A Study on New Approaches in Coherent X-ray Microscopy of Biological Specimens

A Study on New Approaches in Coherent X-ray Microscopy of Biological Specimens PDF Author: Klaus Giewekemeyer
Publisher: Universitätsverlag Göttingen
ISBN: 3863950232
Category :
Languages : en
Pages : 226

Get Book Here

Book Description
The use of coherent x rays for microscopic imaging has seen a rapid and ongoing development within the past decade, driven by an increasing availability of highly brilliant and coherent sources worldwide. Accordingly, novel methods have been developed, which replace the microscope‘s objective lens by a numerical reconstruction scheme. The aim of the present work is to study how very recent experimental and algorithmic developments in the field can be implemented towards a highly sensitive and fully quantitative microscopy method for imaging of biological cells. To this end, different experimental approaches are studied, based on coherent far-field as well as near-field diffraction. At first, an application of the novel ptychographic imaging method to single biological cells is presented. In particular, it is demonstrated how weakly scattering biological specimens can be imaged with fully quantitative density contrast. Alongside, a sueccessful extension of the method towards soft x-ray energies is described.In the second part of the work it is shown how x-ray waveguides can be used as a point source for propagation-based microscopy of single cells in the hard x-ray regime. The specifically devised iterative reconstruction scheme allows for full quantitativity and high sensitivity and thus enables an application to single biological cells. The work contains a thorough introduction into the x-ray optical methods applied and aims at a useful and self-contained overview on aspects of signal and Fourier theory relevant for the used numerical propagation schemes.

A Study on New Approaches in Coherent X-ray Microscopy of Biological Specimens

A Study on New Approaches in Coherent X-ray Microscopy of Biological Specimens PDF Author: Klaus Giewekemeyer
Publisher: Universitätsverlag Göttingen
ISBN: 3863950232
Category :
Languages : en
Pages : 226

Get Book Here

Book Description
The use of coherent x rays for microscopic imaging has seen a rapid and ongoing development within the past decade, driven by an increasing availability of highly brilliant and coherent sources worldwide. Accordingly, novel methods have been developed, which replace the microscope‘s objective lens by a numerical reconstruction scheme. The aim of the present work is to study how very recent experimental and algorithmic developments in the field can be implemented towards a highly sensitive and fully quantitative microscopy method for imaging of biological cells. To this end, different experimental approaches are studied, based on coherent far-field as well as near-field diffraction. At first, an application of the novel ptychographic imaging method to single biological cells is presented. In particular, it is demonstrated how weakly scattering biological specimens can be imaged with fully quantitative density contrast. Alongside, a sueccessful extension of the method towards soft x-ray energies is described.In the second part of the work it is shown how x-ray waveguides can be used as a point source for propagation-based microscopy of single cells in the hard x-ray regime. The specifically devised iterative reconstruction scheme allows for full quantitativity and high sensitivity and thus enables an application to single biological cells. The work contains a thorough introduction into the x-ray optical methods applied and aims at a useful and self-contained overview on aspects of signal and Fourier theory relevant for the used numerical propagation schemes.

Cone-beam X-ray Phase Contrast Tomography of Biological Samples

Cone-beam X-ray Phase Contrast Tomography of Biological Samples PDF Author: Matthias Bartels
Publisher: Universitätsverlag Göttingen
ISBN: 3863951344
Category :
Languages : en
Pages : 220

Get Book Here

Book Description
Three-dimensional information of entire objects can be obtained by the remarkable technique of computed tomography (CT). In combination with phase sensitive X-ray imaging high contrast for soft tissue structures can be achieved as opposed to CT based on classical radiography. In this work biological samples ranging from micrometer sized single cells over multi-cellular nerve tissue to entire millimeter sized organs are investigated by use of cone-beam propagationbased X-ray phase contrast. Optimization with respect to contrast, resolution and field of view is achieved by addressing instrumentation, sample preparation and phase reconstruction techniques. By using laboratory sources functional soft tissue within the bony capsule of mouse cochleae is visualized in 3D with unprecedented image quality. At synchrotron storage rings the technique reveals more than 1000 axons running in parallel within a mouse nerve and enables doseefficient three-dimensional cellular imaging as well as two-dimensional imaging at high resolutions below 50 nm.

X-Ray Near-Field Holography: Beyond Idealized Assumptions of the Probe

X-Ray Near-Field Holography: Beyond Idealized Assumptions of the Probe PDF Author: Johannes Hagemann
Publisher: Göttingen University Press
ISBN: 3863953320
Category :
Languages : en
Pages : 152

Get Book Here

Book Description
All images are flawed, no matter how good your lenses, mirrors etc. are. Especially in the hard X-ray regime it is challenging to manufacture high quality optics due to the weak interaction of multi-keV photons with matter. This is a tremendous challenge for obtaining high resolution quantitative X-ray microscopy images. In recent years lensless phase contrast imaging has become an alternative to classical absorptionbased imaging methods. Without any optics, the image is formed only by the free space propagation of the wave field. The actual image has to be formed posteriori by numerical reconstruction methods. Advanced phasing methods enable the experimentalist to recover a complex valued specimen from a single or a set of intensity measurement. This would be the ideal case - reality teaches us that there are no ideal imaging conditions. Describing, understanding and circumventing these non ideal imaging conditions and their effects on X-ray near-field holographic (NFH) imaging are the leitmotifs for this thesis. In NFH the non ideal conditions manifest themselves in the illuminating wave field or probe. The probe generally does not satisfy the canonical assumptions of fully coherent and monochromatic radiation emitted by a point source. The main results of this thesis are compiled as a collection of publications. An approach is shown to reconstruct the probe of a X-ray nano-focus setup by a series of measurements of the probe at varied Fresnel number. The following chapter presents a study concerning the reconstruction efficiency in terms of resolution for near- and far-field based lensless imaging. In the following, the reconstruction scheme for the probe is extended to incorporate the effects of partial coherence in the near field. This enables the recovery of the modal structure of the probe which yields a full description of its coherence properties. Giving up the assumption of temporal stability due to the stochastic pulses, delivered by X-ray free electron lasers, the reconstruction of probe and specimen must be achieved from a single shot. A suitable scheme for this purpose is proposed in this work.

Coherent X-ray diffractive imaging on the single-cell-level of microbial samples

Coherent X-ray diffractive imaging on the single-cell-level of microbial samples PDF Author: Robin Niklas Wilke
Publisher: Göttingen University Press
ISBN: 3863951905
Category :
Languages : en
Pages : 254

Get Book Here

Book Description
Since its first experimental demonstration in 1999, Coherent X-Ray Diffractive Imaging has become one of the most promising high resolution X-Ray imaging techniques using coherent radiation produced by brilliant synchrotron storage rings. The ability to directly invert diffraction data with the help of advanced algorithms has paved the way for microscopic investigations and wave-field analyses on the spatial scale of nanometres without the need for inefficient imaging lenses. X-Ray phase contrast which is a measure of the electron density is an important contrast mode of soft biological specimens. For the case of many dominant elements of soft biological matter, the electron density can be converted into an effective mass density offering a unique quantitative information channel which may shed light on important questions such as DNA compaction in the bacterial nucleoid through ‚weighing with light‘. In this work X-Ray phase contrast maps have been obtained from different biological samples by exploring different methods. In particular, the techniques Ptychography and Waveguide-Holographic-Imaging have been used to obtain twodimensional and three-dimensional mass density maps on the single-cell-level of freeze-dried cells of the bacteria Deinococcus radiodurans, Bacillus subtilis and Bacillus thuringiensis allowing, for instance, to estimate the dry weight of the bacterial genome in a near native state. On top of this, reciprocal space information from coherent small angle X-Ray scattering (cellular Nano-Diffraction) of the fine structure of the bacterial cells has been recorded in a synergistic manner and has been analysed down to a resolution of about 2.3/nm exceeding current limits of direct imaging approaches. Furthermore, the dynamic range of present detector technology being one of the major limiting factors of ptychographic phasing of farfield diffraction data has been significantly increased. Overcoming this problem for the case of the very intense X-Ray beam produced by Kirkpatrick-Baez mirrors has been explored by using semi-transparent central stops.

Biomedical Imaging

Biomedical Imaging PDF Author: Tim Salditt
Publisher: Walter de Gruyter GmbH & Co KG
ISBN: 3110423510
Category : Science
Languages : en
Pages : 437

Get Book Here

Book Description
Covering both physical as well as mathematical and algorithmic foundations, this graduate textbook provides the reader with an introduction into modern biomedical imaging and image processing and reconstruction. These techniques are not only based on advanced instrumentation for image acquisition, but equally on new developments in image processing and reconstruction to extract relevant information from recorded data. To this end, the present book offers a quantitative treatise of radiography, computed tomography, and medical physics. Contents Introduction Digital image processing Essentials of medical x-ray physics Tomography Radiobiology, radiotherapy, and radiation protection Phase contrast radiography Object reconstruction under nonideal conditions

A Dedicated Endstation for Waveguide-based X-ray Imaging

A Dedicated Endstation for Waveguide-based X-ray Imaging PDF Author: Sebastian Kalbfleisch
Publisher: Universitätsverlag Göttingen
ISBN: 3863951018
Category :
Languages : en
Pages : 188

Get Book Here

Book Description


Wave Optical Simulations of X-ray Nano-focusing Optics

Wave Optical Simulations of X-ray Nano-focusing Optics PDF Author: Markus Osterhoff
Publisher: Universitätsverlag Göttingen
ISBN: 3863950542
Category :
Languages : en
Pages : 167

Get Book Here

Book Description
Curved x-ray multilayer mirrors focus synchrotron beams down to tens of nano metres. A wave-optical theory describing propagation of two waves in an elliptically curved focusing multilayer mirror is developed in this thesis. Using numerical integration, the layer shapes can be optimised for reflectivity and aberrations. Within this framework, performance of both existing and currently upgraded synchrotron beamlines is simulated. Using a more theoretical model case, limits of the theory are studied. A significant part of this work is dedicated to partial spatial coherence, modelled using the method of stochastic superpositions. Coherence propagation and filtering by x-ray waveguides is shown analytically and numerically. This comprehensive model is put forward that shall help in development and testing of new algorithms for a variety of imaging techniques using coherent x-ray beams. Advanced simulations accounting for real structure effects are compared to experimental data obtained at the GINIX instrument at the coherence beamline P10 at PETRA III, DESY. This thesis presents results of a collaboration between the Georg-August-Universität Göttingen and the European Synchrotron Radiation Facility (ESRF) Grenoble.

3d virtual histology of neuronal tissue by propagation-based x-ray phase-contrast tomography

3d virtual histology of neuronal tissue by propagation-based x-ray phase-contrast tomography PDF Author: Mareike Töpperwien
Publisher: Göttingen University Press
ISBN: 3863953649
Category :
Languages : en
Pages : 286

Get Book Here

Book Description
Deciphering the three-dimensional (3d) cytoarchitecture of neuronal tissue is an important step towards understanding the connection between tissue function and structure and determining relevant changes in neurodegenerative diseases. The gold standard in pathology is histology, in which the tissue is examined under a light microscope after serial sectioning and subsequent staining. It is an invasive and labor-intensive technique which is prone to artifacts due to the slicing procedure. While it provides excellent results on the 2d slices, the 3d anatomy can only be determined after aligning the individual sections, leading to a non-isotropic resolution within the tissue. X-ray computed tomography (CT) offers a promising alternative due to its potential resolution and large penetration depth which allows for non-invasive imaging of the sample's 3d density distribution. In classical CT, contrast formation is based on absorption of the x-rays as they pass through the sample. However, weakly absorbing samples like soft tissue from the central nervous system give nearly no contrast. By exploiting the much stronger phase shifts for contrast formation, which the sample induces in a (partially) coherent wavefront, it can be substantially increased. During free-space propagation behind the sample, these phase shifts are converted to a measurable intensity image by interference of the disturbed wave fronts. In this thesis, 3d virtual histology is performed by means of propagation-based x-ray phase-contrast tomography on tissue from the central nervous system of humans and mice. A combination of synchrotron-based and laboratory setups is used to visualize the 3d density distribution on varying lengths scales from the whole organ down to single cells. By comparing and optimizing different preparation techniques and phase-retrieval approaches, even sub-cellular resolution can be reached in mm-sized tissue blocks. The development of an automatic cell segmentation workflow provides access to the 3d cellular distribution within the tissue, enabling the quantification of the cellular arrangement and allowing for extensive statistical analysis based on several thousands to millions of cells. This paves the way for biomedical studies aimed at changes in cellular distribution, e.g., in the course of neurodegenerative diseases such as multiple sclerosis, Alzheimer's disease or ischemic stroke.

Phase retrieval problems in x-ray physics

Phase retrieval problems in x-ray physics PDF Author: Carolin Homann
Publisher: Göttingen University Press
ISBN: 3863952103
Category :
Languages : en
Pages : 126

Get Book Here

Book Description
In phase retrieval problems that occur in imaging by coherent x-ray diffraction, one tries to reconstruct information about a sample of interest from possibly noisy intensity measurements of the wave fi eld traversing the sample. The mathematical formulation of these problems bases on some assumptions. Usually one of them is that the x-ray wave fi eld is generated by a point source. In order to address this very idealized assumption, it is common to perform a data preprocessing step, the so-called empty beam correction. Within this work, we study the validity of this approach by presenting a quantitative error estimate. Moreover, in order to solve these phase retrieval problems, we want to incorporate a priori knowledge about the structure of the noise and the solution into the reconstruction process. For this reason, the application of a problem adapted iteratively regularized Newton-type method becomes particularly attractive. This method includes the solution of a convex minimization problem in each iteration step. We present a method for solving general optimization problems of this form. Our method is a generalization of a commonly used algorithm which makes it efficiently applicable to a wide class of problems. We also proof convergence results and show the performance of our method by numerical examples.

Cone-beam x-ray phase-contrast tomography for the observation of single cells in whole organs

Cone-beam x-ray phase-contrast tomography for the observation of single cells in whole organs PDF Author: Martin Krenkel
Publisher: Göttingen University Press
ISBN: 3863952510
Category :
Languages : en
Pages : 238

Get Book Here

Book Description
X-ray imaging enables the nondestructive investigation of interior structures in otherwise opaque samples. In particular the use of computed tomography (CT) allows for arbitrary virtual slices through the object and 3D information about intricate structures can be obtained. However, when it comes to image very small structures like single cells, the classical CT approach is limited by the weak absorption of soft-tissue. The use of phase information, encoded in measureable intensity images by free-space propagation of coherent x-rays, allows a huge increase in contrast, which enables 3D reconstructions at higher resolutions. In this work the application of propagation-based phase-contrast tomography to lung tissue samples is demonstrated in close to in vivo conditions. Reconstructions of the lung structure of whole mice at down to 5 μm resolution are obtained at a selfbuilt CT setup, which is based on a liquid-metal jet x-ray source. To reach even higher resolutions, synchrotron radiation in combination with suitable holographic phase-retrieval algorithms is employed. Due to optimized cone-beam geometry, field of view and resolution can be varied over a wide range of parameters, so that information on different length scales can be achieved, covering several millimeters field of view down to a 3D resolution of 50 nm. Thus, the sub-cellular 3D imaging of single cells embedded in large pieces of tissue is enabled, which paves the way for future biomedical research.