Streaming of 14-MeV Neutrons Through an Iron Duct

Streaming of 14-MeV Neutrons Through an Iron Duct PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Neutron and gamma-ray energy spectra resulting from the streaming of 14 MeV neutrons through a 0.30-m-diameter duct (length-to-diameter ratio = 2.83) have been calculated using the Monte Carlo code MCNP. The calculated spectra are compared with measured data and data calculated previously using a combination of discrete ordinates and Monte Carlo methods. Comparisons are made at twelve detector locations on and off the duct axis for neutrons with energies above 850 keV and for gamma rays with energies above 750 keV. The neutron spectra calculated using MCNP agree with the measured data within approx. 5 to approx. 50%, depending on detector location and neutron energy. Agreement with the measured gamma-ray spectra is also within approx. 5 to approx. 50%. The spectra obtained with MCNP are also in favorable agreement with the previously calculated data and were obtained with less calculational effort.

Streaming of 14-MeV Neutrons Through an Iron Duct

Streaming of 14-MeV Neutrons Through an Iron Duct PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Neutron and gamma-ray energy spectra resulting from the streaming of 14 MeV neutrons through a 0.30-m-diameter duct (length-to-diameter ratio = 2.83) have been calculated using the Monte Carlo code MCNP. The calculated spectra are compared with measured data and data calculated previously using a combination of discrete ordinates and Monte Carlo methods. Comparisons are made at twelve detector locations on and off the duct axis for neutrons with energies above 850 keV and for gamma rays with energies above 750 keV. The neutron spectra calculated using MCNP agree with the measured data within approx. 5 to approx. 50%, depending on detector location and neutron energy. Agreement with the measured gamma-ray spectra is also within approx. 5 to approx. 50%. The spectra obtained with MCNP are also in favorable agreement with the previously calculated data and were obtained with less calculational effort.

Calculated Neutron and Gamma-ray Energy Spectra from 14-MeV Neutrons Streaming Through an Iron Duct

Calculated Neutron and Gamma-ray Energy Spectra from 14-MeV Neutrons Streaming Through an Iron Duct PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Integral experiments that measure the streaming of approx. 14 MeV neutrons through a 0.30-m-diameter iron duct (L/D approx. 3) imbedded in a concrete shield have been carried out at the Oak Ridge National Laboratory. Calculated and measured neutron and gamma-ray energy spectra are compared at sixteen detector locations on and off the cylindrical axis of the duct. The measured spectra were obtained using an NE-213 liquid scintillator detector with pulse-shape discrimination to simultaneously resolve neutron and gamma ray events. The calculated spectra were obtained using a computer code network that incorporates two radiation transport methods: discrete ordinates (with P/sub 3/ multigroup cross sections) and Monte Carlo (with continuous-point cross sections). The two radiation transport methodologies are required to properly account for neutrons that single scatter from the duct to the detector. The calculated and measured outgoing neutron energy spectra above 850 keV agree within 5 to 50% depending on detector location and neutron energy. The calculated and measured gamma ray spectra above 750 keV are also in favorable agreement, approx. 5 to 50%, depending on detector location and gamma ray energy.

Fusion Energy Update

Fusion Energy Update PDF Author:
Publisher:
ISBN:
Category : Controlled fusion
Languages : en
Pages : 68

Get Book Here

Book Description


Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports PDF Author:
Publisher:
ISBN:
Category : Aeronautics
Languages : en
Pages : 1282

Get Book Here

Book Description
Lists citations with abstracts for aerospace related reports obtained from world wide sources and announces documents that have recently been entered into the NASA Scientific and Technical Information Database.

Energy Research Abstracts

Energy Research Abstracts PDF Author:
Publisher:
ISBN:
Category : Power resources
Languages : en
Pages : 660

Get Book Here

Book Description
Semiannual, with semiannual and annual indexes. References to all scientific and technical literature coming from DOE, its laboratories, energy centers, and contractors. Includes all works deriving from DOE, other related government-sponsored information, and foreign nonnuclear information. Arranged under 39 categories, e.g., Biomedical sciences, basic studies; Biomedical sciences, applied studies; Health and safety; and Fusion energy. Entry gives bibliographical information and abstract. Corporate, author, subject, report number indexes.

Nuclear Science Abstracts

Nuclear Science Abstracts PDF Author:
Publisher:
ISBN:
Category : Nuclear energy
Languages : en
Pages : 764

Get Book Here

Book Description


Fusion Technology

Fusion Technology PDF Author:
Publisher:
ISBN:
Category : Fusion reactors
Languages : en
Pages : 306

Get Book Here

Book Description


Comparison of Measured and Calculated Neutron and Gamma-ray Energy Spectra Behind an In-line Shielded Duct

Comparison of Measured and Calculated Neutron and Gamma-ray Energy Spectra Behind an In-line Shielded Duct PDF Author:
Publisher:
ISBN:
Category :
Languages : en
Pages :

Get Book Here

Book Description
Integral experiments that measure the transport of approx. 14 MeV neutrons through a 0.30-m-diameter duct having a length-to-diameter ratio of 2.83 that is partially plugged with a 0.15 m diameter, 0.51 m long shield comprised of alternating layers of stainless steel type 304 and borated polyethylene have been carried out at the Oak Ridge National Laboratory. Measured and calculated neutron and gamma ray energy spectra are compared at several locations relative to the mouth of the duct. The measured spectra were obtained using an NE-213 liquid scintillator detector with pulse shape discrimination methods used to simultaneously resolve neutron and gamma ray events. The calculated spectra were obtained using a computer code network that incorporates two radiation transport methods: discrete ordinates (with P/sub 3/ multigroup cross sections) and Monte Carlo (with continuous point cross sections). The two radiation transport methods are required to account for neutrons that singly scatter from the duct to the detectors. The calculated and measured neutron energy spectra above 850 keV agree with 5 to 50% depending on detector location and neutron energy. The calculated and measured gamma ray energy spectra above 750 keV are also in favorable agreement, approx. 5 to 50%, depending on detector location and gamma ray energy.

Proceedings - Symposium on Fusion Technology

Proceedings - Symposium on Fusion Technology PDF Author:
Publisher:
ISBN:
Category : Controlled fusion
Languages : en
Pages : 714

Get Book Here

Book Description


Proceedings of Technical Meetings

Proceedings of Technical Meetings PDF Author: U.S. Atomic Energy Commission
Publisher:
ISBN:
Category : Nuclear energy
Languages : en
Pages : 62

Get Book Here

Book Description