAU CONSTITUANT L'OBSTACLE DIFFUSANT. LA TAILLE EST OBTENUE EN COMPARANT CHAQUE SPECTRE D'ECHO QUASI-RIGIDE A UNE FONCTION DE REFERENCE : LA FONCTION DE FORME QUASI-RIGIDE. LES DIFFERENTS FACTEURS SUSCEPTIBLES DE PERTURBER LA MESURE (NON-LINEARITE, ATTENUATION, DIRECTIVITE DES TRANSDUCTEURS) SONT EGALEMENT ETUDIES. L'ETUDE S'ACHEVE PAR LA SPECIFICATION ELECTRONIQUE DES COMPOSANTS DU MES-METRE.